Gamewell-FCI IdentiFlex 600 Series, IdentiFlex 602 SmartScan (IF602SS)
File Preview
Click below to download for free
Click below to download for free
File Data
Name | gamewell-fci-identiflex-600-series-identiflex-602-smartscan-if602ss-6704231598.pdf |
---|---|
Type | |
Size | 919.64 KB |
Downloads |
Text Preview
600 Series Series Series Series 602 602 602 602 with Velociti with Velociti with Velociti with Velociti Addressable Control Panel Listed per ANSI UL 864 9th Edition One or two Signaling Line Circuits SLC up to 396 Velociti protocol 99 detectors 99 devices per Loop SmartStart self programming logic Downloadable or front panel programmable Password protected Approved for Supervisory Service Fully digital SLC protocol SmartLink peer to peer networkable 1000 event history log Automatic drift compensation Coded signaling capability Adjustable sensor sensitivity and temperature settings Style 6 7 Class A or Style 4 Class B SLC Four Style Y Class B or two Style Z Class A appliance circuits NACs Semi flush mounting between 16 studs 160 character display Optional GW UDACT Compatible Built in strobe and horn synchronization ISO 9000 2000 Company IdentiFlex 602 IF602SS with Velociti is ideally for small to medium sized installations at commer institutional and industrial life safety projects IF602SS has all the features of today most advanced safety systems The integration of analog and address hardwired circuits allows system engineers to custom panels and maximize efficiency for any application IF602SS can monitor and control up to 396 intelligent addressable input output points The interactive display uses LED prompting for ease of pro and user operation The alphanumeric display keypad simplify the field programming or the down programming from a Windows application IF602 housing was designed to be both aesthetically and functionally sound The cabinet is designed to between studs for semi flush mounting This compact and key activated dead front construction secure routine maintenance of the system Access system function keys is limited by a key switch Multiple of password protection prohibit unauthorized use circuit boards are mounted on a removable chassis are designed with pluggable terminal strips for ease of and service Display IF602SS operator display controls all user access the system The display provides all of the necessary and annunciation points to maintain and monitor the Alarm supervisory and trouble conditions are all on the operator display by dedicated LEDs and internal sounder The Acknowledge Reset and Signal keys are located directly below the 4 x 40 charac backlit alphanumeric display All system functions and logic can be programmed from the front panel the field The IF602SS display has four user program function keys and SmartStart are trademarks and Velociti Series is a registered trademark Honeywell International Inc is a registered trademark of Underwriters Laboratories Inc Windows is a registered trademark of Microsoft Corporation are for information only are not intended for installation purposes and are subject to change without notice No responsibility is assumed by Gamewell FCI for their use Honeywell International Inc All rights reserved Rev B page 1 of 3 Clintonville Road Northford CT 06472 1610 USA Tel 203 484 7161 Fax 203 484 7118 Display and Control annunciator drivers are available in 16 point incre and are an ideal interface to graphic annunciators serial annunciators display system activity and control can be used for Acknowledge Reset Signal Drill etc to customize the remote status control alphanumeric display can also be used for remote sta and control The alphanumeric display is designed to over the serial communications network IF602SS can communicate locally or remotely with a to document system activity the RAN SAN data sheet CS 2025 and CS 2027 for annunciator details Analog Addressable Control Panel for new or retrofit small to mid sized projects that state of the art life safety systems The embedded offers users unrivaled reliability without sacrificing or value compatible analog sensors and addressable input and interface devices and its remote status and control the IF602SS provides system engineers with the tools necessary to design effective system solutions any application Specifications control panel furnished and installed shall be capable supporting 396 addressable devices and two analog The panel shall use a fully digital Signaling Line Cir SLC protocol The panel shall contain four on board Appliance Circuits NACs that support the mul synchronization protocols The panel shall use a 160 Liquid Crystal Display LCD and a 1,000 event log The panel shall be a Gamewell FCI IF602SS Velociti Addressable Signaling Line Circuits IF602SS analog interface module provides Signaling Circuits SLC loop circuits that can monitor and con up to 198 analog addressable devices on each power loop for a total of 396 analog points in a dual loop Loop wiring is polarity sensitive SLC loop has a dedicated microprocessor that simul communicates with connected field devices and main CPU IF602SS uses Velociti fully digital communications to improve the speed and accuracy of event The communications protocol provides for alarm per detector detector adjustability and compen adjustable analog heat detector range circuit isola and priority interrupts Priority interrupts allow contact devices such as manual fire alarm stations to interrupt polling cycle and transmit their addresses at any time a polling sequence fully digital protocol allows the IF602SS to operate on types of field wiring greatly expanding its use in retro applications Consult the Supplemental SLC Manual or Technical Support specific wiring Power Supply IF602SS power supply is a fully regulated 8 amp sup that furnishes system operating and signaling power It equipped with a battery charger which maintains the sec power source The power supply is monitored by main CPU ensuring that adequate power levels are The power supply design allows for high effi while providing precise power output The battery maintains batteries up to 26 AH The supply pow four on board Notification Appliance Circuits NACs Class A with the multiple built in synchronization pro for System Sensor Cooper Wheelock and others I Output O Devices control output devices are the interface analog circuits and building functions The outputs controlled with Control By Event CBE software within IF602SS and can be programmed to respond to any The control devices can be used as supervised signaling circuits IF602SS with Gamewell FCI complete line of 600 devices provides a foundation for system design IF602SS RS 232 output expands system monitoring control capabilities Rev B page 2 of 3 Clintonville Road Northford CT 06472 1610 USA Tel 203 484 7161 Fax 203 484 7118 Control Current Current Power Output A A Relays plus signaling circuit plus 0.002A for master box plus 0.022A for reverse polarity VAC 4.0A or 240 VAC 2.0A A maximum 30 VDC or 0.5A 250 Appliance Circuits Class B two Class A maximum 24 VDC per circuit 7.5A total for all circuits SLC Current Current Dimensions Cabinet 20.0 H x 14.0 W x 4.5 D H x 35.6 W x 11.4 D cm Storage Dimensions Cabinet 6.0 H x 9.0 W x 4.5 D H x 22.86 x 11.43 D cm Humidity 93 non condensing 120 0 49 Information IF602SS Analog Addressable System V