Gamewell-FCI Flex GF506D Pre-action Deluge Control Panel
File Preview
Click below to download for free
Click below to download for free
File Data
Name | gamewell-fci-flex-gf506d-pre-action-deluge-control-panel-6831970524.pdf |
---|---|
Type | |
Size | 659.49 KB |
Downloads |
Text Preview
Conventional Control Panels GF506D Deluge Control Panel Flex GF506D is a six zone fire alarm control panel FACP that is used for single dual hazard deluge and pre action applications The Flex GF506D provides fire detection It also offers signaling and protection for commercial and institutional buildings that require water based releasing The Flex is compatible with System Sensor i3 detectors i3 detectors are conventional smoke detectors that transmit a maintenance signal to the FACP that indicates the need for cleaning It also transmits a signal when the ambient temperature falls below the detector of approximately 45 7.22 In addition the Flex GF506D fire alarm control is compatible with the following conventional input devices two wire and four wire smoke detectors waterflow devices and tamper switches pull stations a complete listing of compatible devices refer to the Gamewell FCI Device Document P N 52195 are four outputs that are programmable as NACs Notification Appliance or releasing circuits Three programmable Form C relays factory for Alarm Trouble and Supervisory and the 24 VDC special application and non resettable power outputs are included on the main circuit board Flex GF506D supervises all wiring AC voltage battery charger and battery level activation of a compatible smoke detector or any normally open fire alarm device will do the following turn on audible and visual signaling devices light as an indicator display alarm information on the panel LCD activate the FACP alarm relay sound the piezo sounder at the FACP operate an optional module used to notify a remote station or initiate an auxiliary control other normally open contact devices BENEFITS Flex GF506D Listed to UL Standard 9th Edition IBC Seismic Certified Designed for sprinkler NFPA 13 15 16 Dual hazard operation Adjustable waterflow timer and soak timers Cross zone double capability Six programmable B Class B IDCs Device with optional A wiring System Sensor i3 series detectors Four programmable Y Class B output special ANN BUS for Outputs power with A Style Z option System Sensor Cooper Wheelock Gentex Faraday Amseco Three programmable relays 7.0 amps total 24 VDC current Resettable and non output Built in Programmer Piezo sounder for trouble and to optional to 8 total of any of following GFANN 80 Remote LCD Annunciator GFANN RLY Relay Module GFANN LED Annunciator Module 80 character LCD back lit Real time clock w daylight time control History Log with 256 storage 24 volt DC operation Low AC voltage sense for the Releasing circuits or NACs programmable the following Silence Inhibit Auto Silence Strobe Synchronization Selective Silence horn strobe mute Temporal or Steady Signal Silenceable or Non silenceable Release Stage Sounder Disable Enable control input zone and zone Extensive transient Automatic battery with charger Optional Dress Panel red Optional Trim Ring TR red used for semi mounting on the cabinet Optional CAC 5X Class Converter Module for and IDCs Optional 4XTMF Box Module Optional Digital Alarm 411 411UDAC and Software programming software offers the following features Custom English labels per point may be manually entered or from an internal library file Three programmable Form C relay outputs Pre programmed and custom application templates Continuous fire protection during online programming at the front Program Check automatically catches common errors not linked to zone or input point Interface user interface features are listed below Integral 80 character LCD display with back lighting Real time clock calendar with automatic daylight savings System Reset lamp test Drill AC Power green Alarm Silenced yellow Discharge red ANN Bus for connection to remote annunciators Audible or silent walk test capabilities Piezo sounder for alarm trouble and supervisory and Indicators panel provides the following LED Indicators Fire Alarm red Supervisory yellow Trouble yellow Buttons Acknowledge Alarm Silence Information Power TB1 AC Power TB1 for each panel is listed below 120 VAC 50 60 Hz 2.3 amps size minimum 14 AWG 2.0 mm2 with 600V insulation non power limited sealed lead acid only J12 The Battery for sealed lead only J12 specifications are listed below Charging Circuit Normal Flat Charge 27.6 VDC 1.4 Supervised non power limited Charger Capacity 26 Amp Hour battery two 18 Amp batteries can be housed in the FACP cabinet Larger batteries separate battery box such as the BB 26 or BB 55 Battery Size 7 Amp Hour Device Circuits TB4 and TB6 Initiating Device Circuits for TB4 and TB6 specifications are listed Alarm Zones 1 5 on TB4 Alarm Zone 6 on TB6 Supervised and Class A power limited circuitry Style B Class B wiring with Style D Class A option Operating Voltage Nominal 20 VDC Current 15 mA minimum Circuit Current 40 mA max Loop Resistance 100 Ohms Resistor 4.7KOhms 1 2 watt PN 71252 2 of 4 9021 60466 E 10 04 2018 Standby Current 4 mA a list of compatible devices refer to the Gamewell FCI Device Document P N 52195 Appliance and Releasing Circuit s TB5 and TB7 notification appliance and releasing circuits for TB5 and TB7 are listed below Four Output Circuits Style Y Class B or Style Z Class A with optional converter module Strobe synchronization Special Application power Supervised and Class A power limited circuitry Operating Voltage Nominal 24 VDC Signaling Current 7.0 amps 3.0 amps maximum per Resistor 4.7KOhms 1 2 watt PN71252 Wiring Voltage Drop 2 VDC a list of compatible devices refer to the Gamewell FCI Device Document P N 52195 Relays Programmable TB8 Form C Relays for TB8 specifications are listed below Relay 1 factory default programmed as Alarm Relay Relay 2 factory default programmed as fail safe Trouble Relay Relay 3 factory default programmed as Supervisory Relay Relay Contact Ratings 2 amps 30 VDC resistive 2 amps 30 VAC resistive Trouble Input J6 Auxiliary Trouble Input is an open collector circuit which can be to monitor external devices for trouble conditions It can be to the trouble bus of a peripheral such as a power supply is compatible with open collector circuits Application Resettable Power TB9 Special Application Resettable Power TB9 specifications are below Voltage Nominal 24 VDC Available Current 500 mA appropriate for powering 4 smoke detectors see note 1 A Power limited Circuitry a list of compatible devices refer to the Gamewell FCI Device Document P N 52195 1 Total current for resettable power non resettable power and Circuits must not exceed 7.0 amps Application Resettable or Non resettable Power TB9 Special Application Resettable or Non resettable Power TB9 are listed below Voltage Nominal 24 VDC Available Current 500 mA see Note 1 A Power limited circuitry selectable by JP31 for resettable or non resettable power a list of compatible devices refer to the Gamewell FCI Device Document P N 52195 Information Six zone 24 volt Pre action Deluge Control Panel includes