Gamewell-FCI FireVAC IV Emergency Voice Evacuation

File Preview
File Preview
Click below to download for free

File Data

Name gamewell-fci-firevac-iv-emergency-voice-evacuation-9562107834.pdf
Type PDF
Size 766.34 KB
Downloads

Text Preview

Audio Systems IV Voice Evacuation System FireVac is a fully automatic combination fire alarm and emergency voice system When it is combined with a Gamewell FCI fire alarm control panel provides automatic and manual alarm signaling in compliance with the National Alarm Code NFPA 72 FireVac IV is ideal for installations requiring voice evacuation in areas such as cafeterias auditoriums etc The power output available from the FireVac IV a cost effective solution to smaller voice evacuation applications such as assisted facilities dormitories motels and hotels etc unit provides 50 Watts of audio power at either 25 VRMS or 70 VRMS requires the FireVac IV offers eight field selectable tones built in as well as an internal for voice paging The system also has three programmable messages first and second messages may be changed via software download and can up to 32 seconds long The third message can be recorded via the system own microphone and can record up to 49 seconds long FireVac IV is fully supervised for opens short circuits and ground faults on the appliance circuit The system amplifier is continuously supervised In the amplifier is protected from damage by the short circuit disconnect built into the speaker circuit optional FVIV ZS provides the capacity to split the available 50 watt power output four separate independently activated speaker circuits Each speaker circuit its own switch for manual activation as well as an All Call switch to turn on all four at once It mounts inside the main FireVac IV cabinet a further option the FVIV RM Remote Microphone station is available in its own It can be mounted up to 5,000 feet away and connects to the FireVac over four conductor 18 AWG wire BENEFITS Compatible with any Listed fire alarm panel Provides 50 watt power 25 or 70.7 optional Class A Power operation Integral message Eight DIP switch tones Optional FVIV ZS ANSI Cadence four Style Y or Class A or B speaker Auxiliary audio input Form trouble and relay outputs Remote microphone for all call Single channel March Code California Code Steady Alert Tone Hi Lo ANSI Whoop Continuous Whoop IV Operation operation of a fire alarm initiating device i e detectors manual stations water flow etc connected to the fire alarm control will cause either a reverse polarity signal or a dry closure to be sent to the FireVac If the FVIV ZS is installed the fire alarm control will also provide up to four normally open dry outputs that will close to activate the speaker circuit In response the FireVac do the following Sound an alarm tone DIP switch selectable over speaker circuit s Produce a recorded message that will play in with the selected tone both tone and pre recorded message and voice commands from the local or remote FireVac provides two separate messages that be field configured using the optional 7780 Modules FVIV ZS 1 shows the optional FVIV ZS speaker circuit 2 FVIV X70 FVIV X70 optional module is used to convert the speaker circuit voltage output from 25 VRMS 70 VRMS This voltage output is useful in situations the speakers circuits must run for longer Speakers at 70 VRMS are not Class A Power and must be separated from Class A Power circuits by at least 1 4 inch 3 illustrates the FVIV RM remote microphone 1 Optional Modules FVIV ZS FVIV ZS provides four separate individually speaker circuits that is an ideal solution for that require zoned speaker circuit The FVIV ZS features a switch for the activation of each speaker circuit as well as an switch for paging interface with the fire alarm control panel is through normally open relays provided by the control panel The FVIV ZS responds to closures its input terminals to activate the appropriate circuit 3 FVIV RM FVIV RM Remote Microphone Station enhances of the system by providing voice paging from remote location up to 5,000 feet away Only four wires 18 AWG minimum are required between the and the FVIV RM The FVIV RM is fully by the FireVac Simply key the to activate the Fire Vac in an to page over all speakers FVIV RM is shipped complete with its own cabinet dimensions of 10 1 4 H x 10 3 8 W x 3 1 8 D Information FireVac Emergency Voice Evacuation 50 watts Alone FVIV 50 ZS Emergency Voice Evacuation 4 channel 50 watt total FVIV RM Remote Microphone Station per system FVIV X70 Line Transformer converts 25 speaker circuit s to 70 VRMS FVIV ZS FVIV B450 Zone Splitter 4 Speaker 7780 Programming Software to or remove recorded messages 4 illustrates the FireVAC IV with the FVIV RM assembly 4 FireVac IV Assembly IV Technical Specifications Voltage VAC 60 Hz 1.2 amp or VAC 50 Hz 0.607 amp Temperature 32 to 120 F 0 to 49 C Humidity to 85 at 86 F 30 When you order specify voltage requirements Current IV amp amp amp amp Alarm Relays Surface Mount 26 1 4 x 14 1 2 x 4 67 x 36.3 x 8.8 cm Mount 24 3 4 1 2 7 16 Weight 37 lbs 16.78 kg AND HUMIDITY RANGES amp amp circuits active amp amp A 30 VDC resistive system meets NFPA requirements for operation at 0 49 120 and at a relative humidity 93 2 non condensing at 32 2 90 3 the useful life of the system s standby batteries the electronic components may be adversely affected extreme temperature ranges and humidity Therefore it recommended that this system and its peripherals be in an environment with a normal room of 15 27 80 FireVAC IV is designed to comply with the following Standard 864 9th Edition LISTINGS AND APPROVALS listings and approvals apply to the mod specified in this document In some cases cer modules or applications may not be listed by approval agencies or listing may be in pro Consult the factory for the latest listing sta Listed S1949 7300 1703 0168 1000 Certification a complete listing of all approvals and please visit IV and Gamewell are registered trademarks Honeywell International Inc is a registered trademark Underwriter Laboratories document is not intended be used for installation We try to keep our information up to and accurate We cannot all specific applications anticipate all requirements specifications are subject to without notice more information more about Gamewell FCI FireVAC IV and other products by visiting www Gamewell FCI com Gamewell FCI Clintonville Road CT 06472 1610 F 09 17 Honeywell International Inc

Related Files