Gamewell-FCI IdentiFlex 650 with SmartScan Control Panel
File Preview
Click below to download for free
Click below to download for free
File Data
Name | gamewell-fci-identiflex-650-with-smartscan-control-panel-7316825409.pdf |
---|---|
Type | |
Size | 658.38 KB |
Downloads |
Text Preview
600 Series 650 SmartScan Addressable Control Panel Analog addressable and conventional input circuits SmartScan protocol 99 detectors and 99 devices per SmartStart self programming logic Fully modular 160 character four line display One to 16 Signal Line Circuits SLC for up to 3168 points Automatic default response for increased survivability 1000 event history log Digital SLC protocol PC or front panel programming Password protected Serial annunciator remote display and remote printer One man selectable input walk test Automatic drift compensation Coded signaling Day night mode settings Approved for Supervisory Service Optional UDACT Adjustable sensor sensitivity and temperature settings SmartLink network compatible ISO 9000 2000 Company IdentiFlex 650 IF654 658 with SmartScan is a full Fire Alarm Control Panel FACP to monitor and both analog intelligent addressable devices and hard wired zones providing maximum appli flexibility It is easily adapted to a new or retrofit and has all the power and features to handle of any size and complexity providing up to 3168 addressable points plus 96 conventional circuits the addition of a SmartLink network the IdentiFlex system can include multiple IF650s or other 600 fire alarm panels The interactive operator display LED prompting for easy user operation and program The alphanumeric display and keypad simplify field Gamewell FCI SmartProgram II can be to program the IF650 with a PC IdentiFlex 650 has all the features of today most life safety systems Integration of analog and circuits allows the system engineer to custom the control panel based on the application The CPU senses system configuration to ensure that are correctly positioned to speed installation and 650 software allows the system to be custom to specific applications such as cross zoning and verification construction is designed to allow routine main of the system without disturbing the I O modules levels of password protection prevent unautho use The cabinet is designed with terminal strips for of installation and service Display IdentiFlex 650 operator display has all the necessary and annunciation points to maintain and monitor the Alarm Supervisory and Trouble conditions are all on the operator display by dedicated LEDs and internal sounder The Acknowledge Reset and Signal keys are easily found on the display and SmartLink are trademarks of Honeywell International Inc are for information only are not intended for installation purposes and are subject to change without notice No responsibility is assumed by Gamewell FCI for their use Clintonville Road Northford CT 06472 1610 USA Tel 203 484 7161 cid 129 Fax 203 484 7118 Honeywell International Inc All rights reserved Rev A page 1 of 4 Display Continued Reset key returns the control panel to idle mode after alarm condition has been cleared Trouble conditions have been cleared will automatically return the control to idle mode when the problem has been corrected conditions that have been acknowledged will the internal sounder if the condition is not cor within a programmed time period Signal Silence key deactivates notification appliances function can be modified by user programming to only after a specified time period are three additional programmable switches avail to control application specific operations Keys for and bypass functions along with LEDs for and trouble conditions are provided for the City and two signal circuits which are part of the Control section Panel System Components IF650 COMMON CONTROL SECTION comprises the of the system The common control section houses main CPU and all system memory as well as providing and remote communications and supervision The control contains the common system relays two circuits city tie and optional EIA 232 port All inter with the common control section is through the oper display panel Four relay circuits control auxiliary The relays rated at 10 Amps are controlled by main CPU Two 24 VDC notification appliance circuits are provided The NACs can provide a steady or output All circuits are power limited per NEC 760 UL Standard 864 IF650 SmartScan ANALOG INTERFACE MODULE and SSM 4 occupies one bay and has from to four circuits that can monitor and control up to 198 devices each for a total of 792 points bay Gamewell FCI IF650 systems can be configured up to 3168 points The analog interface module has a microprocessor which simultaneously communi with the connected field devices and the main CPU feature allows the IF650 to maintain maximum com speed throughout the system Analog addres circuits can be wired as non polarized in Style 4 6 or The communications protocol provides for alarm verifica per detector detector adjustability and compensation analog heat detector range circuit isolation and interrupts Priority interrupts allow contact type such as manual fire alarm stations to interrupt the cycle and transmit their addresses at any time dur a polling sequence The SmartScan digital protocol the IF650 to operate on most types of field wiring expanding its use in retrofit applications consult Technical Support specific wiring CONVENTIONAL INPUT MODULE CIM 8 occupies bay and provides eight hard wired input circuits for conventional detectors and contact type The CIM 8 monitors and reports each circuit status to the CPU as it distinguishes between and contact devices and determines if two or detectors are in alarm Each input module uses one in the MPU bus and is supplied with its own display The display module provides LED annunciation of and trouble conditions and has a switch per circuit programming and bypass functions The display has for user defined custom labels for each circuit normal alarm and supervisory functions the input can be programmed for Remote Acknowledge Signal Silence and Release Abort switches Cir can be wired for Style B D and E service and are of monitoring normally closed devices 600 Series UNIVERSAL SIGNAL MODULE USM 8 one bay and is a multifunctional eight circuit out module USM 8 modules communicate via the MPU and require one expansion slot each The USM can be as 24 VDC signaling circuits Modules are pro in two circuit increments making it possible to all four functions with a single module Signal cir provide steady or coded outputs All circuits are per NEC 760 and UL 864 Signal circuits can wired in either Style Y or Z Signal modules are supplied their own display that provides LED annunciation of and trouble conditions and has a switch per cir for programming and bypass functions The display space for user defined custom labels for each circuit 600 Series POWER SUPPLY MPS 8 furnishes sys operating and signaling power The supply is equipped a battery charger for maintaining the secondary power The power supply is monitored by the main CPU to that adequate power levels are maintained The supply design allows for high efficiency while provid precise power output The battery charger is capable of with lead acid batteries and maintaining up to 50 batteries Multiple auxiliary power supplies APS 8 be added to the system when additional power is 600 Series RELAY MODULE RM 8 supplies eight relays for control of auxiliary functions The relays controlled by the main CPU and are fully programma Each position on the MPU bus can accommodate a module The relays are rated at 10 Amps and each is with a feedback point for positive confirmation of Like all 600 Series expansion modules the relay reports activation 6