Gamewell-FCI FAAST XT Pro (9440X)

File Preview
File Preview
Click below to download for free

File Data

Name gamewell-fci-faast-xt-pro-9440x-9435028617.pdf
Type PDF
Size 619.95 KB
Downloads

Text Preview

FAAST XT PRO Alarm Aspiration Technology Alarm Aspirating Detectors XT PRO Offers Instantaneous identification of the smoke pipe smoke Employs MOS Sensor Technology to identify the inlet Provides Very Early Warning Fire Detection as precise 0.00029 ft obscuration five alarm levels and three sensitivity modes to application flexibility User configurable 3 speed fan allowing for maximum area or minimizing on current consumption Produces an ultrasonic flow sensing for each pipe inlet chamber airflow monitoring for precise system information A single device covers up to 28,800 square feet Has dual source optical detection chamber with algorithms provide high sensitivity with immunity to nuisance conditions Patented particle separator removes large non fire par ensuring the chamber health and extending the of the field replaceable filter Monitors TCP and Serial Modbus for an easy integra with the Building Management Systems Easy configuration via USB interface no external power Supports an on board Ethernet interface to enable the Remote Monitoring Configuration Web Server E mail notifications Gamewell FCI FAAST XT PRO Aspirating Smoke deliver a Very Early Warning Fire Detection that a unique pipe identification technology designed to the accuracy of smoke detection in large spaces FAAST XT Pro Aspirating Smoke Detector combines particle separation with a unique dual source smoke detection technology It is used to provide sensitive Very Early Warning Fire Detection while providing an enhanced immunity to false This innovative technology enables the FAAST XT to accurately detect incipient fire conditions as early as minutes before a fire actually starts The advance feature occurs when the detector is set for Early and Very Early Warning Fire Detection in applica ranging from mission critical to harsh and extreme MOS Sensor Technology detects the smoke related and provides instantaneous identification of the first drawing smoke into the smoke chamber thus provid an even more accurate location of the source of installed FAAST XT Pro device can protect up to sq ft 2,676 sq m in the standard coverage type and it can be monitored in several different including the following Serial or TCP Modbus Ethernet over a LAN or a direct connection FAAST XT on board USB it is connected to a LAN the FAAST XT Pro email can provide email event notification to appropriate The FAAST XT Pro also communicates alarm notifications via form C relays PipeIQ is the FAAST XT Pro intuitive design con and monitoring software The all in one program be used to create a pipe network tailored to do the fol Meet the site specific requirements Configure a FAAST XT Pro device Monitor an installed device including monitoring live and the reading of historic reports complimentary download of PipeIQ software is available www gamewell fci com esd is a registered trademark of Honeywell International Inc is a registered trademark of System Sensor Inc is a registered trademark of Modbus Organization is a registered trademark of Underwriter Laboratories Inc GAMEWELL FCI are for information only are not intended for installation purposes and are subject to change without notice No responsibility is assumed by Gamewell FCI for their use Clintonville Road Northford CT 06472 1610 USA Tel 203 484 7161 Fax 203 484 7118 by Honeywell International Inc All rights reserved Rev A page 1 of 2 Continued Multi lingual LCD user interface allows for detailed information and interaction such as the following Reset of Airflow Baseline Precise Airflow Monitoring Active Faults Test Reset Isolate Has a configurable air flow fault thresholds and verifica period Contains a convenient wiring compartment The Status at a glance provides immediate alarm fault airflow status XT User Interface Display 1 illustrates the FAAST XT User Interface Display 1 FAAST XT User Interface Display Fire 1 Fire 2 User Interface consists of the following five Alarm Alert Action 1 Action 2 addition the User Interface includes the following 4 Pipe Alarm Indicators 10 Airflow Indicators LCD 10 Particulate Levels 4 Fault Indicators Information Number Description Sensor Conventional FAAST Fire Aspiration Sensing Technology Pipe and Fittings Additional accessory information including part can be accessed at www gamewell fci com esd XS Specifications Specifications Supply Voltage 18 30 VDC Reset Time Reset Current Current Contact Ratings 3.0 A 30 VDC monitor must be pulled for a minimum of 100 ms second High 565mA 11.2W Med 440mA 8.2W Low 320mA 5.3W High 593mA 11.85W Med 468mA 8.85W Low 348mA 6W A 125 VAC 8 form C AMP programmable latching non latching Tested to 133 55 20 to 140 60 to 95 non condensing to 6.25 Obs ft Obs m to 20.5 Obs m sq ft 2,676 sq m ft min 0 1,219 m min Specifications Temperature 32 0 to 100 38 Air Range Range Rating Area Movement Specifications Access Gauge Single Length 338 mm 333 mm 191 mm 1 inch 2.54 cm cable entry holes the top bottom and back of the unit AWG 2.05 mm max to 24 AWG mm min ft 123 m other three pipes Pipe Length 1050 ft 320 m all designs must be within PipeIQ software Pipe Pipe inches IPS 25 mm to 0.827 inches 15 21 mm form C 3 AMP programmable or non latching Specifications Log Data Log Configurable sampling period 1 minute events stored 1 day custom user entries monitoring six email address TCP and Serial Modbus Log Specifications Services DHCP SMTP HTTP MODBUS TCP NetBIOS NS Serial MODBUS MDI X or Serial RS 485 recipients selectable notifications Configuration Live View Logs Specifications or Ethernet or RS 485 Rev A page 2 of 2 Clintonville Road Northford CT 06472 1610 USA Tel 203 484 7161 Fax 203 484 7118

Related Files