Gamewell-FCI FC-73 9020-0523
File Preview
Click below to download for free
Click below to download for free
File Data
Name | gamewell-fci-fc-73-9020-0523-7384169502.pdf |
---|---|
Type | |
Size | 1.04 MB |
Downloads |
Text Preview
www firecontrolinstruments com The FC 73 Series Fire Alarm Control is a proven versatile conventional unit which meets the requirements NFPA Standard 72 for Central Station Premises Auxiliary Remote Proprietary Supervising Station Fire Systems It is listed to UL Stan 864 inherently power limited and has necessary circuitry to meet the UL tran immunity requirements The system is housed in a heavy duty enclosure finished in red with pan displaying the status of vital functions surface mounted enclosure with its appearance 4 inch depth is designed blend with any environment The cabi can house up to 7AH batteries while system power supply can maintain of up to 33 AH batteries enclosed the separately available BC 1R 1100 The many features of the FC 73 pro a cost effective approach to system and allow a great degree of flex in one enclosure The panel provides 10 Class B Style B or five 5 Class Style D zones expandable to twenty Class B or ten 10 Class A zones the addition of the ZDM FC73 Mod The FC 73 also provides four 4 Class Style Y or two 2 Class A Style Z appliance circuits Standard on all FC 73 control panels are City Master Box output Polarity Rever signaling connections and Integrated The combination of a conventional alarm control panel with a micropro design allows for programming of unique features such as time limit programmed verification pre alarm and cross zoning Individual zones be assigned specific outputs and zone such as alarm supervisory or In addition up to eight 8 se notification appli circuit output patterns are available alternate styles of warnings Program is achieved through the LCD FC73 module or through the Field Program FCP 73 of vital components modules switches and standby batter is provided The integral Digital Alarm Communica Transmitter supports all standard re formats including 3 1 1400 Hz cid 127 3 1 2300 Hz SK 4 2 1400 Hz cid 127 SIA 8 SIA 20 Contact ID Optional modules include an LCD remote a zone expander module used expand the system and a status dis module which provides outputs and functions for each zone as well as access Zone Disconnect Switches up to six 6 Remote LCD Displays Supports up to six 6 Remote LED Annunciators Integral Digital Communicator Transmitter Expandable to Twenty 20 Class B or Ten 10 Class A Zones Field Programmable Configuration Eight 8 Selectable Programmable Output Patterns Including Temporal Pattern Output per ANSI S3.41 Test Capability provided by the LCD FC73 optional Remote Annunciator Programmable Alarm Verification and Cross Zoning Four 4 Class B or Two 2 Class A Notification Appliance Circuits Six 6 Amp power Supply Three integral progammable relays Provides Municipal Circuit or Reverse Polarity output Reverse Polarity or Municipal Circuit output ALARM PANEL ISO 9001 Company ISO 9001 Company ISO 9001 Company ISO 9001 Company ISO 9001 Company are provided for information only and not intended to be used for installation purposes are believed to be accurate However no respon is assumed by Fire Control Instruments Inc for use Specifications subject to change without 2001 All Rights Reserved 9020 0523 Rev B 1 of 4 EXPANDER ZDM FC73 The ZDM FC73 Zone Expander provides the FC 73 ten 10 additional Class B Style B or five 5 A Style D initiating circuits Mounts in main or in FC 2190 Accessory Cabinet C D C D C D C D C D DISPLAY MODULE FC 5280 The FC 5280 Status Display Module provides out and control functions for remote annunciation of trouble and supervisory indications for each The system can supervise up to eight 8 mod The FC 5280 has ten 10 outputs for alarm and 10 for trouble annunciation These outputs are low become negative when activated Each can provide up to 0.100 amp current with a of 0.700 amp available The module has four 4 C relays that can be wired to operate with any the outputs The FC 5280 can be used to interface an LED annunciator It can be programmed to alarm and trouble status for Zones 1 10 11 20 or system status outputs The FC 5280 mounts the FC73 cabinet C2 A1 A2 A3 A4 A5 A6 A7 A8 A9 C4 BASIC FC 73 ASSEMBLY TIP RING TIP RING TIP CONTROL ALARM CONTROL FC 73 ACCESSORIES The LCD FC73 supervised remote annunciator performs system operations It can be used for programming and access to the Walk Test feature and trouble and information The control panel can support up to six annunciators Total distance is up to 3000 feet away two pair of two conductor wire ALARM ANNUNCIATOR LCD FC73 are provided for information only and are not intened to be used for installation purposes and are believed to be accurate no responsibility is assumed by Fire Control Instruments Inc for their use Specifications subject to change without notice 2001 All Rights Reserved Southwest Park Westwood MA 02090 USA cid 127 Tel 781 471 3000 cid 127 Fax 781 471 3099 cid 127 www firecontrolinstruments com CONTROL INSTRUMENTS 9020 0523 Rev B Page 2 of 4 Style B or 5 Style D Device Circuits Voltage 25.5 VDC Circuit Resistance 50 Ohms Alarm Current for all Circuits 1.0 amp Current per Zone 0.003 amp Current per Zone 0.095 amp Supervised with 3.9KW EOL required for Style D circuits DACT Connections TIP 1 2 3 4 5 6 7 8 9 1 2 3 4 11 12 14 16 17 18 19 Programmable Form C Relay Outputs amps 24 VDC 24 VAC inductive amps 24 VDC resistive power limited Circuit Output Polarity Output Style Y or 2 Style Z Appliance Circuits Supervised 3.9KW EOL resistor Style Y only amps max out o