Voice Evacuation E3 LOC INCC CAB B Network Command Center Gamewell FCI INCC Intelligent Network Command Center serves as the point of between an operator and the system audio evacuation fire fighter and building control circuits It is a component of the following systems E3 Series Expandable Emergency Evacuation E3 Series Combined Fire and Mass Notification System E3 Series Broadband Audio Evacuation System INCC occupies a single node along the E3 Series Broadband network and is by a single pair of twisted unshielded wire fiber optic cable or any of the two Each E3 Series Broadband node can be spaced along the at a maximum distance of 3,000 feet 914.4 m or up to an 8dB loss using cable For Class A only the maximum distance between nodes is 4,500 ft isolation at each node permits Style 4 Style 6 and Style 7 network E3 Series Broadband Audio Evacuation System is a peer to peer self token ring network comprised of up to 64 individual nodes in addition Addressable Node Expander ANX board expands the network to 122 nodes The Series Broadband employs proven technology and extends it to accomplish voice evacuation 2 way fire fighter communications and building control It is unique in the industry because it requires only a single pair of wires a fiber optic cable connection between nodes to convey all fire alarm digital voice fighter communications paging and building control signals typical INCC and E3 LOC INCC CAB B sub assemblies consist of the an Intelligent Network Interface Voice Gateway INI VGC Module one or more Addressable Switch Modules ASM 16 one Network Graphic Touchscreen Annunciator NGA BENEFITS Distributed All communication Listed under UL 864 9th Listed under UL UL2572 for Notification INI VGC connects to a Page and Fire Handset Each INI VGC supports to 16 ASM 16 modules for a of 256 switches including 7 wiring allow components to normal with NO loss function during line fault Uses network data rate at 625K and control by sequences over unshielded of wires or fiber cable including Audio Evacuation Voice Paging Fire Fighter Intercom Elevator Control Door Closures Fan Control and Damper Shutdown Fire Alarm and Control Devices Horn Strove Circuit Activation Integrates with INX and INCC centers to a complete evacuation with up to 122 Redundant Command with and Fire Handset can easily configured by the additional Advance Boolean logic programming as AND OR NOT time delay and functions through Advanced digital signal DSP for efficient compression and complete E3 Series Audio Evacuation System can assembled from the following different One or more E3 Series fire alarm control panels One or more INCC Audio Evacuation Command One or more INX Transponders One ACU Autonomous Control Unit One LOC remote Local Operating Console modular approach greatly simplifies the design installation process and can be configured to the exact needs of the project 1 shows the three ASM 16s MIC and Handset in the INCC 1 INCC with MIC and Handset INCC Command Center INI VGC module also connections for an optional emergency Page Microphone as well as a Fire Fighter Handset The INI VGC is a fully digital generator using state of the art Digital Processing DSP technology to produce the most audible signal possible The INI VGC an output to a local speaker for message and testing It can be used with a wide of complex System Applications including or campus installations Addressable Switch Module ASM 16 has 16 switches that can be programmed to any function the application demands An ASM switch can be programmed as any of the following Speaker Circuit switch Fire Fighter Phone switch Auxiliary Control switch using a bank of three one switch can be used for each On Off function Switches with the following custom defined System Reset System Silence System Acknowledge Alarm Tone On All Call Phone Patch Lamp Test Manual Select ASM 16 switch also has 3 fully programmable LEDs in red yellow and green The LCD Graphic Annunciator is a powerful yet component of the Gamewell FCI Voice Evacuation System The bright 1 4 VGA display is supplemented with an easy to use touch screen interface that the following features Up to 512 user defined messages may be Messages may be up to 77 characters in length Display font and color may be selected for each INCC assembly is enclosed in one or more 19 wall mounted enclosures Its modular provides complete flexibility in system Each cabinet can contain the INI VGC and up six ASM 16 modules If more ASM 16 modules are they may be mounted in additional INCC As many as six ASM 16 modules can fit in INCC cabinet If a Microphone module is required would take the place of one ASM 16 position A Fire Handset would take the place of two ASM 16 An INI VGC can support as many as sixteen for a total of 256 completely programmable INCC operates on 24 VDC that can be sourced the non resettable auxiliary output of its power supply such as the PM 9 or PM 9G 2 shows the six ASM 16s installed in the INCC 3 illustrates the INCC and E3 LOC INCC CAB B module installation configuration 2 INCC with 6 ASM 16s BACKBOX INI VGC INNER DOOR WITH ASM 16 MICROPHONE DOOR ASSEMBLY 3 INCC and E3 LOC INCC CAB B Module Configuration E3 LOC INCC CAB B Technical Specifications VDC nominal amp supervisory and alarm Voltage Current Temperature 32 to 120 F 0 to 49 C Humidity to 93 non condensing with half duplex data flow up to 64 KBps up to 128 KBps to 200 microns multi mode for 62.5 125 microns connectors Voltage Current VDC nominal amp supervisory amp alarm plus 0.003 amp per LED 0.195 amp max Temperature 32 to 120 F 0 to 49 C Humidity to 93 non condensing AND HUMIDITY RANGES system meets NFPA requirements for operation at 0 49 120 and at a relative humidity 93 2 non condensing at 32 2 90 3 the useful life of the system s standby batteries the electronic components may be adversely affected extreme temperature ranges and humidity Therefore it recommended that this system and its peripherals be in an environment with a normal room of 15 27 80 a complete listing of all approvals and please visit Series and Gamewell FCI registered trademarks of International Inc is a registered trademark Underwriters Laboratories document is not intended be used for installation We try to keep our information up to and accurate We cannot all specific applications anticipate all requirements specifications are subject to without notice Information Number Network Command Center center voice gateway switch module occupies 1 slot on the inner door Microphone module Fighter Telephone module door with 1 double slot used for the INCC Fire Fighter Handset and 4 single slots door with 6 single slots backbox black with black outer door W x 19 H x 4 D

Related Files