Gamewell-FCI L-Series Low Frequency Indoor Selectable Sounders and Sounder Strobes

File Preview
File Preview
Click below to download for free

Text Preview

L SERIES LOW FREQUENCY Selectable Low Frequency Sounders and Sounder Strobes audible visible notification products features to maximize profits with lower draw and modern aesthetics L Series offers the most versatile and easy to use line of low frequency sounder and low sounder strobes in the industry With white and red plastic housings listed for and ceiling mounting L Series Low Frequency can meet virtually any application low frequency sounder and low frequency sounder strobes were designed to address NFPA 72 sleeping space requirements that require a low frequency notification that operates within frequency range of 520 Hz 10 and is of a square wave Like the entire L Series product line they include a variety of features that increase application versatility while simplifying installation All devices feature plug in designs minimal intrusion into the back box making installations fast and foolproof while eliminating costly and time consuming ground faults further simplify installation and protect devices from construction damage L Series uses universal mounting plate with an onboard shorting spring so installers can test wiring before the device is installed can also easily adapt devices to a suit a wide range of application requirements field selectable candela settings 24 volt operation and a rotary switch for 520 Hz low sounder tones models include Wall mount sounder strobes P2RL LF P2WL P2RLA LF P2WLA LF Wall mount sounders HRL LF HWL LF HRLA LF HWLA LF Ceiling mount sounder strobes PC2RL LF PC2WL LF PC2RLA LF PC2WLA LF Ceiling mount sounders HCRL LF HCWLA LF HCRL LF HCWLA LF Compact ceiling mount sounders HGRL LF HGWL LF Compact wall mount sounders with hush function HGRLZA LF HGWLZA LF 520 Hz 10 square wave tone NFPA Rotary switch for High Low Temp3 Temp4 Compatible with Sync modules Continuous settings Sounder only also offer a Coded setting and MDL3W A HGRLZA LF and HGWLZA LF include an Plug in design with minimal intrusion into alarm indicator and silence button Compact standard and round ceiling Mounting plate shorting spring checks back box Sounders listed for ceiling and wall Round Sounder Strobes listed for ceiling continuity before device installation wall Electrically compatible with legacy Updated modern aesthetics AND BENEFITS Full candela range plus High Low tone to optimize current draw for a wide of applications Field selectable candela settings Wall 15 30 75 95 110 135 and 185 units 15 30 75 95 115 150 and and SpectrAlert Advance and provides a direct replacement HW R LF P2R WH LF and ULC listed CURRENT DRAW AND SOUND OUTPUT DATA Frequency Wall Sounder Strobe Current Draw mA and Sound Output dBA Draw mA 3 3 4 4 VDC FWR 30cd 75cd 95cd 110cd 135cd 185cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd Frequency Ceiling Sounder Strobe Current Draw mA and Sound Output dBA Draw mA 3 3 4 4 VDC FWR 30cd 75cd 95cd 110cd 135cd 185cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd Frequency Wall Sounder Strobe Frequency Ceiling Sounder Strobe Output dBA Output dBA Output Output Reverberant Anechoic V V Output Output Reverberant Anechoic V V 3 3 4 4 3 3 4 4 Low Frequency Sounder Current Draw mA RMS Draw mA Volts Output dBA Reverberant Volts Output dBA Anechoic Volts 3 3 4 4 Continuous Continuous For coded tones temporal coding must be provided by the NAC If the NAC voltage is held con the sounder output will remain constantly on Coded ratings provided are for continuous voltage 2 of 4 9021 62013 C 9 25 2020 strobes the module shall silence the low frequency sounder on frequency sounder strobe models over a single pair of wires The shall mount to a 411 16 411 16 21 8 inch back box The shall also control two Class B circuits or one Class A circuit module shall synchronize multiple zones Daisy chaining two or synchronization modules together will synchronize all the they control The module shall not operate on a coded power LISTINGS AND APPROVALS listings and approvals apply to the modules specified in this In some cases certain modules or applications may not listed by certain approval agencies or listing may be in process the factory for the latest listing status Listed S4011 Approved PR452768 Horns only 7135 1653 0516 Horn Strobes 7125 1653 0517 SPECIFICATIONS low frequency sounder and low frequency sounder strobes mount to a standard 4 4 1.5 inch back box 4 inch octagon box or double gang back box Two wire products shall also to a single gang 2 4 17 8 inch back box A universal plate shall be used for mounting products The appliance circuit wiring shall terminate at the universal plate Also L Series products when used with the Module accessory shall be powered from a non coded appliance circuit output and shall operate on a nominal or 24 volts When used with the Sync Module 24 volt notification appliance circuit outputs shall operate between and 33 volts Indoor L Series products shall operate between and 120 degrees Fahrenheit from a regulated DC or full wave unfiltered power supply Low Frequency Sounder strobes have field selectable candela settings Wall units 15 30 75 110 135 and 185 Ceiling units 15 30 75 95 115 150 and The field selectable tones will sound within the frequency of 520 Hz square wave tone and have a permanent on the housing that reads Hz Frequency Sounder low frequency sounder shall be a System Sensor L Series listed to UL 464 and shall be approved for fire service The low frequency sounder and the Sync accessory if used shall be powered from a notification circuit output and shall operate on a nominal 24 volts fire alarm panels with built in sync When used with the Module 24 volt rated notification appliance circuit shall operate between 16.5 to 33 volts If the notification are not UL 9th edition listed with the corresponding or power supply being used then refer to the compatibility of the pan

Related Files