Gamewell-FCI IPGSM-4G IP Internet & GSM (4G 3G 2G) Dual Path Communicator

File Preview
File Preview
Click below to download for free

Text Preview

Accessories Internet and GSM Dual Path Communicator IPGSM 4G is a 4G Fire Alarm Communicator that offers Contact ID reporting that in conjunction with any Fire Alarm Control Panel FACP that has a built in This easy to install dual path communicator connects directly to the primary secondary communication ports of a Fire Panel Digital Alarm Communicator DACT It offers three selectable reporting paths which include the Cellular only IP only IP primary cellular backup the event of an off normal condition the fire panel sends the Contact ID formatted to the IPGSM 4G Communicator Panel The IPGSM 4G then reformats data into highly encrypted Ethernet packets that are used for transmission to the Receiver via either the customer provided Internet Intranet connection or the Global System for the Mobile Communications GSM network communication methods are critical in the marketplace due to the VoIP over IP migration from POTS Plain Old Telephone Service and the growth of digital radio networks The IPGSM 4G exclusive dual path communications combines Internet service with GSM to offer an added reliability and an extra of security signals from the IPGSM 4G Communicator Panel are delivered to Honeywell Network Control Center which routes the information to the appropriate Station The state of the art AlarmNet Network Control Center is fully and monitored 24 7 AlarmNet has the capability to route messages using and 800 PLUS Services providing true redundancy and multi path delivery IPGSM 4G is designed to operate over the most common GSM networks Its platform technology automatically chooses the best available cellular in the area based on the signal strength and it seamlessly self adjusts to critical life safety communications BENEFITS Saves the cost of two phone lines Offers dual path that communicate to a Station using Internet or the technology Includes a Base connection or WAN DSL or cable Requires no change to existing Fire Alarm Panel The connects to the primary secondary ports Operates over any type customer provided 10 100 Uses a 7720P Hand programmer for setup Transmits over the Supports both dynamic Diagnostic LEDs HSPA 4G HSPA HSDPA HSUPA 3G EDGE 2G GPRS 2G Data transmits over a Contact ID and it is with the Advanced Standard 256 bit or Public and Static IP Provides a built in supply module has the following An on board charging circuit design that accommodates the back up battery The primary power and the battery supervision strength and indications Reliable connection IP GSM connection every day QOS Quality of Service via conveys vital including following the time a message was received signal strength message path used Compliance comply with UL Standard 864 NFPA ensure the installation requirements are met IPGSM 4G must be installed in accordance with 72 National Fire Protection Association Standards 70 IPGSM 4G must be mounted in the same room and 20 feet of the fire panel IPGSM 4G and all equipment used for the IP such as the router hub modem etc comply with the following Listed Powered from an un switched branch circuit Provided with the appropriate standby power IPGSM 4G must use the 7A H battery not supplied provide 24 hour backup capability IPGSM 4G Communicator can be pre using the 7720P Programmer that allows to enter all central station information This is saved to the IPGSM 4G Communicator memory When the IPGSM 4G Communicator is at the site and it is connected to the Internet it registers itself with the AlarmNet Receiver most installations the only required parameters Primary City ID two digits obtained from your station Primary Central Station ID two digits obtained from monitoring station Primary Subscriber ID four digits obtained from monitoring station Communication Module MAC ID and MAC CRC located on the outside of the box and the of the module All parameters are assigned by the monitoring Information Internet and GSM Cellular Communicator the following cabinet with key outlet box Capture Module Communications Module and mounting adapter Boost Power Supply Antenna Cable IPGSM 4G 50 FT Coax Antenna Cable IPGSM 4G 25 FT Coax 3 dB External Remote Weatherproof Handheld Programmer IPGSM 4G Plug in transformer box Battery 12 Volts 7 A H Sealed Technical Specifications Transformer Operating Voltages 120 VAC 60 Hz 0.50A 18 VAC 50 VA Battery 12 V 7.0 A 24 hours standby Requirements 230 mA standby mA during transmission Power 850 MHz 1 Watt MHz 2 Watts 12.75 x 14.875 H x 3.0 D W x 37.6 H x 7.6 D cm Temperature 32 F to 120 F C to 49 C 0 93 non condensing AND HU1MIDITY RANGES system meets NFPA requirements for operation at 49 120 and at a relative humidity 93 RH non condensing at 32 2 90 3 the useful life of the system standby and the electronic components may be affected by extreme temperature ranges and Therefore it is recommended that this and its peripherals be installed in an with a normal room temperature of 15 80 IPGSM 4G is designed to comply with the standard Standard UL 864 9th Edition LISTINGS AND APPROVALS listings and approvals apply to the modules in this document In some cases certain or applications may not be listed by certain agencies or listing may be in process the factory for the latest listing status Listed S1869 Approved FDNY COA 6162 7165 1703 0176 of Chicago Approved Class 1 Certificate of Compliance VMA 45894 02C 9001 Certification a complete listing of all approvals and please visit is a registered of Honeywell Inc is a registered trademark Underwriters Laboratories document is not intended be used for installation We try to keep our information up to and accurate We cannot all specific applications anticipate all requirements specifications are subject to without notice more information more about Gamewell FCI IPGSM 4G and other available by visiting www Gamewell FCI com Gamewell FCI Clintonville Road CT 06472 1610 B 07 17 Honeywell International Inc

Related Files