Gamewell-FCI IdentiFlex 610 with SmartScan Control Panel

File Preview
File Preview
Click below to download for free

File Data

Name gamewell-fci-identiflex-610-with-smartscan-control-panel-9081342756.pdf
Type PDF
Size 646.32 KB
Downloads

Text Preview

600 Series 610 SmartScan Addressable Control Panel Two or four Signaling Line Circuits SLC up to 792 SmartScan protocol up to 99 detectors and 99 per loop SmartStart self programming logic Programmable by PC or front panel Password protected Approved for Supervisory Service Fully digital SLC protocol SmartLink networkable 1000 event history log Automatic drift compensation Coded signaling capability Adjustable sensor sensitivity and temperature settings Day night sensitivity setting Supervisory service Style 6 Class A or Style 4 Class B SLC Two Style Y Class B or two Style Z Class A notifica appliance circuits NACs Semi flush mounting between 16 studs 160 character display Optional integrated voice evacuation Optional UDACT Agent Releasing service ISO 9000 2000 Company IdentiFlex 610 IF610SS with SmartScan is suited medium sized installations of commercial institutional industrial life safety applications IF610SS offers all the features of today most life safety systems The integration of analog addressable hardwired circuits allows system engi to customize panels and maximize efficiency for a application The IF610SS can be networked with up 256 other 600 Series panels using Gamewell FCI peer to peer network IF610SS can monitor and control up to 792 intelligent addressable input output points Analog circuits are up by Gamewell FCI Default Alarm Mode for security The 1,000 point history log furnishes a record of system activities The interactive opera display uses LED prompting for ease of programming user operation The alphanumeric display and keypad field programming or program from a PC using SmartProgram II programmer IF610SS cabinet will fit between 16 studs for semi mounting The compact design and key activated construction enables secure routine mainte of the system Access to system function keys is lim by a key switch Multiple levels of password protection unauthorized use The circuit boards are mounted a removable chassis and are designed with pluggable strips for ease of installation and service Display IF610SS operator display provides all user access the system The display has all the necessary keys and points to maintain and monitor the system supervisory and trouble conditions are indicated on operator display by dedicated LEDs and an internal The Acknowledge Reset and Signal Silence are located directly below the 4 line by 40 character alphanumeric display All system functions and logic can be programmed directly from the front Series and SmartStart are trademarks of Honeywell International Inc Windows is a registered trademark of Microsoft Corporation are for information only are not intended for installation purposes and are subject to change without notice No responsibility is assumed by Gamewell FCI for their use Clintonville Road Northford CT 06472 1610 USA Tel 203 484 7161 cid 129 Fax 203 484 7118 Honeywell International Inc All rights reserved Rev A page 1 of 3 alphanumeric display can also be used for remote sta and control The alphanumeric display will communi over the serial communications network IF610SS can communicate locally or remotely with a to document system activity the RAN SAN data sheets CS 2025 and CS 2027 for annunciator details IF610SS Analog Addressable Control Panel is ideal new or retrofit small to mid sized projects that require life safety systems The embedded CPU users unrivaled reliability compatible analog sensors and addressable input and interface devices and its remote status and control the IF610SS provides system engineers with the tools necessary to design effective system solutions Addressable Signaling Line Circuits IF610SS analog interface module provides two or four Line Circuits SLC loop circuits that can monitor control up to 198 analog addressable devices on each for a total of 792 analog points in a four loop system SLC loop has a dedicated microprocessor that simul communicates with connected field devices and main CPU IF610SS uses the SmartScan fully digital communi protocol for superior speed and accuracy of event This protocol provides alarm verification per detector adjustability and compensation adjust analog heat detector range circuit isolation and prior interrupts Priority interrupts allow contact type devices as manual fire alarm stations to interrupt the polling and transmit their addresses at any time this fully digital protocol the IF610SS will operate on types of field wiring greatly expanding its use in retro applications Consult the supplemental SLC manual or Technical Support specific wiring Power Supply IF610SS power supply is a fully regulated 6 Amp sup that furnishes system operating and signaling power It equipped with a battery charger which maintains the sec power source The power supply is monitored by main CPU ensuring that adequate power is available power supply design allows for high efficiency while precise power output The battery charger main batteries up to 26 AH The supply powers two on Notification Appliance Circuits NACs Class A or B I Output O Devices control output devices are the interface analog circuits and building functions The outputs controlled by Control By Event CBE software within IF610SS and can be programmed to respond to any The control devices can also be used as supervised signaling circuits IF610SS RS 232 output expands system monitoring control capabilities Display and Control designers and engineers can add serial annuncia to display system activity and control Serial annuncia drivers are available in 16 point increments and are an interface to graphic annunciators Switches can be for Acknowledge Reset Signal Silence Drill etc to the remote status control network Rev A page 2 of 3 Clintonville Road Northford CT 06472 1610 USA cid 129 Tel 203 484 7161 cid 129 Fax 203 484 7118 Control Current Current Power Output A A Relays plus signaling circuit plus 0.002A for master box plus 0.022A for reverse polarity VAC 2.0A combined 30 VDC or 0.5A 250 VAC Circuits 24 VDC 2.0A per circuit SLC Current Current Dimensions Cabinet 20.0 H x 14.0 W x 4.5 D Cabinet H x 35.6 W x 11.4 D cm H x 22.0 W x 5.5 D H x 55.9 W x 13.97 D cm Storage Dimensions Cabinet 6.0 H x 9.0 W x 4.5 D Cabinet H x 22.86 W x 11.43 D cm H x 22.0 W x 5.5 D H x 55.88 W x 13.97 D cm Humidity 93 non condensing 120 0 49 Information Number Description analog addressable system of the following common control main CPU front display with the following LCD alphanumeric display Bus driver module Common system relays Ribbon cables 6 Amp main power supply Two 2 SmartScan analog circuit 396 analog addressable Standard cabinet assembly Cabinet H x 14.0 W x 4.5 D H x 35.6 W x 11.4 D cm Information Continued Number Description 396 point two SLC IF610SS in extra large allowing space for battery Refer to IF610SS 396R model above H x 22.0 W x 5.5 D H x 55.88 W x 13.97 D cm two 2 analog circuit cards a total of 396 analog addressable analog addressable system with

Related Files