Gamewell-FCI Flex GF506R Agent Release Control Panel

File Preview
File Preview
Click below to download for free

File Data

Name gamewell-fci-flex-gf506r-agent-release-control-panel-8430597162.pdf
Type PDF
Size 650.19 KB
Downloads

Text Preview

Conventional Control Panels GF506R Releasing Flex GF506R is a six zone FACP used for single and dual hazard agent releasing The Flex GF506R provides reliable fire detection It also offers signaling protection for commercial industrial and institutional buildings that require releasing The Flex GF506R is compatible with System Sensor i3 i3 detectors are conventional smoke detectors that transmit a maintenance signal to the FACP that indicates the need for cleaning It also transmits a signal when the ambient temperature falls below the detector of approximately 45 7.22 In addition the Flex GF506R control panel is with the following conventional input devices two wire and four wire smoke detectors pull stations waterflow devices and tamper switches other normally open contact devices a complete listing of compatible devices refer to the Gamewell FCI Device Document P N 52195 are four outputs that are programmable as NACs Notification Appliance or releasing circuits Three programmable Form C relays factory for Alarm Trouble and Supervisory and the 24 VDC special application and non resettable power outputs are included on the main circuit board Flex GF506R supervises all wiring AC voltage battery charger and battery level activation of a compatible smoke detector or any normally open fire alarm device will do the following Turn on audible and visual signaling devices Display alarm information on the panel LCD Activate the FACP alarm relay Operate an optional module used to notify a remote station or initiate an auxiliary control function Light an indicator Sound the piezo sounder at the FACP Flex GF506R BENEFITS Listed under UL 864 9th IBC Seismic Certified Designed for Agent NFPA 12 12A 2001 and 2010 Disable Enable control input zone and zone Extensive transient Dual hazard operation Adjustable pre discharge waterflow delay Cross zone double capability Six programmable B Class B IDCs Device with optional A wiring System Sensor i3 series compatible Four programmable Y Class B output special power with Z Class A option Strobe System Sensor Cooper Wheelock Gentex Faraday Amseco Three programmable relays 7.0 amps total 24 VDC current Resettable and non History Log with 256 Silenceable or Non output Built in Programmer ANN BUS for to optional to 8 total of any of following GFANN 80 Remote Annunciator GFANN S PG Printer GFANN RLY Relay GFANN LED Module 80 character LCD backlit Real time clock w daylight time control storage Piezo sounder for trouble and 24 volt DC operation Low AC voltage sense Outputs for the Releasing circuits or NACs programmable the following Silence Inhibit Auto Silence Strobe Selective Silence mute Temporal or Steady Release Stage Sounder Extensive transient Automatic battery with charger Optional Dress Panel red Optional Trim Ring TR red for semi flush the cabinet Optional CAC 5X Class Converter Module for and IDCs Optional 4XTMF Box Module Optional Digital Alarm 411 411UDAC and Software programming software offers the following features Custom English labels per point may be manually entered or from an internal library file Programmable Abort operation Three programmable Form C relay outputs Pre programmed and custom application templates Continuous fire protection during online programming at the front Program Check automatically catches common errors not linked to zone or input point Interface user interface features are listed below Integral 80 character LCD display with backlighting Real time clock calendar with automatic daylight savings Alarm Silenced yellow Discharged red Pre discharge red indicator Control Buttons Acknowledge Alarm Silence ANN Bus for connection to remote annunciators Audible or silent walk test capabilities Piezo sounder for alarm trouble and supervisory and Indicators panel provides the following LED Indicators Fire Alarm red Supervisory yellow Trouble yellow AC Power green Abort yellow indicator System Reset lamp test Drill Power TB1 AC Power TB1 for each panel is listed below GF506R 120 VAC 50 60 Hz 2.3 amps Wire size minimum 14 AWG 2.0 mm2 with 600V insulation Supervised non power limited sealed lead acid only J12 Battery for sealed lead acid only J12 specifications are listed Charging Circuit Normal Flat Charge 27.6 VDC 1.4 Supervised non power limited Charger Capacity 26 Amp Hour battery two 18 Amp batteries can be housed in the FACP cabinet Larger batteries separate battery box such as the BB 26 or BB 55 Battery Size 7 Amp Hour Device Circuits TB4 and TB6 Initiating Device Circuits for TB4 and TB6 specifications are listed Alarm Zones 1 5 on TB4 Alarm Zone 6 on TB6 Supervised and Class 2 Power Limited circuitry Style B Class B wiring with Style D Class A option Operating Voltage Nominal 20 VDC Current 15 mA minimum Circuit Current 40 mA max Loop Resistance 100 Ohms Resistor 4.7KOhms 1 2 watt PN 71252 Current 4 mA a list of compatible devices refer to the Gamewell FCI Device Document P N 52195 Appliance and Releasing Circuit s TB5 and TB7 notification appliance and releasing circuits for TB5 and TB7 are listed below Four Output Circuits Style Y Class B or Style Z Class A with optional converter module Notification Appliance and Releasing Circuit s Strobe Special Application power Supervised and Class 2 Power Limited circuitry Operating Voltage Nominal 24 VDC Signaling Current 7.0 amps 3.0 amps max per NAC 3 is a trademark of Honeywell International Inc 2 of 3 9021 60467 E 10 04 2018 Resistor 4.7KOhms 1 2 watt PN71252 Wiring Voltage Drop 2 VDC a list of compatible devices refer to the Gamewell FCI Device Document P N 52195 Relays Programmable TB8 Form C Relays for TB8 specifications are listed below Relay 1 factory default programmed as Alarm Relay Relay 2 factory default programmed as fail safe Trouble Relay Relay 3 factory default programmed as Supervisory Relay Contact Ratings 2 amps 30 VDC resistive 2 amps 30 VAC resistive Trouble Input J6 Auxiliary Trouble Input is an open collector circuit which can be to monitor external devices for trouble conditions It can be to the trouble bus of a peripheral such as a power supply is compatible with open collector circuits Application Resettable Power TB9 Special Application Resettable Power TB9 specifications are below Operating Voltage Nominal 24 VDC Maximum Available Current 500 mA appropriate for powering 4 smoke detectors see note 1 Class 2 Power Limited circuitry a list of compatible devices refer to the Gamewell FCI Device Document P N 52195 1 Total current for resettable power non resettable power and Circuits must not exceed 7.0 amps Application Resettable or Non resettable Power TB9 Special Application Resettable or Non resettable Power TB9 are listed below

Related Files