FCI INI 7100 Series Fire Alarm Network Specification No 9020 0543 1.1 June 3 2004 Control Instruments Inc Southwest Park Ma 02090 2001 Rights Reserved in the USA 1 GENERAL CONDITIONS Contractor shall furnish all equipment materials tools labor drawings and all associated necessary for a complete networked fire alarm system ready for operational turn over in with the requirements of the NFPA 72 and the authorities having jurisdiction The Contractor provide all devices and equipment required by the drawings and specifications The Contractor may delete any equipment or devices without submission and approval of a request for information detailing deletions The Contractor also may not change types of coverage without submission and approval of a for information detailing the reason for change ensure reliability and complete compatibility all Items of the Fire Alarm System including control power supplies as well as all initiating and indicating devices shall be listed by Fire Control FCI by Underwriters Laboratories inc UL and shall bear the label Partial listing shall be acceptable equipment and installation supervision furnished shall be listed as an approved distributor of Fire Instruments and shall produce proof of factory training within 14 calendar days of award of the DESCRIPTION successful bidder shall furnish and install a complete Networked Fire Alarm System with all wiring and connections as described on the drawings and this document The Networked System be wired in a supervised 2 wire fashion utilizing classes and styles as per NFPA 72 The System be a TRUE peer to peer network including Control panels 7100 Network interface cards INI Remote annunciators LCD 7100 Double action manual stations MS 7 Analog photoelectric smoke sensors ASD PL Analog addressable duct sensors AD P Analog addressable laser and multi criteria sensors ASD LS MCS Acclimate Series Addressable monitor modules AMM MMI Series Addressable control modules AOM MMO Series Synchronized Strobes and Combination horn strobes All wiring connections to devices boxes junction boxes and all other necessary material accessories mounting hardware A system shall conform to the latest editions of the following codes and standards Life Safety Code 101 Fire Alarm Codes NFPA 72 National Electrical Code 70 Americans with Disabilities Act ADA NFPA 12 Carbon Dioxide Extinguishing Systems NFPA 12A Halon 1301 Fire Extinguishing Systems NFPA 13 Installation of Sprinkler Systems NFPA 15 Water Spray Fixed Systems NFPA 16 Deluge Foam Water Sprinkler Systems NFPA 16A Installation of Closed Head Foam water Sprinkler Systems NFPA 17 Dry Chemical Extinguishing Systems NFPA 17A Wet Chemical Extinguishing Systems NFPA 72 National Fire Alarm Code Central Station Fire Alarm Systems 7100D Local Fire Alarm Systems Auxiliary Fire Alarm Systems Remote Station Fire Alarm Systems 7100D Proprietary Fire Alarm Systems 7100D NFPA 90A Installation of Air Conditioning and Ventilating Systems Life Safety Code NFPA 101 Safety to Life from Fire in Buildings and Structures NFPA 750 Water Mist Fire Protection Systems NFPA 2001 Clean Agent Fire Extinguishing Systems manufacturer shall guarantee all system equipment for a period of one 1 year from date of final acceptance A with the appropriate contractors for interfacing to building systems as required on the drawings but not limited to Elevator interface HVAC interface and Security system interface 10 copies of shop drawings and product data sheets in accordance with all sections of this The submittal shall include certification from Fire Control Instruments FCI verifying that the is an authorized agent who is qualified and trained by the manufacturer in the proper operation and service of the system Contractor shall include the following information in the equipment submittal A complete list of all supplied equipment including the quantities and model numbers used along with catalog data sheets on each component Complete drawings including the following Floor plans showing all control panels annunciators power supplies initiating devices Wiring diagrams showing points of connection and terminals used for connection to the system appliances and control devices and panels This shall include Any recommendations and precautions for installing the system devices Drawings of each control panel and power supply showing interconnections and terminations including contact ratings and interfaces to other systems Battery capacity calculations for each control panel and power supply Loading calculations showing total draw and capacity of each circuit AND MAINTENANCE MANUALS Before final acceptance testing submit a five 5 complete sets of operation and manuals along with five 5 sets of as built drawings The operation and maintenance shall include Building name and address The name and phone number of the contractor system manufacturer and system supplier The actual operation and maintenance manual supplied by the system manufacturer ALARM SYSTEM FUNCTIONALITY Provide a complete electrically supervised networked analog addressable fire alarm and control with analog initiating devices The system shall be a multiprocessor based control panels model FCI 7100 communicating over a token ring network with a capacity of up to 64 nodes Each node shall incorporate two 2 Signaling Line Circuits SLC with the capacity to support up to analog addressable detectors and 98 addressable modules per SLC SLC circuits shall be capable of supporting laser sensors ASD LS with a sensitivity setting as low as percent obscuration and the MCS Acclimate 2 sensor with intelligent compensation and integral sensor The control panels shall have the capability to accept firmware upgrades via laptop computer without requirement of replacing microchips The network shall be based on a peer to peer token ring technology operating at 625 K baud using 4 6 or 7 wiring The network shall include the capability of using either twisted pair wiring a pair of fiber optic cables to 200 microns or both to maximize flexibility in system configuration Each network node shall be capable of being programmed off line using Windows based software by Fire Control Instruments FCI Each node shall also be capable of being downloaded by the laptop computer into any other node in the system Each network node shall be capable of being grouped with any number of additional nodes to produce allowing that group of nodes to act as one while retaining the peer to peer functionality slave configurations are not acceptable Each network node shall be capable of annunciating all events within its or annunciating all from the entire network on the front panel LCD without any additional equipment Each network node shall be capable of having an integral digital alarm communication transmitter that can report events in either its region or the entire network to a single account Each 7100 panel shall be capable of storing its entire program and allow the installer to activate only devices that are installed during construction without further downloading of the system Each system shall be provided with four 4 levels of password protection with up to sixteen 16 Each node shall be capable of using up to 125 Groups to allow control between different 2 PRODUCT OPERATION Multiprocessor Based system shall be of multiprocessor design to allow maximum flexibility of capabilities and operation Field Programmable system shall be capable of being either front panel programmed or by means of a Field Configuration Program allowing programming to be downloaded via computer from any node on the network RS 232C Serial Output supervised RS 232C serial port shall be provided to operate remote printers and or video terminals accept a program from a computer or provide an 80 column readout of all alarms troubles location time date etc The communication shall be standard ASCII code operating at a 9600 baud rate Control by Event CBE Program of a manual station or automatic activation of any smoke sensor heat sensor or waterflow device sh