Addressable Devices Series MMI 6SF Six Zone Interface Module Velociti Series multi mod six zone interface module MMI 6SF provides six B Class B or three Style D Class A supervised initiating device circuits IDC for use with UL Listed conventional 2 wire smoke detectors as well as any open contact device Velociti Series use a communication protocol that substantially increases the of communication between the sensors and certain Gamewell FCI analog fire alarm controls These devices operate in a grouped fashion If one of devices in the group has a status change the panel microprocessor stops the poll and concentrates on the single device The net effect is response speed up five times greater than earlier designs MMI 6SF connects to the signaling line circuits SLC of the Gamewell FCI addressable series fire alarm control panels Each of the MMI 6SF initiating circuits occupies its own address on the system SLC allowing each to be fully in its control by event sequence of operation address of the first initiating device circuit is set with a pair of rotary dials Each circuit is automatically assigned to its own subsequent address The MMI module includes an address disable jumper matrix to allow a maximum of two addresses to be turned off to free these addresses for other purposes An pair of jumpers selects either Style B or Style D circuit configurations circuit has its own status LED that flashes to indicate proper polling and lights steadily when the output has been activated Two multi series units can be mounted in one MBB 2 cabinet Additional mounting options include the MCH 6 chassis that can accommodate six series modules The MCH 6 chassis can be installed in a custom cabinet or can be mounted in the MBB 6 cabinet allowing up to multi mod series modules in one cabinet initiating device circuit of the MMI 6SF can support a maximum line resistance of up to 40 ohms allowing the use of linear heat detection The MMI 6SF is ideal for applications where centralized location of circuits is required As many as sixty initiating device circuits may located in a cabinet that is only 12.63 H x 24 W x 6.5 D in dimension saving valuable wall space in mechanical rooms and electrical closets reducing cost of installation Information Multi Mod 6 zone interface module Backbox 2 unit Backbox 6 unit requires MCH 6 6 Unit mounting chassis BENEFITS Each MMI 6SF module Suitable for use with Terminal blocks can six Style B B or three Style Class A individually Device Listed compatible conventional sensors and open contact Includes removable terminal blocks allow ease of and 12 to 18 wire Provides a flexible configuration that allows one two monitoring addresses to be Displays individual indicators Ideal for retrofit Designed to contain as as thirty six device in one 12 x 24 6.5 cabinet Offers two mounting available for MBB 2 cabinet to MBB 6 cabinet Bi color LEDs flash whenever the is addressed light steady red on Only the red LED operative in panels that not operate in Velociti Series MMI 6SF Technical Specifications Velociti Series MMI 6SF is designed to comply with following standard Standard UL 864 9th Edition LISTINGS AND APPROVALS listings and approvals apply to the modules in this document In some cases certain or applications may not be listed by certain agencies or listing may be in process factory for latest listing status S1913 3023594 FDNY 219 02 E Vol IV 7300 1703 0124 9001 Certification a complete listing of all approvals and please visit E3 Series and are registered of Honeywell Inc is a registered trademark Underwriters Laboratories document is not intended be used for installation We try to keep our information up to and accurate We cannot all specific applications anticipate all requirements specifications are subject to without notice Voltage 5 32 VDC Current 2 mA Current 40 mA with all six LEDs lit IDC Wire 25 Ohms Range 32 F to 120 F 0 to 49 C 10 to 85 non condensing 6.8 H x 5.8 W x 1.25 D 17.3 x 14.7 x 3.2 cm MBB 2 12.25 H x 9.25 W x 3.32 D 31.1 x 23.5 x 8.4 cm MBB 6 12.63 H x 24 W x 6.5 D 32.1 x 70.0 x 16.5 cm Supply Voltage DC Voltage 18 28 Volts power limited Ripple Voltage 0.1 Volts rms maximum Current 90 mA per circuit AND HUMIDITY RANGES system meets NFPA requirements for operation at 0 49 120 and at a relative humidity 93 2 noncondensing at 32 2 90 3 the useful life of the system s standby batteries the electronic components may be adversely affected extreme temperature ranges and humidity Therefore is recommended that this system and its peripherals be in an environment with a normal room of 15 27 80 more information more about Gamewell FCI Velociti Series MMI 6SF and products available by visiting www Gamewell FCI com Gamewell FCI Clintonville Road CT 06472 1610 E 11 17 Honeywell International Inc