Gamewell-FCI FAAST XT (AAD-9400X) Intelligent Aspiration Detector
File Preview
Click below to download for free
Click below to download for free
File Data
Name | gamewell-fci-faast-xt-aad-9400x-intelligent-aspiration-detector-1852906347.pdf |
---|---|
Type | |
Size | 957.76 KB |
Downloads |
Text Preview
FAAST XT Fire Alarm Aspiration Technology Offers the SLC connectivity via the Velociti protocol Supports 159 FAAST XT devices per loop Provides Very Early Warning Fire Detection as precise 0.00046 ft obscuration five alarm levels and two sensitivity modes to application flexibility Has 3 fan speed settings that allow for maximum cover area and provide savings on current consumption Delivers ultrasonic flow sensing for each pipe inlet and airflow monitoring for precise system health A single device can cover up to 28,800 square feet Combines a dual source optical detection chamber with algorithms to provide high sensitivity with immunity to nuisance conditions Delivers a patented particle separator to remove large particulate ensuring chamber health and the life of the field replaceable filter Converts TCP and Serial modbus for easy integration building management systems Offers easy configuration via USB interface no external needed Supports an onboard Ethernet interface that enables monitoring and email notification Displays an LCD user interface that allows for detailed information and interaction such as the following Active faults Test reset isolate Reset of airflow baseline Precise airflow monitoring Produces configurable air flow fault thresholds Gamewell FCI Intelligent FAAST XT AAD 9400X smoke detectors deliver highly accurate Very Warning Fire Detection over a wide coverage area over the Signaling Line Circuit SLC to the fire control panel via the Velociti protocol This aspirating detector combines advanced particle separation a unique dual source optical smoke detection technol to provide highly sensitive Very Early Warning Fire while providing enhanced immunity to false This technology enables FAAST to accurately incipient fire conditions as early as 60 minutes a fire actually starts when set for Early Warning and Early Warning Fire Detection in applications ranging mission critical to harsh and extreme environments installed FAAST XT device can protect up to 28,800 sq 2,676 sq m in the standard coverage type applications Intelligent FAAST XT Detector can be wired to a new pre existing SLC that is used for transmitting communi directly to a fire alarm control panel via the Velociti without using extra hardware In the Velociti mode AAD 9400X FAAST XT will report back to the fire control panel as an aspirating detector By setting sensitivity levels in PipeIQ the fire alarm control will initiate pre alarm and alarm conditions based on feedback sent from the FAAST XT unit Using the mode up to 159 units can populate one SLC addition to providing a direct connection on the SLC the XT device can be monitored in several different including the following Serial or TCP Modbus Ethernet over a LAN the AAD 9400X is connected to a LAN the FAAST server can email event notification to the appropriate FAAST also communicates alarm and fault via Form C Relays is FAAST intuitive design configuration and software The all in one program can be used do the following Create a pipe network tailored to meet site specific Direct PC connection FAAST onboard USB Configure a FAAST device Monitor an installed device including the following live trending reading of historic reports complimentary download of PipeIQ is available at is a registered trademark of Honeywell International Inc is a registered trademark of System Sensor Inc is a registered trademark of Modbus Organization is a registered trademark of Underwriter Laboratories Inc GAMEWELL FCI are for information only are not intended for installation purposes and are subject to change without notice No responsibility is assumed by Gamewell FCI for their use Clintonville Road Northford CT 06472 1610 USA Tel 203 484 7161 Fax 203 484 7118 by Honeywell International Inc All rights reserved Rev A page 1 of 2 Continued Specifications Continued Configuration Live View Specifications or Ethernet or RS 485 1 illustrates the FAAST XT user interface display 1 Intelligent FAAST XT User Interface Display Fire 1 and Fire 2 10 Particulate levels User Interface consists of 5 Alarm levels Alert Action 1 and Flow and Fault graph Action 2 Information Number Description Sensor Intelligent FAAST XT Fire Aspiration Sensing Technology Information Kit a Instruction Manual Replacement Air Filter Assembly Pipe and Fittings Additional accessory information including part num can be accessed at systemsensor com faast FAAST XT Specifications Specifications Supply Voltage 18 30 VDC Reset Time monitor must be pulled for a minimum of 100 ms sec Reset Operating Current Fan High 465mA 11.2W Med 340mA 8.2W Low 220mA 5.3W High 493mA 11.85W Med 368mA 8.85W Low 248mA 6W Contact Ratings 3.0 A 30 VDC A 125 VAC Ratings Temperature 32 0 to 100 38 Tested to 133 55 Air Range Rating Area Movement Specifications Access Gauge Single Pipe Pipe Length 20 to 140 60 to 95 non condensing sq ft 2,676 sq m ft min 0 1,219 m min in 338 mm in 333 mm in 191 mm 1 inch 2.54 cm cable entry on top bottom and back of unit AWG 2.05 mm max to AWG 0.5 mm min ft 123 m ft 320 m designs must be verified PipeIQ software ft per pipe Pipe Network Outside Pipe Pipe Diameter 0.591 to 0.827 inches 15 21 mm Range to 6.25 Obs ft Obs m to 20.5 Obs m Form C 3 AMP programma latching or non latching inches IPS 25 mm Specifications Log Data Log Log Specifications Services events stored sampling period minute to 1 day custom user entries monitoring E mail address alerts and Serial Modbus SMTP HTTP MODBUS AutoIP NetBIOS NS MODBUS MDI X or Serial RS recipients sel notification Rev A page 2 of 2 Clintonville Road Northford CT 06472 1610 USA Tel 203 484 7161 Fax 203 484 7118