Gamewell-FCI PID-95 Series Point Identification Device

File Preview
File Preview
Click below to download for free

File Data

Name gamewell-fci-pid-95-series-point-identification-device-6971052483.pdf
Type PDF
Size 621.47 KB
Downloads

Text Preview

Addressable Devices PID 95 Identification Device Gamewell FCI PID 95P addressable Point Identification Device is the interface the non powered normally open dry contact devices It is designed to with the Gamewell FCI 600 Series and ILI95 E3 Series of analog fire alarm control panels FACPs Point Identification Devices monitor a Style B circuit and they are designed to be mounted in an electrical backbox PID 95P can be surface or flush mounted and it has a visible LED for alarm Point Identification Device connects to the Signaling Line Circuit SLC via two The PID 95 will monitor via a two wire supervised SLC circuit contact type such as a water flow switch or a manual station Upon activation of the device the PID 95 will report its address to the 600 Series or ILI95 E3 FACP via the analog SLC The fire alarm control panel will then activate into all programmed outputs related to the PID 95 program the PID 95 set a single DIP switch on the device printed circuit board the DIP switch to set the address of the device and the priority interrupt DIP SW To program the 600 Series or ILI95 Series use the laptop computer to program use the control panel Operator display Application PID 95 is the interface between the dry contact type devices and the SLC of the alarm control panel Use the PID 95 to connect and to identify monitor points the use of conventional input modules at the main control panel The use of can dramatically reduce the field wiring required on many projects Information Addressable point identification device for monitoring contact devices Addressable input interface device mounted on 4.688 11.908 cm plastic plate Trim ring for flush mounting on the PID 95P PID 95P PID 95 BENEFITS Compatible with the 600 and ILI95 E3 Systems Offers a plate mounted available for or flush in the dimensions 4 x 4.688 10.16 cm x 11.908 cm double gang backbox 4 x 10.16 cm square backbox Includes an LED for annunciation Field programmable Provides priority Monitors dry contact PID 95 Technical Specifications Current 0.0005A 0.0008A Current 0.0015A Temperature 32 to 120 0 to 49 Humidity 93 non condensing 4 x 4.688 10.16 cm x 11.908 cm gang backbox Current 0.0005A 0.0008 A Current 0.0015A Temperature 32 to 120 0 to 49 Humidity 93 non condensing 4 10.16 cm square backbox with blank plate SPECIFICATIONS interface devices shall be provided for the and supervision of contact type devices to the Fire Alarm Control Panel The devices monitor a normally open dry contact The interface devices shall communicate to the control panel via the analog addressable circuit The device shall be Gamewell FCI PID 95P or PID PID 95P and PID 95 are designed to comply with the standard STANDARD Standard 864 9th Edition LISTINGS AND APPROVALS listings and approvals apply to the modules in this document In some cases certain or applications may not be listed by certain agencies or listing may be in process Consult factory for the latest listing status Listed S521 Approved Approved 7300 1703 0135 ISO 9001 Certification a complete listing of all approvals and please visit Series is a registered of Honeywell Inc Windows is a trademark of Corporation is a registered trademark Underwriters Laboratories document is not intended be used for installation We try to keep our information up to and accurate We cannot all specific applications anticipate all requirements specifications are subject to without notice of origin U S A Gamewell FCI Clintonville Road CT 06472 1610 B 04 19 Honeywell International Inc

Related Files