Gamewell-FCI InnovairFlex D2 Duct Smoke Detector
File Preview
Click below to download for free
Click below to download for free
File Data
Name | gamewell-fci-innovairflex-d2-duct-smoke-detector-7032815964.pdf |
---|---|
Type | |
Size | 691.62 KB |
Downloads |
Text Preview
InnovairFlex Series Duct Smoke Photoelectric Smoke Detector Designed with photoelectric integrated low flow Air velocity rating from 100 ft min to 4,000 ft min m s to 20.32 m sec Contains a plug in sensor Offers superb false alarm immunity with the latest technology Spans broader ranges for operating temperature 4 158 and humidity 0 to 95 non condensing Built with Patented sampling tube installs from front or of the detector with no tools required Constructed with versatile mounting options for square rectangular configurations with modular construction a cover tamper feature to indicate a trouble for a removed or an improperly installed cover Has increased wiring space with a newly added inch knockout Displays improved LED status Loads current at 24 VDC 3242 1653 0206 S911 InnovairFlex Series D2 2 wire photoelectric duct detector features a pivoting housing that fits various both square and rectangular footprints mount round or rectangular duct work The InnovairFlex are the only duct smoke detectors flexible enough fit configurations from square to rectangular and every in between new duct smoke detector senses airflow speeds rang from 100 to 4,000 feet per minute with proven System precision The enhancements built into this model false alarm immunity with plug in sensor head operating temperature 4 to 158 and humid 0 to 95 percent non condensing ranges while simplify the installation and the maintenance These advance detect smoke in the harshest duct applications new design provides more wiring space with an added inch conduit knockout Numbers and labels for terminal are consistent with previous Innovair models new sampling tube can be clicked into position with smooth motion from either the front or the back of the InnovairFlex Series D2 duct smoke detector has sig to indicate trouble and maintenance conditions Addi a cover tamper feature is incorporated to indicate a condition for a removed or improperly installed sen cover An improved cover design with an integrated feature isolates the sensor head from the low technology for simple maintenance InnovairFlex Series is designed for greater flexibility reliable smoke detection to simplify installation and The new InnovairFlex product line is back compatible to existing Innovair models including test accessories Duct smoke detectors have specific SMOKE DETECTORS ARE a substitute for an open area smoke detector a substitute for early warning detection and NOT a for a building regular fire detection system to NFPA 72 and 90A for additional duct smoke application information Series is a registered trademark and InnovairFlex is a trademark of International Inc GAMEWELL FCI are for information only are not intended for installation purposes and are subject to change without notice No responsibility is assumed by Gamewell FCI for their use Clintonville Road Northford CT 06472 1610 USA Tel 203 484 7161 Fax 203 484 7118 by Honeywell International Inc All rights reserved www gamewell fci com Rev C page 1 of 4 Duct Smoke Detector Specifications Specifications air duct smoke detector shall be a System Sensor InnovairFlex D2 Photoelectric Duct Smoke Detector The detector housing be UL Listed per UL 268A specifically for use in air handling systems The flexible housing of the duct smoke detector fits both and rectangular footprints The detector shall operate at air velocities of 100 ft min to 4,000 ft min 0.5 m sec to 20.32 m sec unit shall be capable of providing a trouble signal in the event that the sensor cover is removed or improperly installed It shall be of local testing via magnetic switch or remote testing using the RTS151KEY remote test station Terminal connections shall of the strip and clamp method suitable for 12 AWG wiring Specifications Dimensions Dimensions Temperature Range to 158 to 70 Temperature Range to 158 to 70 Humidity Range to 95 relative humidity non condensing Duct Velocity to 4000 ft min 0.5 to 20.32 m sec in 37 cm Length 5 in 12.7 cm Width 2.5 in 6.6 cm Depth in 19.7 cm Length 9 in 22.9 cm Width 2.5 in 6.35 cm Depth Ratings supply voltage capacitance voltage time with RTS151 time by power down up time response time Test Requirements standby current standby current alarm current VDC max VDC min to 0.3 sec sec max sec max sec detector label average mA Current Loads at 24 VDC mA mA mA mA Max mA Max mA Max the InnovairFlex Sampling Tube InnovairFlex sampling tube may be installed from the front or back of the detector The tube locks securely into place and can removed by releasing the front or rear locking tab Figure 3 illustrates the front locking tab 1 2 3 Rev C page 2 of 4 Clintonville Road Northford CT 06472 1610 USA Tel 203 484 7161 Fax 203 484 7118 for 2 Wire Duct Smoke Detector 4 illustrates the system wiring diagram for the 2 wire duct smoke detectors powered from the initiating device circuit 4 2 Wire Duct Smoke Detector Powered from the Initiating Device Circuit Wiring Diagram 5 illustrates the wiring diagram for 2 wire duct smoke detector to the RTS151 RTS151KEY Remote Test Station 5 2 Wire Duct Smoke Detector to RTS151 RTS151KEY Wiring Diagram Notes The use of either the RTS151 or RTS151KEY requires the installation of an accessory coil DCOIL sold separately additional information refer to the InnovairFlex D2 Duct Smoke Detector Installation Instructions P N l56 3050 001R and the Application Smoke Detectors Applications Guide Clintonville Road Northford CT 06472 1610 USA Tel 203 484 7161 Fax 203 484 7118 Rev C page 3 of 4 photoelectric low flow duct smoke detector Information Number Description Number Description conventional photoelectric sensor head remote test coil required with RTS151 RTS151KEY ETX sampling tube duct width up to 1ft 0.3m sampling tube duct widths 1 ft to 2 ft 0.3 to 0.6 m P48 21 00 sampling tube duct widths 2 ft to 4 ft 0.6 to 1.2 m RA100Z Number Description Weatherproof enclosure exhaust tube duct width 1ft 0.3m magnet cap for metal sampling tubes annunciator alarm LED sampling tube duct widths 4 ft to 8 ft 1.2 to 2.4 m RTS151 sampling tube duct widths 8 ft to 12 ft 2.4 to 3.7m RTS151KEY Remote test station with key lock test station Rev C page 4 of 4 Clintonville Road Northford CT 06472 1610 USA Tel 203 484 7161 Fax 203 484 7118