Gamewell-FCI RPT-E3 Network Repeater
File Preview
Click below to download for free
Click below to download for free
File Data
Name | gamewell-fci-rpt-e3-network-repeater-2176530948.pdf |
---|---|
Type | |
Size | 652.13 KB |
Downloads |
Text Preview
RPT E3 Repeater RPT E3 is the network communication used with the E3 Series System ARCNET Repeater Module RPT E3 is an component of the E3 Series and S3 fire alarm control panels It allows the remote E3 Series and S3 Series sub to connect to the Broadband from remote locations ILI MB E3 ILI95 E3 Series S3 Series SLP Smart Loop Panel Main RPT E3 is adaptable for an installation in standard E3 Series and S3 Series cabinets the RPT E3 module is mounted on on the top of the right side of the ILI modules and SLP instructions on the installation of the refer to the following documents E3 Series UL Listing Document ANX SR ANX MR UTP ANX MR FO NGA RPT E3 is a standard sub assembly with connections using unshielded copper wire The following fiber optic network connections add on modules are available FML E3 multi mode fiber module FSL E3 single mode fiber module addition you can use the RPT E3 to remotely mounted NGA modules to network LS10080 051GF E S3 Series UL Listing Document RPT E3 UTP Installation Instructions 9000 0580 FML E3 FSL E3 Installation Instructions INFORMATION Network Repeater unshielded Multi mode fiber optic module for one channel Single mode fiber optic module for one channel AND BENEFITS Listed under UL Standard 864 10th Edition Includes add on fiber optic modules that Offers the 625K baud ARCNET Repeater Provides the capability for networked E3 and S3 Series sub assemblies to in Class B or Class X configurations Connects to the network via the standard twisted pair copper wire the network connection through single multi mode fiber optic cables Use the RPT E3 to connect remotely NGA modules to the network TECHNICAL SPECIFICATIONS Voltage 24 VDC FWR Current 0.016 amp Current 0.017 amp Temperature 32 to 120 F 0 to C Humidity 0 to 93 non condensing 90 F 32 C Specifications Wire 16 to 18 AWG twisted pair to 3,000 ft 914.4 m between each node Cable FML E3 only Up to 200 optimized for 62.5 125 microns to 8 dB loss between nodes Cable FSL E3 only Optimized for micrometer cable 1310 nm to 30dB loss between nodes AND HUMIDITY RANGES system meets NFPA requirements for at 0 49 120 and at a humidity 93 2 RH noncondensing 32 2 90 3 However the useful of the system s standby batteries and the components may be adversely by extreme temperature ranges and Therefore it is recommended that this and its peripherals be installed in an with a normal room temperature of 27 80 RPT E3 is designed to comply with the standard Standard UL 864 10th Edition LISTINGS AND APPROVALS and approvals apply to the specified in this document In some certain modules or applications may not listed by certain approval agencies or listing be in process Consult the factory for the listing status Listed S1869 UL 864 10th Edition Approved 3025415 FDNY COA 6077 7165 1703 0125 of Chicago Class 1 Class 2 and High Rise of Denver 9001 Certification Series Velociti Series and are registered of Honeywell Inc is a registered trademark of Laboratories Inc document is not intended to be for installation purposes We to keep our product information and accurate We cannot all specific applications or all requirements All are subject to change notice of origin U S A Gamewell FCI Clintonville Road CT 06472 1610 P 06 20 Honeywell International Inc