Gamewell-FCI Projected Beam Smoke Detector - BEAM 1224
File Preview
Click below to download for free
Click below to download for free
File Data
Name | gamewell-fci-projected-beam-smoke-detector-beam-1224-7561943208.pdf |
---|---|
Type | |
Size | 657.80 KB |
Downloads |
Text Preview
System Sensor 1224 Series Reflected Type Smoke Detector WITH REFLECTOR six user selectable sensitivity levels Listed to UL Standard 268 Offers a single ended reflective design Projects a 16ft to 328 ft 4.9 to 9.10 m detection range Compatible with UL Listed 24 VDC control panels Provides an integral sensitivity test feature Has a digital display no special tools required Contains a user friendly alignment procedure Operates with an integral automatic gain control that for signal deterioration from dust build up Uses a remote test station optional 54 04 E System Sensor BEAM1224 Series 4 wire projected smoke detector is uniquely suited to sense smoke in areas with high ceilings where spot type detectors difficult to install and maintain It is suitable for use with UL Listed fire alarm control panel providing a 15 32 power source single ended reflective design offers a simpler instal than the traditional transmitter and receiver types of detectors is swiftly accomplished via an optical sight and 2 digit signal strength meter integral with the product for operation from F to 131o F the BEAM1224 be installed in garages warehouses and other harsh where the temperature extremes exceed capability of spot type detectors BEAM1224 consists of a combination transmitter unit and a reflector When the smoke enters the between the unit and the reflector it causes a reduc in the signal and when the smoke level reaches the threshold an alarm results unit has four standard sensitivity selections along with Acclimate settings When either of the two Acclimate are selected the detector will automatically adjust sensitivity using the advanced software algorithms to the optimum sensitivity for the specific environment BEAM1224S is equipped with an integral sensitivity feature consisting of a test filter attached to a servo inside the detector optics Using the remote test sta Model RTS451 the motor moves the filter in the path the light beam thereby serving as an accurate test of receiver sensitivity This test feature allows the user to and easily comply with the annual maintenance test requirements of NFPA 72 is a registered trademark of Underwriters Laboratories Inc GAMEWELL FCI are for information only are not intended for installation purposes and are subject to change without notice No responsibility is assumed by Gamewell FCI for their use Rev C page 1 of 2 Clintonville Road Northford CT 06472 1610 USA Tel 203 484 7161 Fax 203 484 7118 www gamewell fci com Honeywell International Inc All rights reserved 1 BEAM1224 with BEAMMK 1 Multi Mount Kit Specifications Voltage to 32 VDC BEAM1224 to 32 VDC BEAM1224S A max 24 VDC A max 24 VDC A max 24 VDC Current Current Current Mode Specifications A max 24 VDC to 131o F 30o to 55o C 93 non condensing H x 7.5 W x 3.3 D mm x 191 mm x 84 mm 16 to 230 7.9 x 9.1 200 x 230 mm over 230 15.7 x 18.1 400 x 600 mm Indicators Red Alarm Yellow Trouble Green Normal flashing Local Test Local Reset Remote test and reset Compatible with RTS451 and RTS151KEY test station 2 RTS 452KEY Specifications Range 16 to 328 Ft 5 to 100 m 6 Levels Level 1 25 Level 2 30 Level 3 40 Level 4 50 Acclimate Level 1 30 50 Acclimate Level 2 40 50 Condition 10 Degrees horizontal vertical 96 or higher alignment mode Improper initial self compensation limit gunsight integral signal indication 2 digit display smooth ceilings 0 60 feet max projected beams and not than one half that spacing a projected beam and a Other spacing may be used on the ceiling height air characteristics and response See NFPA 72 Aid Information Number Detector Detector w sensitivity Test Range for applications with over 230 ft 70m Kit Mount Kit Test Station Test Station w Key lock Rev C page 2 of 2 Clintonville Road Northford CT 06472 1610 USA Tel 203 484 7161 Fax 203 484 7118