Gamewell-FCI Flex GWF410 Ten Zone FACP
File Preview
Click below to download for free
Click below to download for free
File Data
Name | gamewell-fci-flex-gwf410-ten-zone-facp-9620715834.pdf |
---|---|
Type | |
Size | 630.03 KB |
Downloads |
Text Preview
Conventional Control Panels Series Flex 410 Zone Expandable Conventional Fire Alarm Control Panel Flex 410 is a ten zone fire alarm control panel FACP that offers the flexibility to expanded to twenty or thirty zones using the optional CZM 400 zone expander The Flex 410 is an ideal fire panel that can be used for a wide range of sized installations such as hotels schools correctional institutions health facilities small office buildings and manufacturing plants can program the Initiating Device Circuits IDCs for the Flex 410 as either ten B Style B or five Class A Style D circuits This panel is expandable to either Class B ten Class A or thirty Class B fifteen Class A IDC circuits The panel compatible with a variety of conventional two wire smoke detectors four wire detectors and notification appliances This includes System Sensor i3 Series detectors and offers advanced features like drift maintenance alert and freeze warning See Appendix A of the Flex Installation Operations Manual P N 151321 for a list of compatible devices include four Class B Style Y or two Class A Style Z supervised Notification Circuits NACs to annunciate alarm conditions NAC circuits support circuit synchronization regulated Three programmable auxiliary relay outputs be programmed to activate for all zones or individual zones pre alarm system or circuit troubles such as the following fire alarm auxiliary alarm loss of AC phone line trouble low battery fire drills communication failure NAC trouble Flex 410 includes a built in Digital Alarm Communicator DACT to report the to a central station A user friendly two line LCD display and keypad makes programming and control simple The Flex 410 cabinet can be installed as or surface mounted and a Plexiglas window dead front door kit is available jurisdictions require it The fully regulated efficient 6 amp power supply with ensures adequate power is available at all times Flex 410 fire alarm control panel is listed to UL Standard 864 9th Edition alarm by zone Flex 410 BENEFITS Offers 10 Class B Style or 5 Class A Style D Device IDCs up to 30 B or 15 Class A with optional zone Supervised zone and I O can be remotely in accessory with 2 and detectors Built in digital alarm DACT dual phone line Includes four Class B Y or two Class A Z supervised appliance NACs Uses built in walk test All zones are Provides the following Displays built in 2 line Programmable NAC patterns ADA compliant strobe synchronization ANSI audible signals as required by NFPA 72 Single Stroke BI Constant output California code March code Municipal box service polarity reversal LCD with easy to English language Includes three general relays Programmable from remote or using connect port for downloading SmartProgram software to minimize following false alarms smoke verification pre alarm delay cross zoning enhanced verification Programmable date for Daylight Time and source setting for 50 Hz 60 or internal clock Each GWCZM 400 zone expander provides the control with ten additional Class B Style B zones or five Class A Style zones The GWCZM 400 connects to the control panel via the SBUS and is supervised and Class A power limited Up to two expanders can be used per panel It mounts in an FACP or into a accessory cabinet This status display module provides outputs and functions for remote annunciation of alarm trouble and for each zone The system can supervise up to eight status display modules It mounts in an FACP or into a accessory cabinet The GWRAN 400 remote annunciator can perform all control operations It also provides trouble and alarm and can be used for programming The FACP can support to four GWRAN 400 remote annunciators It mounts in a dual electrical box This accessory cabinet is used for mounting GWCZM zone expander and or GWIOM 410 status display module This door option combines a dead front panel with a bicarbonate window to limit access to the control panel It is for jurisdictions where single button operation is required Information Flex 410 FACP 10 zones expandable to 20 and 30 zones VAC Flex 410 Installation Operation Manual Zone expander module adds 10 Class B or 5 Class A Input output relay supervisory status module Remote annunciator for Flex 410 Accessory cabinet for mounting GWCZM 400 or Dead front door with Plexiglas window SmartProgram 400 for remote programming of the Flex 410 a PC available only to authorized distributors at ESD extranet 2 of 3 9021 60294 C 10 26 2018 Series Flex 410 Technical Specifications Flex Series 410 panel is designed to comply with following standard Standard S521 LISTINGS AND APPROVALS listings and approvals apply to the modules in this document In some cases certain or applications may not be listed by certain agencies or listing may be in process factory for latest listing status S521 7165 1703 0162 9001 Certification 3 is a trademark of International Inc is a registered trademark Underwriter Laboratories document is not intended be used for installation We try to keep our information up to and accurate We cannot all specific applications anticipate all requirements specifications are subject to without notice of origin U S A Power 120 VAC 60Hz 3 A charging circuit 27.4 VDC 0.75A charger capacity 33 Ah two 18Ah batteries fit FACP Power 24 VDC operating voltage DC Load 6 A Device Circuits IDC 2 wire smoke 17.5 VDC current draw panel 460 mA circuit current 95 mA maximum current draw panel 140 mA impedance 50 ohms 27.4 VDC 1 A Circuits NAC 27.4 VDC 3 A max 6 A total line impedance 1.5 ohm 2.5 A 24 VDC inductive 5 A 24 resistive non power limited Range 32 F to 120 F 0 C to 49 C 410 Cabinet 26 3 8 H x 17 3 16 W x 4 D x 44 x 10 cm 10 3 8 x 10 3 16 x 3 26 x 26 x 8 cm and Humidity Ranges system meets NFPA requirements for operation at 49 120 and at a relative humidity 93 RH noncondensing at 32 2 90 3 the useful life of the system standby and the electronic components may be affected by extreme temperature ranges and Therefore it is recommended that this and its peripherals be installed in an with a normal room temperature of 15 80 Gamewell FCI Clintonville Road CT 06472 1610 C 10 18 Honeywell International Inc