9020 60773 A S3 Series Spec Stand Alone Fire Systems Clintonville Road Connecticut 06472 1653 484 7161 484 7118 2013 Guide Specification Notes This product guide specification is written according to the Construction Specifications CSI 3 Part Format as described in The Project Resource Manual Manual of Practice section must be carefully reviewed and edited by the Architect or Engineer to meet the of the project and local building code Coordinate this section with other specification and the Drawings Delete all Notes when editing this section numbers and titles are from MasterFormat 1995 Edition with numbers and titles from 2004 Edition in parentheses Delete version not required 13850 28 31 00 ALARM SYSTEM Notes This section covers Gamewell FCI S3 Series Small Addressable Fire Alarm System Gamewell FCI for assistance in editing this section for the specific application 1 INCLUDES Small addressable fire alarm system SECTIONS Section 13800 Building Automation and Control Section 13900 21 00 00 Fire Suppression Series Fire Alarm System 28 31 00 1 Notes Edit the following list of related sections as required for the project List other sections work directly related to this section S3 Series Spec Stand Alone Section 27 15 00 Communications Horizontal Cabling Notes List standards referenced in this section complete with designations and titles This does not require compliance with standards but is merely a listing of those used Electrical Industries Association EIA Interface Between Data Terminal Equipment and Data Circuit Terminating Employing Serial Binary Data Interchange Electrical Characteristics of Generators and Receivers for Use in Balanced Systems National Fire Protection Association NFPA NFPA 12 Standard on Carbon Dioxide Extinguishing Systems NFPA 13 Installation of Sprinkler Systems NFPA 15 Standard for Water Spray Fixed Systems for Fire Protection NFPA 16 Standard for the Installation of Foam Water Sprinkler and Foam Water Spray NFPA 16A Standard for the Installation of Closed Head Foam Water Sprinkler Systems NFPA 70 National Electrical Code NEC NFPA 72 National Fire Alarm Code NFPA 90A Standard for the Installation of Air Conditioning and Ventilating Systems NFPA 101 Life Safety Code NFPA 750 Standard on Water Mist Fire Protection Systems NFPA 5000 Building Construction and Safety Code Fire Alarm Control Panel Equipment System shall comply with applicable provisions of the UL standards and classifications UL 864 9th Edition UOJZ Control Units System UOXX Control Unit Accessories System Control Units Releasing Device DESCRIPTION A new intelligent reporting microprocessor controlled fire detection and notification system shall installed in accordance with the specifications and as indicated on the Drawings Each Signaling Line Circuit SLC and Notification Appliance Circuit NAC Limited to only 80 of its total capacity during initial installation C Control Panel shall be expandable from 1 to 2 SLC loops as necessary to accommodate expansion using add on modules Basic Performance Line Circuits SLC Serving Addressable Devices Wired Style 6 Class A Device Circuits IDC Serving Non addressable Devices Connected to Monitor Modules Wired Class A NFPA Style D Series Fire Alarm System 28 31 00 2 S3 Series Spec Stand Alone Notification Appliance Circuits NAC Serving Strobes and Horns Wired Class A NFPA Z On Style 6 or 7 Class A Configurations Single ground fault or open circuit on Signaling Circuit shall not cause system malfunction loss of operating power or ability to report Signals Arriving at Control Panel Not lost following primary power failure until signal is processed and recorded Network Node Communications System shall have the capability of networking with other Control Panels on single of copper wires or fiber optic cables Line Circuits SLC SLC modules shall operate in peer to peer fashion with all SLC modules in the Panel On loss of an SLC module each remaining panel shall continue to communicate with of system including all SLC and control functions NAC Circuits Arranged such that there is a minimum of 1 audible device per fire alarm Notification Appliance Circuits NAC and Control Equipment Arranged such that loss of 1 NAC circuit will not cause loss of any other NAC circuit in system NAC Circuits Electrically supervised for open and short circuit conditions short circuit exists on NAC circuit it shall not be possible to activate that circuit Basic System Functional Operation When fire alarm condition is detected and reported by one the system alarm initiating devices the following functions shall immediately occur Alarm LEDs Flash Piezo Electric Signal in Control Panel Sound at a pulse rate inch Color Touchscreen Display Indicate all information associated with fire alarm including type of alarm point and its location within protected premises Historical Log Record information associated with fire alarm control panel condition with time and date of occurrence History Log shall have a capacity for recording up 4,100 events output programs assigned via control by event equations to be activated by point in alarm shall be executed and the associated system outputs alarm appliances and or relays shall be activated Close Fire Doors Shot down air handlers as required by code Notify the Central Station or Municipal Tie Strobes flash synchronized continuously until system is reset devices sound continuous Temporal pattern until system is reset or silenced Alarm System Functionality complete electrically supervised distributed Style 7 networked fire alarm and control system with analog addressable initiating Alarm System S3 Series multiprocessor based control panel SLP motherboard with 4.3 color touchscreen annunciator SLP and up to 2 loop modules SLC PM or Series Fire Alarm System 28 31 00 3 S3 Series Spec Stand Alone SLC PM SLC module Incorporate 1 Signaling Line Circuits SLC with capacity to up to 159 analog addressable detectors and 159 addressable modules per SLC SLC95 PM SLC module Incorporate 1 Signaling Line Circuits SLC with capacity support up to 126 analog addressable detectors and addressable modules per SLC Control Panel shall incorporate Boolean control by event programming including as a AND OR NOT XOR and Timer functions Control Panel shall have the capability to accept firmware upgrades via connection with computer without requirement of replacing microchips Control Panel shall have the capability of having an optional DACT digital alarm transmitter that can report to single central station monitoring account Control Panel shall have the capability of storing its entire program and allow installer to only devices that are installed during construction without further downloading of Protection Each system shall be provided with 4 levels of password protection up to 16 passwords using 6 digits Control panel shall have an Ethernet port RJ 45 located on the main control board which can be used for uploading and downloading programs from a laptop or desktop computer The Ethernet port can also be used for interface to a Graphic Control System when such a system is specified Notes Edit the Submittals article as required for the project Comply with Section 01330 01 33 00 Submittal Procedures sufficient information clearly presented to determine compliance with the specifications the Drawings Equipment Submittals Cover Page Indicate the following Project name and address Engineered systems distributor name and ot