Gamewell-FCI MS-7 Series Manual Fire Alarm Station

File Preview
File Preview
Click below to download for free

File Data

Name gamewell-fci-ms-7-series-manual-fire-alarm-station-6394701852.pdf
Type PDF
Size 670.57 KB
Downloads

Text Preview

Addressable Devices Series Fire Alarm Pull Stations Gamewell FCI MS 7 Series manual fire alarm pull stations are available in a wide of configurations The pull stations comply with the Americans with Disabilities ADA 5 lb maximum pull force requirement Operating instructions and Braille are engraved in the handle All pull stations include a key lock reset which is keyed with the Gamewell FCI fire alarm control panels and other manual fire alarm pull Velociti Addressable Station MS 7AF Velociti Series addressable station is a double action pull station for installation in the signaling line circuit of Gamewell FCI analog control panels Activation of the pull station causes its assigned address register at the fire alarm control panel The door contains an LED which flashes in normal condition and lights steady red when the station has been activated station features screw terminals Series Velociti Addressable Station MS 7ASF Velociti Series addressable pull station is a single action station for installation in the signaling line circuit of Gamewell FCI analog control panels Activation of the station causes its assigned address to at the control panel The door contains an LED which flashes green in normal condition and lights steady red when the pull station is The station features screw terminals Velociti Series pull stations use a communication protocol that substantially increases the speed of communication between the sensors certain Gamewell FCI analog addressable fire alarm controls These devices operate in a grouped fashion If one of the devices in the has a status change the panel microprocessor stops the group poll and focuses on the single device The net effect offers a response up to five times greater than earlier designs Double Action Station MS 7 double action pull station is used with conventional fire alarm control panels It features a set of single pole contacts and screw for connection to an initiating circuit BENEFITS Addressable stations with all analog fire alarm Conventional stations for use with UL Listed control The pull stations MS Offers surface or semi are Listed for applications mounting Shock and vibration Complies with ADA pull requirements Includes a tumbler lock test and reset keyed with analog fire alarm the red LED is in panels that not operate in Velociti Both single and double pull stations NYC Plate provides the backplate for the manual station See Figure 1 1 NYC Plate Information Double action station Velociti addressable double action station Velociti addressable single action station Single action station wire leads Double action station English and Spanish Agent release station dual action Agent release station with abort switch indicators dual action Double action station outdoor use SB I O Indoor outdoor use backbox Indoor outdoor use backbackbox Surface backbox Trim ring for semi flush mount plastic NYC backplate for manual pull station use with the Gamewell FCI analog addressable panels only Single Action Station MS 7S single action pull station is used with fire alarm control panels It features a set single pole contacts and wire leads for connection to initiating circuit Double Action Station MS 7SP is a double action pull station similar to MS 7 station with the additional feature of both English and Spanish instructions into the unit Dual action Agent Release Station MS 7LR is designed for use with the Gamewell FCI alarm control panels with releasing capabilities Flex Series releasing systems It features a set of pole contacts and screw terminals used to to an initiating circuit Agent Release Station with Abort MS 7LRA is designed for use with the Gamewell fire alarm control panels with releasing capabilities Flex Series releasing systems where system abort are required It consists of the following An MS 7LR mounted on a plate with an abort switch LED indicators that signal system normal and activated status Double Action Station Listed for Outdoor MS 7LOB station must be mounted on a Model backbox In retrofit applications the pull is UL Listed for use with the WP 10 backbox It intended for use with conventional control panels has a set of single pole contacts and screw MS 7 interior pull stations may be surface or semi flush mounted on a standard or 4 inch 10.2 cm square electrical box optional trim ring BG12TR may also be used for mounting Series Technical Specifications Lexan Ratings 0.25 amps 30 VAC VDC resistive 5 5 8 H x 4 1 4 W x 1 1 4 D 14 x 10.1 x 3.2 cm Temperature MS 7ASF 32 to 120 F 0 to 49 C 30 to 150 F 35 to 66 C Humidity MS 7ASF 10 to 93 non condensing 85 5 86 3.6 30 2 C Current 0030 amp 0.007 for LED Current MS 7ASF 00030 amps AND HUMIDITY RANGES system meets NFPA requirements for operation at 0 49 120 and at a relative humidity 93 2 noncondensing at 32 2 90 3 the useful life of the system s standby batteries the electronic components may be adversely affected extreme temperature ranges and humidity Therefore is recommended that this system and its peripherals be in an environment with a normal room of 15 27 80 MS 7 Series is designed to comply with the following Standard UL 864 9th Edition LISTINGS AND APPROVALS listings and approvals apply to the modules in this document In some cases certain or applications may not be listed by certain agencies or listing may be in process factory for latest listing status S2465 3023594 FDNY 67 02 E Vol VII 9001 Certification a complete listing of all approvals and please visit is a registered of GE Plastics a of General Electric and Gamewell FCI registered trademarks of International Inc is a registered trademark Underwriter Laboratories document is not intended be used for installation We try to keep our information up to and accurate We cannot all specific applications anticipate all requirements specifications are subject to without notice more information more about Gamewell FCI MS 7 Series and other available by visiting www Gamewell FCI com Gamewell FCI Clintonville Road CT 06472 1610 F 11 17 Honeywell International Inc

Related Files