Gamewell-FCI OSI-RI-GW Intelligent Beam Smoke Detector

File Preview
File Preview
Click below to download for free

File Data

Name gamewell-fci-osi-ri-gw-intelligent-beam-smoke-detector-1964032857.pdf
Type PDF
Size 720.63 KB
Downloads

Text Preview

The OSI RI GW single ended beam smoke detector easy to install and adjust Only the head unit needs be wired and the can be aimed without the detector mounting Single ended Reflective Imaging Beam Smoke Detector OSI RI GW delivers rapid installation detection and a minimalist for challenging open area OSI RI GW intelligent addressable reflector type linear optical beam smoke detector is suited for protecting large open areas with high ceilings where spot type smoke are difficult to install and maintain Ideal applications are warehouses malls hangers arenas and concert halls The beam operates primarily on the principle of obscuration using infrared The OSI RI GW detector is a combined transmitter receiver is compatible with 7075 Series S3 Series and E3 Series fire alarm control panels in mode and Easy Alignment the imager to the reflector is extremely intuitive fast and accurate thanks to the imager contained in a movable that can move vertically and horizontally LED arrows help the user find the imager perfect alignment with the reflector Once optimum alignment is found indicated by all green arrows the lens is locked with a slide A paintable cover is then placed over the front to secure the lever in locked position to Building Movement Sunlight and Foreign Object Intrusion receiver imager automatically tracks the reflector in case of building movement or structure movement This allows the OSI RI GW to be highly resistant to movement the number one cause of false alarms and or faults with traditional beam filtering high speed image acquisition and intelligent software algorithms provide system with highly improved resistance to false alarms from sunlight reflected sunlight any other very bright light sources Advanced smoke imaging techniques allow the to avoid false alarms from partial and sudden blockage from foreign object Automatic Sensitivity Setting in the market the sensitivity of the detector is selected and set automatically at the sensitivity based on the size of the reflector measured in the field of view Compensation detector will adjust its detection thresholds in line with any long term signal reduction of beam caused by dust or other contamination of the optical surfaces with Built in Imager Heater imager ships standard with an internal heating option to prevent condensation on the surface External power supply required AND BENEFITS Combined transmitter receiver unit Wide 12 field of view Fast easy and intuitive beam alignment by LED directional arrows 50 horizontal and 20 vertical beam Resistant to building movement tolerates 1 movement Resistant to strong light sources does not when saturated by sunlight Resistant to solid object intrusion Remote test station capable for electronic Long range coverage of 16 328 ft 5 100m smoke test from ground level standard no separate long range kit bottom Status LED indicators visible from the front Automatic sensitivity threshold level setting Automatic drift compensation Paintable housing cover Removable plug in terminal blocks Built in imager heater Optional reflector heater kit available Series Gamewell FCI and are registered trademarks Honeywell International Inc document is not intended to be for installation purposes We to keep our product information and accurate We cannot all specific applications or all requirements All are subject to change notice of origin Mexico TECHNICAL SPECIFICATIONS Detector Height 6 152.4 mm 10 254 mm Depth 4.5 114.3 mm Reflector Height 9.06 230 mm 7.87 200 mm Installed 2.48 lbs 1.12 kg Shipping 3.91 lbs 1.77 kg Gauge for Terminals 14 AWG 2.08 mm Voltage Range 24 VDC 15 VDC 32.0 VDC Standby Current mA 32 VDC mA 24 VDC mA 15 VDC Alarm Current LED on mA 32 VDC mA 24 VDC mA 15 VDC Devices per SLC Loop number of OSID R devices are limited due to current draw restrictions Current draws above must be considered in coordination any other devices on a circuit In general this the number of OSID R detectors to up to 4 per loop on a dedicated circuit on panels Any non beam devices distances or higher gauge wiring on circuit will decrease available current and capacity of OSID R detectors panel current 7075 Series 165 ma supervisory current 7100 Series 90 ma supervisory current E3 Series 100 ma supervisory current S3 Series 100 ma supervisory current Range 15 to 32 V Current 450 mA Max at 32 V Consumption W 24 V W 32 V Range 10.2 to 32 VDC Range 9 mA Min to 11 mA Max Temperature UL Listed for use from to 100 0 to 37.8 Temperature Range 4 to 131 to 55 Range 0 to 95 relative humidity Range 16 ft to 328 ft 5 m to 100 m Angle 20 degrees vertical 50 horizontal Levels Level 1 25 Level 2 30 3 40 Level 4 50 Features Local alarm test switch alarm reset switch Remote test and reset compatible with RTS151 and test stations OSID R test filter Detector Spacing On smooth ceilings feet between projected beams and not than one half that spacing between a beam and a sidewall Other spacing be used depending on the ceiling height characteristics and response See NFPA 72 LISTINGS S911 PR449231 7260 1703 0506 LINE INFORMATION Intelligent imaging beam smoke including reflector Laser alignment tool Test filter 10 pack Remote test station Test and reset station with key lock mount Heater kit for the reflector Multi mount accessory for ceiling or mounting with additional mounting Gamewell FCI Clintonville Road CT 06472 1610 D 07 20 Honeywell International Inc

Related Files