Gamewell-FCI IdentiFlex 610VE Fire Alarm Control Panel

File Preview
File Preview
Click below to download for free

File Data

Name gamewell-fci-identiflex-610ve-fire-alarm-control-panel-6148520793.pdf
Type PDF
Size 754.39 KB
Downloads

Text Preview

Sheet B250 Fire Alarm Panel and Voice System ALARM CONTROL PANEL 126 to 504 Addressable Points Fully Field programmable with ad SmartStart auto program Upload Download PC compatible Built in 160 Character 4 x 40 backlit Display Style 4 6 and 7 Input SLC Circuits Automatic Drift Compensation Adjustable Sensor Sensitivity Setting Complies with NFPA 72 Sensitivity Requirements Style Y and Z NAC Circuits Power Limited I O Circuits Programmable Coded Signaling Adjustable Signal Silence Inhibit 1,000 Event History Logging Emergency Default Alarm Mode Positive Alarm Sequence Serial Annunciator Printer and Alpha support and Cross Zoning Deluge Pre Action and Releasing SmartNet Network Compatible EVACUATION SYSTEM Fully Supervised Amplifiers 25 50 100 Watt Systems Use 25 or 70 Volt Speakers Style Y or Z Outputs Manual Override by Circuit All Call Operation Digitally Recorded Automatic Voice Messages 4 Minute Message Capacity Multiple EVAC Tones Paging Microphone with Override of and Tones Circuit Modules Integral Power Supply Charger Dead Front Construction IdentiFlex Intelligent Fire Control Panel and Emergency Evacuation System IF610VE is key addition to Gamewell fourth of intelligent addressable products The latest in mi technology and unparal years of experience are com in the IF610VE to give building a fire alarm and emergency system that will provide of service as only Gamewell can offer Alarm Control Panel IF610VE can monitor and or con up to 504 addressable points in intelligent addressable sensors building control devices including CZI RCE and SCE modules For security Gamewell s Default Mode provides backup of intelli circuits and the 1,000 point history furnishes a complete record of all activities The interactive Op Display uses LED prompting to both user operation and program The 160 character alphanu display and keypad or a com link simplify field programming an embedded microprocessor IF610VE offers the features neces in today s most advanced life systems Integration of intelli and hardwire circuits through Zone Interface CZI and Identification Device PIDs mod allows a systems engineer to the control for maximum efficiency Evacuation System emergency voice capability of the Gamewell provide pre natural voice messages to an orderly evacuation of the areas Voice evacuation are frequently required by Authority Having Jurisdiction for areas of assembly such as gymnasiums places of and large meeting rooms IF610VE System provides an means to meet this need used are available in several to deliver performance in an pleasing dead design Each amplifier has its Power Supply and Battery An optional digital message is available with any of the systems Selection of tone and voice message repeat are configured in the field fully supervised emergency paging with a is an integral component of the of the microphone from the will cause a condition will be reported to the associated unit To prevent a out of emergency voice evacuation mes capability each VE includes a 3 message restart which occurs after a three minute de of the microphone key This feature helps to ensure reliability functionality of the system Emergency Voice System may also be with multiple speaker circuit Circuit splitter modules the amplifier power to be divided multiple zones for efficient use controlled zone signaling modules are equipped with select switches that allow for selection of voice evacuation for emergency paging An LED is for annunciation of each zone IF610VE enclosure can house up to Watts of amplification paging digital voice messaging one or two circuit splitter modules up to 8 Class B Style Y or 4 Class Style Z circuits All modules are behind a glass door for visibility status LED Display IF610VE operator display is the of all user access to the system display supplies all necessary keys annunciation points to maintain and the system Alarm Supervisory Trouble conditions are all indicated the operator display by dedicated and the internal sounder The Reset and Signal Silence are centered at the bottom of the directly below the 4 x 40 adjust angle backlit alphanumeric display System Acknowledge key is used acknowledge all off normal conditions will silence the internal sounder and flashing LED will illuminate steady conditions are returned to normal reset key is used to return the panel to the normal idle mode an alarm condition has been Trouble conditions that have cleared will automatically return control panel to the idle mode conditions have been will resound the internal if the condition is not corrected a 24 hour time period Signal Silence key can be used to notification appliances This can be modified by user pro to only operate after a speci time period Silence Inhibit to in that the signals are not turned off the cause has been investigated annunciation is also provided for Power Pre Alarm Alarm Trouble Supervisory Alarm conditions Common Control IF610VE Common Control is the of the system The common con section houses the main CPU and system memory as well as providing and remote communications and The common control con the common system relays two Appliance Circuits NACs tie and RS 232 port All interactions the common control are through the display panel relay circuits are provided for con of auxiliary functions The relays are by the main CPU and are field two 24 VDC NACs may be config for steady output or be coded as be required All circuits are power per NEC 760 and UL 864 for output Supply system power supply furnishes sys operating and signaling power The supply design provides for high with precise power output main CPU monitors the supply to power levels are maintained 6 Amp supply is equipped with a charger capable of maintaining a acid battery backup of up to 25 AH charger automatic high rate circuit monitored by the main CPU Interface Module Intelligent Interface module pro a minimum of a one loop circuit can monitor and control up to 126 Addressable devices The system is available in a one module 126 points a two loop 252 points and a four loop 504 points configuration Field is possible from one to two or loops intelligent interface module has a microprocessor that simulta communicates with the con field devices and the main CPU allows the IF610VE to maintain speed throughout the Intelligent circuits may be wired Style 4 6 or 7 performance intelligent interface module uses an protocol to improve the speed accuracy of event rep

Related Files