Gamewell-FCI S3 Series, SLC-PM SLC95-PM Personality Modules
File Preview
Click below to download for free
Click below to download for free
File Data
Name | gamewell-fci-s3-series-slc-pm-slc95-pm-personality-modules-8014273695.pdf |
---|---|
Type | |
Size | 673.96 KB |
Downloads |
Text Preview
SLC PM System Sensor Apollo and Networking Systems Personality Loop Modules Gamewell FCI S3 Series Small Addressable Fire Alarm Control Panel signaling circuits SLCs provide the communication between the S3 Series fire alarm panel and the SLC devices Each SLP E3 Smart Loop Panel main board either one or two of the following plug in SLC Personality Modules SLC PM Signaling Line Circuit Personality Module SLC95 PM Signaling Line Circuit 95 Personality Module SLC PM SLC95 PM modules provide one SLC loop in Class B or Class A wiring SLC PM supports the following devices Up to 318 System Sensor Velociti devices 159 sensors and 159 modules Up to 198 System Sensor CLIP devices 99 sensors and 99 modules SLC95 PM supports the following devices Up to 126 Apollo XP95 devices 126 sensors and modules SLC PM SLC95 PM modules are designed to be plugged into the Smart Loop Board SLP E3 This feature allows you to expand the S3 Series Small Fire Alarm Control System without the need to remove or replace Information System Sensor Signaling Line Circuit Personality Module with up to 318 Apollo SLC Personality Module with up to 126 devices BENEFITS Listed per ANSI UL 864 9th SLC PM supports the Sensor Velociti using up to devices Uses up to 159 sensors and 159 modules SLC95 PM supports the Supports Class A or XP95 protocol up to 126 devices Uses up to 126 and modules B Wiring Offers a simple plug in feature Technical Specifications amp 0.016 amp amp Ohms uf max VDC FWR Current Current Impedance Capacitance Voltage Temperature 32 to 120 F 0 to 49 C Humidity amp to 93 non condensing at F 32 C AND HUMIDITY RANGES system meets NFPA requirements for operation at 0 49 120 and at a relative humidity 93 2 non condensing at 32 2 90 3 the useful life of the system s standby batteries the electronic components may be adversely affected extreme temperature ranges and humidity Therefore it recommended that this system and its peripherals be in an environment with a normal room of 15 27 80 SLC PM SLC95 PM are designed to comply the following standard Standard UL 864 9th Edition LISTINGS AND APPROVALS listings and approvals apply to the modules in this document In some cases certain or applications may not be listed by certain agencies or listing may be in process Consult factory for the latest listing status Listed S1869 Approved FDNY COA 6162 7165 1703 0176 of Chicago Approved Class 1 Certificate of Compliance VMA 45894 02C 9001 Certification a complete listing of all approvals and please visit and Gamewell FCI registered trademarks of International Inc is a registered trademark Underwriters Laboratories document is not intended be used for installation We try to keep our information up to and accurate We cannot all specific applications anticipate all requirements specifications are subject to without notice more information more about Gamewell FCI SLC PM SLC95 PM and products available by visiting www Gamewell FCI com Gamewell FCI Clintonville Road CT 06472 1610 E 09 17 Honeywell International Inc