Gamewell-FCI FC-72-DL Series Releasing Panels

File Preview
File Preview
Click below to download for free

File Data

Name gamewell-fci-fc-72-dl-series-releasing-panels-7928531406.pdf
Type PDF
Size 637.75 KB
Downloads

Text Preview

DESCRIPTION FC 72 DL series Deluge and Preaction System Con Panel provides the basic functions and features of a stan FC 72 fire alarm control less the city box trip feature In the FC 72 DL series contains circuitry that can su and energize a solenoid valve or water control deluge upon receipt of an alarm together with a valve discon switch for test or service use FC 72 DL is equipped for single zone operation while FC 72 DL2 contains a second zone suitable for monitor supervisory devices FC 72 DL series is housed in a surface mounted duty 16 gauge steel enclosure finished in textured measuring 19.38 high 15 wide and 4 deep 49.23 x x 10.16 cm controls contain two sets of dry Form alarm actu contacts and a supervised output for a remote annuncia As an optional feature the panel can contain a set of dry trouble actuated contacts releasing device modules may be used to provide ad releasing circuits within a common enclosure FCI the addition of APS 6 auxiliary power supplies additional RDF modules initiating circuit s can be wired either Class A Style or Class B Style B The notification appliance circuits can wired Class A Style Z or Class B Style Y Factory Mutual Research Corp only approves A initiating circuits and does not approve the use of detectors with this control FC 72 DL series is UL Listed for use with any UL compatible release solenoid max 1 per circuit rated 24 VDC or less UL testing has determined that the Model LV2LBX25 solenoid valve is compatible APPROVALS Std 864 Series AND PREACTION SYSTEM CONTROL PANEL UL Listed as Suitable for Releasing Service Factory Mutual Research Approved an Automatic Release for Preaction Deluge Sprinkler Systems Power Limited Output for Solenoid valve Common Alarm Dry Contacts Fused Filtered and 24 VDC Smoke Detector Auxiliary Power Outputs Temporal Pattern per ANSI S3.41 Ammeter and Voltmeter optional Factory Assembled and Tested FC 72 DL series is approved by Factory Mutual Research for use with solenoids in Factory Mutual Control Groups 2 and 3 Solenoid Groups A B and C while the RDF module is approved for Control Panel 1 Solenoid Group A as follows GroupA Skinner Model LV2LBX25 24 VDC 1 2 inch 1.27 cm NPS 1 2 inch 1.27 cm orifice ASCO Model R8210A107 T8210A107 or 8210A107 24 VDC 1 2 inch 1.27 cm NPS Group B inch 0.95 cm orifice Group C Star Sprinkler Corp Solenoid P N 5550 24 VDC part of Model D Deluge Valve are provided for information only are not intended to be used for installation purposes and are believed to be accurate However no responsibility is assumed Fire Control Instruments Inc for their use Specifications subject to change without notice All Rights Reserved Southwest Park Westwood MA 02090 USA TEL 781 471 3000 FAX 781 471 3099 ISO 9001 Certified Company 1.4 Control Instruments Inc RELAY Cut when remote zone annunciator Model RZA is used Denotes supervised wiring Denotes option or accessory Transfer Relay and Signal Relays Relay Relay 3.9K 1 2 watt for Class B Style B See manual page 7 Sec B for Class A Style D Main supply circuit Input 120 VAC 60 Hz 2.0 A Non Power Limited Circuit K3 NO 24 VDC nom 4.0 amp battery circuit Input 24 VDC nom Non Power Limited Circuit Output 27.2 VDC 0.90 amp max Factory Mutual requires 90 hours of standby for preaction and deluge systems Circuit Supervisory current 24 VDC nom 035 amp maximum Power Limited circuit Notification Appliance Circuit Output 24 VDC nom 0.5 amp maximum Power Limited circuit Annunciator circuit 24 VDC nom 100 amp maximum Power Limited circuit Release output 24 VDC nom fused 4 amp Non Power Limited Circuit Main power limiter fuse F8 permanent Applies only to FC 72 DL2 for the release output A C supply circuit and standby battery circuit COMPLETE INFORMATION SEE INSTRUCTION MANUAL 9000 0009 of 2

Related Files