Gamewell-FCI FireVac IV Voice Evacuation System Specification
File Preview
Click below to download for free
Click below to download for free
File Data
Name | gamewell-fci-firevac-iv-voice-evacuation-system-specification-3946251780.pdf |
---|---|
Type | |
Size | 652.40 KB |
Downloads |
Text Preview
FireVac IV Voice Evacuation System Specification No 9020 0511 1.8 June 3 2004 Control Instruments Inc Southwest Park Ma 02090 2001 Rights Reserved in the USA ONE GENERAL INCLUDES INCLUDED components for a complete Voice Evacuation System hardware and software necessary to comply with the operation detailed in this system shall maintain the following listings and or approvals from the agencies UL Laboratory 70 72 101 864 1481 1638 1971 Local State Building Codes Electrical Code 1996 Edition Fire Alarm Code 1996 Edition Safety Code Standard for Fire Alarm Control Equipment Standard for Power Supplies for Fire Protective Signaling Standard for Visual Signaling Appliances Standard for Signaling Devices for the Hearing Impaired DESCRIPTION voice evacuation panel shall be compatible with the FACP to which it is attached The shall contain a voice evacuation system to supervise and operate UL listed voice speakers The system shall have a built in UL listed power supply The system be capable of supporting an optional UL listed zone splitter that can be housed in the voice control cabinet In addition the system will issue pre recorded voice commands for purpose of evacuation The system must support a minimum of two pre recorded and have the capability of adding application specific messages through the use of PC The voice evacuation system shall have the ability to provide a supervised for the purpose of audible local instructions that will override the pre recorded The system shall contain a dead front panel inside the enclosure to protect the from exposure by the operator and to protect the operator from hazardous voltages Data Provide data for each system component and software module Drawings diagram showing voice evacuation system unit locations and conductors connection points of all voice evacuation system units system graphics indicating monitored systems data connected and calculated and notations system configuration with peripheral devices batteries power supplies diagrams and description and sequence of operation of operating user and application software Record Documents Record actual locations of control components shop drawings to reflect actual installation and operating sequences data specified in Submittals in final Record Documents form and Maintenance Data interconnection wiring diagrams complete field installed systems with identified and system components and devices illustrations and step by step procedures indexed for each operator function Submit manufacturers warranty and ensure forms have been filled out in Owners name registered with manufacturer ASSURANCE Qualifications Company specializing in manufacturing the fire alarm life safety with minimum 10 years documented experience Qualifications Company specializing in performing the work of this section with 5 years documented experience equipment supplied for this project shall be new and unused except for existing equipment reused equipment shall be designed for continuous duty EVACUATION SYSTEM HARDWARE a complete and electrically supervised voice evacuation system voice evacuation system shall have a 50 watt supervised amplifier with a built in Digital Repeater and a supervised microphone The voice evacuation system shall have two inputs one triggered by reverse polarity and one by supervised dry contact trigger The evacuation system shall have a speaker output line voltage of 25 VRMS with provisions for a VRMS option This speaker output must also be field selectable for class A or class B The alarm inputs shall be programmable to provide one of two prerecorded audio The voice evacuation system shall provide for field programming of custom messages the built in microphone line level input of an audio message and the downloading of message from a PC voice evacuation system shall have a built in UL approved power supply The system shall up to 18 amp hour batteries to be housed in the main cabinet larger batteries up to 33 will require the use of a UL listed battery cabinet The power supply shall be power and rated to operate the voice evacuation system under normal operation including battery current for the use of up to 33 amp hour backup batteries per UL specifications at full current draw in order to maintain system integrity voice evacuation system shall have an optional zone splitter capable of dividing the speaker of the amplifier into 4 class B or 4 class A outputs Selection of the zones shall be via toggle switches on the splitter or inputs from the FACP The zone splitter shall have an all call toggle switch that when activated will turn on all speaker zones regardless of individual toggle switch settings Each speaker zone of the zone splitter shall be capable of the full output of the amplifier The zone splitter shall maintain supervision of the circuits control shall be equipped with two auxiliary relays one shall operate on alarm and the other on The relays shall continue indicating until the condition is cleared The system shall also capable of passing a trouble condition back through the FACP notification output in lieu of the relay system shall contain the following visual indicators Speaker Trouble Alarm Microphone Dry Contact Input Trouble Auxiliary Device Trouble and Power design and commissioning for a complete system all components in accordance with manufacturer instructions control units and other hardware in position on permanent walls where not subject to vibration or moisture Leave adequate space for access all features of software to specified requirements and appropriate to sequence of Power up and test all system devices to ensure correct operation AND CERTIFICATION connected hardware and programmed software functions shall be tested to conform to the technician certified by the National Institute for Certification in Engineering Technologies shall conduct final checkout of all system functions The technician shall have current of at least level 2 in the field of Fire Protection Engineering Technology OF SECTION