Gamewell-FCI L-Series, Dual Strobe Expander Plates for Emergency Communications

File Preview
File Preview
Click below to download for free

Text Preview

Notification Appliances Dual Strobe Expander Plates for Emergency Communications Expander Plate for Dual Strobe and Dual Strobe with Speaker new L Series Universal Expander Plate for Dual Strobe and Strobe with Speaker lowers costs and improves aesthetics by the functions of 2 3 devices for emergency applications L Series Universal Expander Plates cut costs speed and improve aesthetics on the emergency applications that require fire and emergency by combining the functions of two to three devices on a mounting plate and backbox L Series Universal Expander provide dual strobe and speaker strobe functionality that for a single person to wire and install Simply mount the plate a junction box attach the mounting plate and connect the field to the terminals To complete the installation hinge and the strobe or speaker strobe device with a single captured screw Universal Expander Plate for Dual Strobe and Dual Strobe Speaker is designed to be used in 12 or 24 volt DC or FWR wave rectified systems Amber lens strobes are UL 1638 Visual Signaling Appliances for Private Mode General Signaling Clear lens strobes are UL 1971 Listed Devices for Hearing Impaired for Public Mode To with UL Standard 1638 Private Mode General Utility clear lens strobes are compatible with colored lenses SpectrAlert Advance products are suitable for use in the systems The System Sensor MDL3 module may used to provide synchronization BENEFITS Plate sold Plate Shown Horn Strobe Plate with Strobe and Skirt UL 1971 Listed clear Supports the following Automatic selection of Rated from 32 to settings strobe UL 1638 Listed amber strobe Complies with DOD Listed for wall 15 30 75 95 110 135 185 Refer to the Candela for UL 1971 or 24 volt at 15 and 30 Compatible with Sensor Optional tamper Torx head included Designed to be used in or 24 volt DC or systems SEP SPSWL P is with the SPSWL SPSWL P SWL SWL P P2WL P4WL SEP SPSWL P is with the colored lens Lens A2 LENS B2 LENS G2 LENS R2 BZW BZSPW Current Draw 1 lists the UL maximum strobe current draw Volts 16 33 Volts Products set at 15 and 30 candela automatically on either 12V or 24V power supplies The products not listed for 12V DC operation when set to any other settings 1 UL Maximum Strobe Current Draw mA for P SEP SPSWL P Ordering Information Mount Universal Expander Plate Amber Lens Full Range White Compatible with all L Series wall appliances P Universal Expander Plate Full Candela White Plain Compatible with all L Series wall appliances Universal Expander Plate Back Box Skirt Compatible with SEP SPSWL and SEP SPSWL P Dimensions mm mm 1 SEP SPSWL P Expander Plate Plate with Speaker Strobe in Upper Position mm 5 0 3 5 m m 2 SPSEP BBSW Backbox Skirt 1 8 0 8 m m 7 5 9 1 m m 1 8 0 8 m m 8 6 7 4 2 m m 4 3 6 3 3 m m 3 Expander Plates with Speaker Strobe and Horn Strobe in Upper Position 4 1 4 4 m m 4 1 4 4 m m Mounting 4 SEP SPSWL P with Flush Mounted Speaker Strobe Mounting 5 SEP SPSWL P with Flush Mounted Horn Strobe P S E P B B S W L P E A K E R S T R O B E A C K B O X S K IR T L STROBE BOX SKIRT 6 SEP SPSWL P with Speaker Strobe and Backbox Skirt 7 SEP SPSWL P with Horn Strobe and Backbox Skirt Dual Strobe Expander Plates for Emergency Communications L Series Universal Dual Strobe Expander Plates for Communications are designed to comply with following standards Standards UL 1971 and UL 1638 LISTINGS AND APPROVALS listings and approvals apply to the modules in this document In some cases certain or applications may not be listed by certain agencies or listing may be in process factory for latest listing status S5512 Plates 7300 1653 0511 and Horns 3057383 Strobes 3057493 Lenses and Color Lens Kits over Clear Lenses 9001 Certification a complete listing of all approvals and please visit System and SpectrAlert are trademarks of International Inc is a registered trademark Underwriter Laboratories document is not intended be used for installation We try to keep our information up to and accurate We cannot all specific applications anticipate all requirements specifications are subject to without notice Specifications Temperature 32 to 120 0 to 49 Range 10 to 93 non condensing Flash Rate 1 flash per second Voltage strobes Regulated 12VDC FWR or 24DC FWR Voltage Range includes fire alarm panels built in sync 8 to 17.5V 12V nominal or 16 to 24V nominal Voltage with MDL3 Sync Module 8.5 to 12V nominal or 16.5 to 33V 24V nominal terminal wire gauge 12 to 18 AWG Expander Plate with Strobe or Speaker Device P L 13.05 in 331.5 mm W 5.39 in mm D 2.41 in 61.2 mm L 13.75 in 349.3 mm W 6.10 in mm D 2.5 in 63.5 mm Box Options SEP SPSWL P 4 x 4 x 2 1 8 or 4 x 4 x 2 1 8 AND HUMIDITY RANGES system meets NFPA requirements for operation at 0 49 120 and at a relative humidity 93 2 non condensing at 32 2 90 3 the useful life of the system standby batteries the electronic components may be adversely affected extreme temperature ranges and humidity Therefore it recommended that this system and its peripherals be in an environment with a normal room of 15 27 80 more information more about Gamewell FCI L Series Dual Strobe Plates for Emergency Communications and other available by visiting www Gamewell FCI com Gamewell FCI Clintonville Road CT 06472 1610 A 07 18 Honeywell International Inc

Related Files