Gamewell-FCI Intelligent VESDA-E VEA Series Aspiration Detectors
File Preview
Click below to download for free
Click below to download for free
File Data
Name | gamewell-fci-intelligent-vesda-e-vea-series-aspiration-detectors-5309784162.pdf |
---|---|
Type | |
Size | 1.31 MB |
Downloads |
Text Preview
Aspiration Detectors VESDA E VEA Series Detectors VESDA E VEA series of detectors provide point addressable early warning detection with pinpoint addressability These detectors use microbore air tubes and patented air sampling points with three alarm sensitivity settings the sampling points Intelligent VEA supports 40 sampling points on a single detector With a wide range of features the Intelligent VEA provides flexibility programmability enhanced connectivity and reduced total cost of ownership VEA detector features a robust IP40 rated enclosure and is equipped with a pump that provides individual microbore tube lengths up to 328 ft 100 m is fully supported by the Xtralis VSC VSM software which facilitates ease of system and maintenance During commissioning the normalization process the flow performance parameters Local smoke test ports are used during to verify that the system is fully operational Field replaceable filter smoke module pump and rotary valve components result in less down time and ease maintenance VESDA E VEA 040 A10 GW models are available 40 point VEA with LED only VEA 040 A00 GW or LED and LCD display VEA 040 A10 GW They provide standard coverage to protect up to 36,000 sq ft 3,345 sq m subject to system design and local regulatory requirements LCD display provides a range of status information including alarm and fault conditions as well as smoke level Screens for each type of are available using a simple navigation system detectors are compatibly listed for use with the E3 and S3 fire alarm control panels and operate in Velociti mode only BENEFITS Pinpoint addressability Automatic tube end to end integrity 40 addressable tubes with sampling Interruption free operation centralized testing maintenance Sampling point and blockage and sampling presence and point at set Three sensitivity for the points Variable length tubes up to ft 100 m Laser based absolute detection Coarse particle filtering clean air barrier for protection Reliable linear pump Xtralis VSC and VSM software support iVESDA application for monitoring on devices Local host mode USB Easy cable termination LEDs for alarm and signaling Easy mounting with support bracket Event Log 20,000 3.5 color touchscreen status review Seven pre configured Two GPIs monitored with fix to detector function Field replaceable filter sensor module and rotary valve Ethernet 100BASE T WiFi 802.11 b g n and S3 Capabilities Displays the real time read status of percent of alarm Put Intelligent VESDA E VEA Series detectors into Service Mode the device down for maintenance Reset airflow baselines for an Intelligent VESDA E VEA Series Listings and Approvals listings and approvals below apply to Intelligent VESDA E VEA In some cases certain modules or applications may not listed by certain approval agencies or listing may be in process factory for latest listing status Listed S5198 Vol 21 7259 1728 0503 Line Information Intelligent aspiration with LED display 40 point detection points Covers 36,000 square feet Velociti Intelligent aspiration with LED and LCD display point addressable detection points Covers 36,000 square feet it works VEA detector draws a combined air sample from a network of up 40 microbore flexible tubing from all sampling points in the area then filters and analyzes the sample in laser detection in the smoke sensor module When smoke particles are and the smoke level reaches set alarm thresholds the will raise appropriate alarm conditions After a Fire Alarm Fire is raised the system will sequentially scan the sampling locations the rotary valve to identify one or more sampling locations with the alarm event To assist in investigation of the source of a fire if the is in Pre Alarm the user can initiate a smoke scan of all locations VEA vacuum pump provides superior detection times for long lengths The system monitors the airflow within the installation detection of breakages or blockages of individual sampling and sampling tubes with faults indicated on the fire alarm panel Alarms and fire location are signaled to the fire panel the SLC loop Ethernet and WiFi can be used for configuration and monitoring and a USB interface is provided for field and maintenance Intelligent VESDA E VEA Series detector connects to the SLC loop compatible intelligent fire alarm control panels using Velociti to communicate up to five levels of events for display and in control by event system programming It also provides sampling point events directly on the fire alarm control the SLC connection the system operator can also review status information such as alarms and faults The system can also put an Intelligent VEA Series detector into service or reset airflow baselines VEA Series detectors support three sensitivity settings with alarm levels Day Night Weekend mode enables technicians to alarm thresholds based on routine changes in the and Configuration detectors offer Ethernet and WiFi connectivity as standard The detector can be added to a corporate network allowing enabled mobile devices and PC installed with Xtralis and monitoring applications VSC VSM iVESDA to wirelessly to the detector via the network VSC is used for and VSM is used for both configuration and monitoring is used for remote monitoring on mobile devices Capabilities VEA 040 A00 GW and VEA 040 A10 GW connect to the Signaling Circuit SLC loop of the E3 and S3 Uses 41 detector SLC addresses Sensitivity setting for all event are programmed with the VSC or VSM applications Detector trouble reporting at panel Interface Display Zone Number Name This button is disabled and Alarm Threshold Levels 2 1 OK Fault Fault Fault Fault Fault Chamber Fault Fault Module Fault is a registered trademark of International Inc by Honeywell Inc All rights Unauthorized use of this is strictly prohibited document is not intended be used for installation We try to keep our information up to and accurate We cannot all specific applications anticipate all requirements specifications are subject to without notice VESDA E VEA Series Technical Specifications voltage Consumption 24VDC VDC 24V Nominal operation alarm current scan mode current consumption operation alarm WHD Conditions Tube Size Tube Length Monitoring Rating Access Termination Interfaces Features Alarm Thresholds at the Sampling Point Vacuum Pump in x 13.2 in x 5.33 in 352 mm x 336 mm x 135.5 mm lbs 9.9 kg lbs 10 kg 32 to 102 0 to 39 Air 32 to 122 0 to 50 5 to 95 RH non condensing Diameter OD 6 mm ID 4 mm Diameter OD 4 mm ID 2.5 mm Diameter 98 ft 30m to 328 ft 100 m per tube Diameter Up to 49ft 15 m per tube sampling point and single tube blockage and breakage detection with scanning at intervals pre configured relays Contacts rated 2 A 30 VDC Resistive x 25 mm 1 cable entries Terminal blocks 0.2 sq mm 24 14 AWG and Action two pre alarm levels 1.6 m 0.5 ft 4.0 m 1.3 ft 8.0 m 2.5 ft 2.0 Ethernet RJ45 WiFi 802.11 b g