Gamewell-FCI Flex 620 Coventional Control Panel
File Preview
Click below to download for free
Click below to download for free
File Data
Name | gamewell-fci-flex-620-coventional-control-panel-3417098625.pdf |
---|---|
Type | |
Size | 617.95 KB |
Downloads |
Text Preview
Description Flex 620 is one of several control panels that make up 600 Series of control panels The Flex 620 is a fire alarm control panel FACP that can be to monitor and control conventional hardwire zones the maximum application flexibility It can be adapted to either a complex retrofit installation or a new providing up to 128 conventional hardwired I O With the addition of the SmartNet Network the Flex application can include analog addressable panels in same network The interactive Operator Display uses prompting to ease both user operation and programming Alphanumeric Display and keypad simplify field which can also be accomplished via a PC link Flex 620 offers all the features of today most advanced safety systems Through individual selection of individual modules the system engineer can customize the control to maximize efficiencies based on the application The automatically senses the system configuration to ensure modules are correctly positioned to speed installation and trouble shooting of the most complex system Flex 620 software allows the system to be customized to specific application requirements such as cross zoning verification and extensive input output relationship Flex 620 housing was designed to be both aesthetically and functionally sound The dead front construction designed to allow routine maintenance of the system without about disturbing the I O Modules Access to system keys is limited by multiple levels of password to prohibit unauthorized use An optional locked door GD 4 GD 8 can be added for additional The cabinet has been designed with permanent strips for ease of installation and service Display Flex 620 Operator Display is the center of all user to the system The display supplies all the necessary and annunciation points to maintain and monitor the Alarm Supervisory and Trouble conditions are all on the Operator Display by dedicated LEDs and internal sounder The Acknowledge Reset and Signal keys are easily identified 620 Control Listed CSFM FM MEA City of Chicago High Approved input circuits expandable from 4 128 zones TM Self programming logic modular character 4 line display character user labels default response for increased survivability Event history log or front panel programming protected annunciator remote display and remote printer One man selectable input walk test signaling mode settings compatible Front construction network compatible non volatile program storage Rev 1202 1 1 Acknowledge key acknowledges all off normal conditions silences the internal sounder Reset key is used to return the control panel to the idle after an alarm condition has been cleared Trouble that have been cleared will automatically return the panel to the idle mode if the problem has been Trouble conditions that have been acknowledged resound the internal sounder if the condition is not corrected a programmed time period Signal Silence key can be used to deactivate notification This function can be modified by user programming only operate after a specified time period to insure that the are not turned off before the cause has been are three 3 additional programmable switches available control application specific operations such as manual warning or building evacuation 160 character LCD display and LED annunciation is also for AC Power Pre Alarm Alarm Trouble Supervisory Keys for programming and bypass functions along with for active and trouble conditions are provided for the Connection and two signal circuits which are part of the Control section 620 Common Control Flex 620 Common Control section comprises the heart of system The Common Control section houses the main and all system memory as well as providing local and communications and supervision The common control the common system relays two signal circuits city and optional RS 232 port All interaction with the Common section is accomplished through the Operator Display four relay circuits provide for control of auxiliary functions relays are controlled by the main CPU The relays are at 10 Amp 24 VDC notification appliance circuits NAC are provided NACs can provide a steady or coded output All circuits power limited per NEC 760 and UL864 For coded power wiring applications the Main Power Limiting MPL must be used for signal circuits Input Module Conventional Input Module CIM 4 8 CS 2026 occupies 1 bay and provides either 4 or 8 hardwire input circuits monitoring of conventional detectors and contact type This module monitors and reports to the CPU each analog status in order to distinguish between detectors contact devices and to determine if two or more detectors in alarm Each Input module uses one slot in the MPU bus is supplied with its own display module Display module provides LED annunciation of alarm and conditions and has a switch per circuit for programming bypass functions The display has provisions for user custom labels per circuit normal alarm and supervisory functions the input can be programmed for Remote Acknowledge Reset Silence and Release Abort switches Circuits can be for either style B C D and E service and are capable of normally closed devices Signal Module 600 Series Universal Signal Module USM 4 8 CS 2024 one 1 bay and is a multi functional output module is available in 4 or 8 circuit increments Modules via the MPU bus and require 1 expansion slot The USM can be configured as 24VDC signaling circuits are programmed in two circuit increments making it to perform all four functions with a single module circuits can provide a steady or coded output All circuits power limited per NEC 760 and UL864 Signal circuits can installed using either style Y or Z wiring modules are supplied with their own display module provides LED annunciation of activation and trouble and has a switch per circuit for programming and functions The display has provisions for user defined labels per circuit Supply 600 Series Power Supply MPS 8 furnishes system and signaling power The integral 8 Amp supply is with a battery charger capable of maintaining the power source The Power Supply is monitored by main CPU to ensure that adequate power levels are The power supply design allows for high efficiency still providing precise power output battery charger is capable of operating with lead acid The charger is sized to maintain up to 60Ah Batteries charger automatic high rate circuitry is monitored by the CPU Multiple auxiliary power supplies APS 8 may be to the system when additional power is required only USM module Rev 1202 1 2 Flex 620 Conventional Control Panel is designed for those to large projects that require state of the art conventional life safety systems The embedded CPU offers users reliability without sacrificing flexibility or value complete line of 600 Series I O modules can be to offer system designs and lay outs which maximize and economies without sacrificing quality or The Flex 620 with Gamewell complete line of devices provide the foundation for system design 620 optional RS 232 output expands the system and control capability Annunciators can be added to display system activity control The serial annunciator drivers are an ideal interface graphic annunciators alphanumeric display RAN2 RC can also be used for status and control The alphanumeric display is to communicate over the serial communications It is a 160 character display and provides remote keys See CS 2025 and CS 2027 for complete annunciator de