Gamewell-FCI L-Series Chimes and Chime Strobes

File Preview
File Preview
Click below to download for free

File Data

Name gamewell-fci-l-series-chimes-and-chime-strobes-9082753641.pdf
Type PDF
Size 758.87 KB
Downloads

Text Preview

Notification Appliances Chimes and Chime Strobes Chimes and Wall Ceiling Mount Chime Strobes L Series selectable output wall mount and ceiling mount Chimes and Chime include a variety of features that increase their application versatility while the installation In addition this product includes lower current draws and modern aesthetic design which reduce installation times and maximize profits The white and red plastic housings allow the L Series devices to meet virtually any requirement selectable output chimes and chime strobes are private mode notification used to alert trained personnel to investigate possible emergency and to take appropriate action Security guard and nurse workstations are locations to install chime products devices offer a plug in design so that there is minimal intrusion into the backbox design feature makes the installation fast and foolproof while eliminating costly time consuming ground faults can easily adapt devices to a wide range of application requirements using following Field selectable candela settings Automatic selection of 12 or 24 volt operation Rotary switch to set chime tones and two volume selections and Chime Strobes BENEFITS Built with an updated Uses field selectable settings aesthetic Features a plug in that allows intrusion into backbox Contains a mounting with a shorting feature that the wiring before the installation 15 30 75 95 110 135 185 15 30 75 95 115 150 177 Provides an automatic of 12 or 24 operation at 15 30 candela Uses a rotary switch for and volume Five selectable tones high and low settings Supports the electrical with the products SpectrAlert and Advance Wall models listed for mounting only models listed ceiling mounting Includes a captive screw Designed with a Current Draw 1 lists the UL maximum Horn current draw Sound Second Chime Second Chime Second Chime Second Chime Chime Chime Second Whoop Second Whoop This data represents coding at 3 chimes per second current draw will vary depending upon coding selected Volts 16 33 Volts FWR 39 43 39 42 43 1 UL Max Horn Current Draw mA RMS Current Draw Data 2 lists the maximum UL Current Draw mA RMS allowed for Chime Strobe Ceiling Volts Volts Input Second Chime Second Chime Second Chime Second Chime Chime Chime Second Whoop Second Whoop Input Second Chime Second Chime Second Chime Second Chime Chime Chime Second Whoop Second Whoop Volts 2 UL Max Chime Strobe Current Draw mA RMS Ceiling Current Draw Data 3 lists the maximum UL Current Draw mA RMS allowed for Chime Strobe Wall Volts Input Second Chime Second Chime Second Chime 90 Second Chime 89 Chime Chime Second Whoop Second Whoop Volts Input Second Chime Second Chime Second Chime Second Chime Chime Chime Second Whoop Second Whoop Volts 3 UL Max Chime Strobe Current Draw mA RMS Wall Strobe Tones and Sound Output Data select the chime tone use the rotary switch on the of the product The current draw and sound for various chime tone settings are in Table 4 Level Second Chime Second Chime Second Chime Second Chime Low Chime Chime Second Whoop Second Whoop For Chimes only 4 Horn Strobe Tones and Sound Date Strobe Tones and Sound Output Data current draw and sound measurements for various tone settings are listed in Table 5 Second Chime High 61 Second Chime 56 Second Chime High 67 Second Chime Low 61 Chime High 64 Chime 59 Second Whoop High 76 Second Whoop Low 62 57 FWR 62 55 70 61 66 60 78 64 57 5 Chime and Chime Strobe Output Dimensions 1 illustrates the Chimes dimensions 2 shows the Chime Strobe dimensions 3 shows the Ceiling Chime Strobe 1 Chimes 2 Chime Strobe 4 shows the SBBRL dimensions 5 shows the SBBCLRL dimensions 3 Ceiling Chime Strobe 4 SBBRL 5 SBBCLRL Ordering Information Chimes Wall Ceiling Chimes Strobes Chime Wall Red Chime Wall White Chime Strobe Wall Red Chime Strobe Wall White Chime Strobe Ceiling Red Chime Strobe Ceiling White Ordering Information Surface Mount Back Box Wall Red Surface Mount Back Box Wall White Surface Mount Back Box Ceiling Red Surface Mount Back Box Ceiling White Chimes and Chime Strobes Technical Specifications L Series Chimes and Chime Strobes are designed to with the following standard Standard UL 1971 and UL 464 LISTINGS AND APPROVALS listings and approvals apply to the modules in this document In some cases certain or applications may not be listed by certain agencies or listing may be in process Consult for latest listing status S5512 S4011 7135 1653 0503 9001 Certification a complete listing of all approvals and please visit Series and Gamewell FCI registered trademarks of International Inc is a registered trademark Underwriter Laboratories document is not intended be used for installation We try to keep our information up to and accurate We cannot all specific applications anticipate all requirements specifications are subject to without notice 49 Specifications Operating Temperature 32 to 120 0 Range 10 to 93 non condensing Flash Rate 1 flash per second Voltage Regulated 12VDC or regulated Voltage Range2 8 to 17.5V 12V nominal or 16 to 33V 24V nominal Voltage Range MDL3 Sync Module 8.5 to 17.5V 12V nominal or 16.5 to 33V 24V nominal Terminal Wire Gauge 12 to 18 AWG strobe dimensions including lens 5.6 in L 4.7 in W 1.25 inD 143 mm L mm W 32 mm D Chime dimensions 5.6 in L 4.7 in W 1.25 in D mm L 119 mm W 32 mm D Chime strobe dimensions including lens 6.8 Diameter x 2.47 D Diameter x 62.7mm D red

Related Files