Gamewell-FCI L-Series Indoor Ceiling Speaker Strobes and Dual Speaker
File Preview
Click below to download for free
Click below to download for free
File Data
Name | gamewell-fci-l-series-indoor-ceiling-speaker-strobes-and-dual-speaker-2498136507.pdf |
---|---|
Type | |
Size | 843.45 KB |
Downloads |
Text Preview
Notification Appliances Series Indoor Ceiling Strobes and Dual Speakers Output Speaker Strobes and Dual Speakers for Ceiling Applications L Series indoor selectable output speaker strobes and dual voltage evacuation offer a modern aesthetic plug in design that reduce costly ground faults universal mounting plate can be used in ceiling applications and its flexible enables the Installer to easily perform the following Pre wire mounting plates Dress the wires wiring continuity before the Installer plugs in the speakers In addition this includes a protective plastic cover which shields exposed speaker and prevents nicked wires These devices enable faster installations by instant feedback to the Installer to ensure the following The wiring is properly connected The rotary switches are set to the selected voltage and power settings The 7 field selectable candela settings are configured for wall speaker strobes The low total harmonic distortion of the SP speaker offers both high fidelity and sound output so that it can be used in high ambient noise makes installation easy to install the L Series speakers or speaker strobe do following Attach a universal mounting plate to a 4 x 4 x 2 1 8 inch backbox Flush applications do not require an extension ring Speaker Strobes Connect the notification appliance circuit or speaker wiring to the terminals on the mounting plate To attach the speaker or speaker strobe to the mounting plate insert the product tabs into the mounting plate grooves Hinge the device into position to lock the product pins into the mounting plate terminals A catch temporarily holds the device in place until you secure the device with a captured mounting screw BENEFITS Includes a plug in Field selectable Uses an automatic Offers speakers with Built with an updated settings on units of 12 or 24 operation at 15 30 candela high fidelity and sound Provides a rotary Compatible with the design and protective to reduce ground Contains a universal plate with an shorting that is used to the wiring before an No extension ring 15 30 75 95 115 150 177 that simplifies field selection of voltage 25 70.7 VRMS and the power 1 4 watt 1 2 watt 1 watt 2 watts Sensor Supports electrical with the SpectrAlert the SpectrAlert products Designed with a Current Draw Data 1 lists the UL maximum strobe current draw Volts 16 33 Volts 1 UL Max Strobe Current Draw mA RMS 2 lists the ceiling mount speaker sound outputs Reverberant 10 ft Anechoic 10 ft W W W W 2 Ceiling Speaker Sound Outputs 3 lists the ceiling mount speaker strobe sound Reverberant 10 ft Anechoic 10 ft W W W W 3 Ceiling Mount Speaker Strobe Sound Output Speaker and Speaker Strobe Specifications Specifications L Series speaker and speaker strobes shall mount a 4 x 4 x 2 1 8 inch backbox A universal mounting shall be used for the mounting ceiling and wall The notification appliance circuit and wiring shall terminate at the universal plate Also the L Series speaker strobes when used with the Module accessory shall be powered from non coded notification appliance circuit output and operate on a nominal 12 or 24 volts When these are used with the Sync Module either the following may occur 12 volt rated notification appliance circuit outputs operate between 8.5 and 17.5 volts 24 volt rated notification appliance circuit outputs operate between 16.5 and 33 volts 95 30 150 75 177 Indoor L Series products shall operate between F and 120 from a regulated DC or full wave unfiltered power supply Speaker strobes shall the following field selectable candela settings 15 115 speaker shall be an L Series model dual transformer speaker capable of operating at or 70.7 nominal VRMS It should be listed to UL 1480 and shall be approved for fire service The speaker shall have a frequency of 400 to 4,000 Hz and shall have an operating between 32 and 120 The speaker have power taps and voltage that are selected by switches Strobe Combination speaker strobe shall be an L Series model listed to UL Standard 1480 and UL 1971 and be approved for fire protective systems The speaker shall be capable of at 25.0 or 70.7 nominal VRMS selected via switch and shall have a frequency range of 400 4,000 Hz The speaker shall have power taps that are by rotary switch The strobe shall comply with NFPA 72 requirements for visible signaling flashing at 1 Hz over the strobe entire voltage range The strobe light shall consist a xenon flash tube and associated lens reflector Module module shall be a Sync model MDL3 listed UL Standard 464 and shall be approved for fire service The module shall synchronize strobes at 1 Hz The module shall mount to 4 11 16 x 4 11 16 x 2 1 8 inch back box The shall also control two Style Y Class B circuits one Style Z Class A circuit The module shall multiple zones Daisy chaining two or synchronization modules together will all the zones they control The module not operate on a coded power supply 1 shows the speaker dimensions 1 Speaker Dimensions 2 shows the speaker dimensions Ordering Information Speakers and Strobes Mount White Speaker only Red Speaker only White Speaker Strobe Red Speaker Strobe Plain Speaker Strobe Fuego Speaker Strobe Alert Speaker Strobe Clear White Universal Ceiling Surface Mount Box Red Universal Ceiling Surface Mount Back White Universal Ceiling Trim Ring Red Universal Ceiling Trim Ring 2 Speaker Dimensions Mounting 3 illustrates the ceiling mount speaker and strobes with the SBBCR SBBCWL surface backbox 3 Ceiling Mount Speaker and Speaker Strobe SBBCRL SBBCWL Surface Mount Backbox Series Indoor Ceiling Strobes and Dual Speakers Technical Specifications Specifications to 120 0 to 49 Temperature to 93 non condensing Range in 173 mm SPC Speaker With Surface Mount BacKbox 6.9 in 176 mm in 173 mm SPSC Speaker Strobe With Surface Mount Backbox 6.9 in 176 mm in 25 mm in 89 mm in 73 mm in 136 mm Specifications Voltage speakers 25 Volts or 70.7 Volts nominal Supervisory Voltage speakers 50 VDC Flash Rate 1 flash per second Voltage strobes Regulated 12 VDC or Regulated 24 VDC FWR Voltage Range includes fire alarm panels built in sync 8 to 17.5 V 12 V nominal or 16 to V 24 V nominal Voltage with MDL3 Sync Module 8.5 to V 12 V nominal or 16.5 to 33 V 24 V nominal Range Range 400 to 4,000 Hz 1 2 watts L Series Indoor Ceiling Strobes and Horn Strobes are to comply with the following standard Standard UL 1971 and UL 464 LISTINGS AND APPROVALS listings and approvals apply to the modules in this document In some cases certain or applications may not be listed by certain agencies or listing may be in process factory for latest listing status S5512 S4011 7320 1653 0505 ISO 9001 Certification a complete listing of all approvals and please visit Series and Gamewell FCI