Gamewell-FCI ILI95-E3 Series Intelligent Loop Interface-Main Board

File Preview
File Preview
Click below to download for free

Text Preview

Analog and Networking Systems Series Interface Apollo Protocol Gamewell FCI Intelligent Loop Interface95 Main Board ILI95 MB E3 is the circuit interface for the following E3 Series Systems using the Apollo Protocol devices E3 Series Expandable Emergency Evacuation System E3 Series Combined Fire and Mass Notification System its state of the art 32 bit RISC processor this compact on a board a powerful addition to Gamewell FCI single pair conductor solutions This design provides the following features two signaling line circuits two notification appliance circuits local energy city box output auxiliary relay functions auxiliary power output features combined with a built in network and serial protocols allow this to support a host of new and existing products resulting in a building block to the fire alarm control panel design ILI95 MB E3 provides two signaling line circuits and terminals for the to up to 126 Apollo detectors and modules per SLC The RS 485 can support up to a total of six LCD E3 and sixteen ASM 16 and or sixteen remote LED driver modules ILI95 MB E3 is network ready and occupies 64 nodes operating at 625K baud In the Addressable Node Expander ANX board expands the network to 122 When this sub assembly is integrated with proven Broadband components result is a flexible yet powerful integrated audio solution When the sub assembly to remote locations the optional RPT E3 provides the ILI95 MB E3 with signal boosting and transient protection as well as provides connectivity both wire and fiber optic cables ILI95 MB E3 relay outputs include system alarm supervisory and system contacts The ILI95 MB E3 provides output for a local energy city master box or for a remote location which is non power limited All wiring is Class 2 power limited BENEFITS 4100 Event History RS 485 supporting 16 Supports six local Listed under UL 864 9th Listed under UL UL2572 for Notification Provides network ready 625K baud 115.2K baud RS 232 line circuits 2 Class A Style 6 7 or B Style 4 circuits 40 Character user text per device Capacity of 126 devices per loop 7 wiring requires use of XP95 LI Modules Only 2 notification circuits Style Z or B Style Y rated at amps per circuit switch and or ANU LED driver modules Alarm trouble and dry Form at 2 amp 30 resistive LCD E3 and five LED Intelligent Loop Interface95 Expansion Board provides the E3 Series fire alarm control with two additional signaling line circuits The is similar to the ILI95 MB E3 except a number the following inputs outputs are omitted Notification Appliance Circuits Auxiliary Power RS 485 Communication Bus Form C Relays ARCNET Repeater Port ILI95 S E3 occupies one node on the Broadband The ILI95 S E3 provides two signaling line and terminals for the connections to up to 126 modules the ILI95 MB E3 or ILI95 S E3 can be in the following E3 Series cabinets Cabinet B and D backbox Cabinet B B Slim E3 sub assembly plate Cabinet C E3 ILI C sub assembly plate Cabinet C E3 INCC C sub assembly plate Cabinet C E3 INX C sub assembly plate Cabinet D E3 INCC D sub assembly plate Cabinet D E3 INX D sub assembly plate instructions on the installation of the ILI95 MB E3 ILI95 S E3 refer to the following documents E3 Series Expandable Emergency Evacuation Part Number LS10080 051GF E ILI95 MB E3 Installation Instructions Part Number ILI95 S E3 Installation Instructions Part Number information on the ILI MB E3 and ILI S E3 refer to ILI E3 Series Data Sheet Number 9020 0605 information on the ANX refer to the ANX Data Part Number 9021 60497 Information Intelligent Loop Interface95 Main Intelligent Loop Interface95 Expansion Series Technical Specifications Current 0.050 amp Current 0.091 amp max Current 0.109 amp Current 0.11 amp and ILI95 S E3 Voltage 24 VDC FWR from the PM 9 Power Supply Temperature 32 to 120 F 0 to 49 C Humidity 0 to 93 non condensing 90 F 32 C 2 Power Limited 40 Ohms maximum line impedance f maximum line capacitance AND HUMIDITY RANGES system meets NFPA requirements for opera at 0 49 120 and at a relative 93 2 RH noncondensing at 32 90 3 However the useful life of the standby batteries and the electronic com may be adversely affected by extreme tem ranges and humidity Therefore it is that this system and its peripherals installed in an environment with a normal room of 15 27 80 ILI95 E3 Series are designed to comply with the standards Standards UL 864 9th Edition UL 2572 for Mass Notification LISTINGS AND APPROVALS listings and approvals apply to the modules in this document In some cases certain or applications may not be listed by certain agencies or listing may be in process Consult factory for the latest listing status Listed S1869 Approved 3025415 Approved Fire Dept of New York 6175 231 06 E 7165 1703 0125 9001 Certification a complete listing of all approvals and please visit Series and Gamewell FCI registered trademarks of International Inc is a registered trademark Underwriters Laboratories document is not intended be used for installation We try to keep our information up to and accurate We cannot all specific applications anticipate all requirements specifications are subject to without notice more information more about Gamewell FCI ILI95 E3 Series and other available by visiting www Gamewell FCI com Gamewell FCI Clintonville Road CT 06472 1610 L 09 17 Honeywell International Inc

Related Files