Gamewell-FCI MMO-6SF Multi-Mod - 6 Signal Output

File Preview
File Preview
Click below to download for free

File Data

Name gamewell-fci-mmo-6sf-multi-mod-6-signal-output-8347290165.pdf
Type PDF
Size 659.90 KB
Downloads

Text Preview

Addressable Devices Series MMO 6SF Six Signal Output Module Gamewell FCI Velociti Series multi mod six signal output module MMO 6SF six Style Y Class B or three Style Z Class A supervised control circuits for a wide range of signaling applications Each supervised circuit may be as any of the following Audio speaker circui Notification appliance circuit Supervised control output Velociti Series use a communication protocol that substantially increases the of communication between the sensors and certain Gamewell FCI analog fire alarm controls These devices operate in a grouped fashion If one of devices in the group has a status change the panel microprocessor stops the poll and concentrates on the single device The net effect is response speed up five times greater than earlier designs MMO 6SF connects to the signaling line circuits SLC of the Gamewell FCI addressable series fire alarm control panels Each of the MMO 6SF control circuits occupies its own address on the system SLC that allows to be fully programmable in its control by event sequence of operation address of the first supervised output circuit is set with a pair of rotary dials Each circuit is automatically assigned to its own subsequent address The MMO module includes an address disable jumper matrix that allows one two or three to be turned off to free these addresses for other purposes An additional setting selects either Style Y or Style Z circuit configurations A wide range of are possible including 30 VDC audio input at 25 or 70.7 VRMS 125 etc More than one circuit can share a power supply if the current capacity does exceed the power supply output BENEFITS Each MMO 6SF Includes removable Provides a flexible Short circuit protection provides six Y Class B or Style Z Class A appliance supervised output terminal blocks ease of and Terminal blocks can 12 to 18 wire Contains external monitoring configuration that allows up three output circuit to be Accommodates external power Ideal for retrofit external power Sources providing AC or audio inputs Designed for use with analog series fire control panels Displays individual indicators Offers two mounting available for MBB 2 cabinet to MBB 6 cabinet Only the red LED operative in panels that not operate in mode Information Multi Mod 6 zone interface module Backbox 2 unit Backbox 6 unit requires MCH 6 output circuit on the MMO 6SF monitors its own to its power supply and will indicate a fault by address if the power source should fail MMO 6SF is also provided with short circuit to protect the external power source from circuits on the notification appliance circuit This feature can be disabled per individual if the application requires Power supply monitoring must also be disabled in such cases circuit has its own status LED that flashes to proper polling and lights steadily when the has been activated Two multi mod series units be mounted in one MBB 2 cabinet Additional options include the MCH 6 chassis that can six multi mod series modules The chassis can be installed in a custom cabinet or be mounted in the MBB 6 cabinet allowing up to multi mod series modules in one cabinet MMO 6SF is ideal for applications where location of circuits is required As many as supervised output circuits may be located in cabinet that is only 12.63 H x 24 W x 6.5 D in saving valuable wall space in mechanical and electrical closets and reducing cost of Series MMO 6SF Technical Specifications Velociti Series MMO 6SF is designed to comply with following standard Standard UL 864 9th Edition LISTINGS AND APPROVALS listings and approvals apply to the modules in this document In some cases certain or applications may not be listed by certain agencies or listing may be in process factory for latest listing status S1913 3023594 FDNY 219 02 E Vol IV 7300 1703 0124 9001 Certification a complete listing of all approvals and please visit E3 Series and are registered of Honeywell Inc document is not intended be used for installation We try to keep our information up to and accurate We cannot all specific applications anticipate all requirements specifications are subject to without notice Voltage 15 32 VDC Current 2.25 mA Current 40 mA with all six LEDs lit IDC Wire Resistance 25 Ohms Range 32 F to 120 F 0 to 49 C 10 to 85 non condensing 6 Unit mounting chassis 12.25 H x 9.25 W x 3.32 D 31.1 x 23.5 x 8.4 cm 6.8 H x 5.8 W x 1.25 D 17.3 x 14.7 x 3.2 cm 12.63 H x 24 W x 6.5 D 32 x 60.1 x 16.5 cm Supply Voltage Voltage 18 28 Volts 2 Power Limited Voltage 0.1 Volts rms maximum 90 mA per module AND HUMIDITY RANGES system meets NFPA requirements for operation at 0 49 120 and at a relative humidity 93 2 noncondensing at 32 2 90 3 the useful life of the system s standby batteries the electronic components may be adversely affected extreme temperature ranges and humidity Therefore is recommended that this system and its peripherals be in an environment with a normal room of 15 27 80 more information more about Gamewell FCI Velociit Series MMO 6SF other products available by visiting www Gamewell FCI com Gamewell FCI Clintonville Road CT 06472 1610 E 11 17 Honeywell International Inc

Related Files