Gamewell-FCI MMI-10 Ten Input Module

File Preview
File Preview
Click below to download for free

File Data

Name gamewell-fci-mmi-10-ten-input-module-6284310975.pdf
Type PDF
Size 1.18 MB
Downloads

Text Preview

Building Intelligent Networks The Multi Mod Ten Input Monitor mod MMI 10 provides ten Style B Class B five Style D Class A supervised Initiat Device Circuits IDCs suitable for a wide of monitoring applications Each supervised circuit may be connected any normally open contact device such manual stations tamper and supervisory waterflow switches heat detectors smoke sensors etc The MMI 10 connects to the Signaling Line SLCs of the FCI 7200 FV7200 7100 Series fire alarm control panels of the MMI 10 supervised interface cir occupies its own address on the SLC allowing each to be fully pro in its control by event sequence operation The address of the first supervised inter circuit is set with a pair of rotary dials remaining circuit is automatically as to its own subsequent address The module includes an address disable matrix that a maximum of two un addresses to be turned off to free these for other purposes An additional setting selects either Style B or Style circuit configurations Each Circuit has its own status LED that to indicate proper polling and turns steady when the output has been acti Two Multi Mod Series units can be in one MBB 2 cabinet Additional options include the MCH 6 chas that can accommodate six Multi Mod modules The MCH 6 chassis can be in a custom cabinet or can be in the MBB 6 cabinet allowing up six Multi Mod Series modules in one cabi The Multi Mod Series is ideal for applica where centralized location of circuits required As many as 60 Initiating De Circuits may be located in a cabinet is only 12.63 H x 24 W x 6.5 D in saving valuable wall space in me rooms and electrical closets and cost of installation INPUT MMI 10 Module Provides Ten Style B Class B or Five Style D Class A Individually Addressable Individually Programmable Initiating Device Circuits for Applications requiring Monitor ing of Normally Open Contact Devices Wiring Terminal Blocks allow Ease of Installation and Servicing Blocks can Accommodate 12 to 18 AWG Wire On board Jumper Configuration Feature allowing One or Two Monitoring Circuit Addresses to be Disabled for use with 7100 and 7200 Series Fire Alarm Control Panels LED Indicators for Retrofit Applications Many as Sixty Initiating Device Circuits in One 12 x 24 x 6.5 Cabinet Mounting Cabinets Available for Two MBB 2 Cabinet to Six MBB 6 Cabinet MMO 6Rs ISO 9001 Company are provided for information only and are not to be used for installation purposes and are believed be accurate However no responsibility is assumed by Fire Instruments Inc for their use Specifications subject to without notice 2002 All Rights Reserved 1.0 1 of 4 Intelligent Networks Device Circuit Terminal Blocks Style B or Five Style A to SLC and Out ADDRESS ADDRESS ADDRESS ADDRESS ADDRESS ADDRESS 1 3 5 7 9 Board Layout Address Switches First Address Nine Addresses assigned to Monitoring Circuits LEDs per Initiating Circuit to indicate Polling turn on steadily indicate Activation 9020 0538 VER 1.0 Page 2 of 4 are provided for information only and are not intended to be used for installation purposes and are believed to be accurate no resposibility is assumed by fire Control Instruments Inc for their use Specifications are subject to change without notice 2002 All Rights Reserved Southwest Park Westwood MA 02090 USA cid 127 Tel 781 471 3000 cid 127 Fax 781 471 3099 cid 127 www firecontrolinstruments com CONTROL INSTRUMENTS Inc Intelligent Networks High Wide 2 unit capacity High Wide with MCH 6 6 unit capacity are provided for information only and are not intended to be used for installation purposes and are believed to be accurate no resposibility is assumed by fire Control Instruments Inc for their use Specifications are subject to change without notice 2002 All Rights Reserved Southwest Park Westwood MA 02090 USA cid 127 Tel 781 471 3000 cid 127 Fax 781 471 3099 cid 127 www firecontrolinstruments com CONTROL INSTRUMENTS Inc 9020 0538 VER 1.0 Page 3 of 4 Intelligent Networks Voltage Current Current IDC Wire Resistance IDC Voltage IDC Current Range MBB 2 MBB 6 VDC mA mA with all ten LEDs on Ohms VDC mA F to 120 F 0 to 49 C to 85 Non condensing H x 5.8 W x 1.25 D 17.3 x 14.7 x 3.18 cm H x 9.25 W x 3.32 D 31.12 x 23.5 x 8.43 cm H x 24 W x 6.5 D 32.08 x 60.96 x 16.51 cm APPROVALS 864 INFORMATION NUMBER 10 Input Module Box 2 Unit Box 6 Unit requires MCH 6 Mounting Chassis are provided for information only and are not intended to be used for installation purposes and are believed to be accurate no resposibility is assumed by fire Control Instruments Inc for their use Specifications are subject to change without notice 2002 All Rights Reserved Southwest Park Westwood MA 02090 USA cid 127 Tel 781 471 3000 cid 127 Fax 781 471 3099 cid 127 www firecontrolinstruments com CONTROL INSTRUMENTS Inc 9020 0538 VER 1.0 Page 4 of 4

Related Files