Gamewell-FCI SM and DSM Sync Modules
File Preview
Click below to download for free
Click below to download for free
File Data
Name | gamewell-fci-sm-and-dsm-sync-modules-7153824690.pdf |
---|---|
Type | |
Size | 596.40 KB |
Downloads |
Text Preview
Description SM and DSM Sync Modules are utilized with the AS AH NS NS4 NH Series RSS RSSP Series SL SLM and selected strobe applications with other and Wheelock combination appliances When with AS Series Audible Strobes and or NS Series Horn the SM and DSM Sync Modules provide independent of synchronized temporal pattern code 3 horn and strobe flash as well as the ability to silence the while maintaining the strobe flash while using only a pair of wires The sync modules are available in two the SM 12 24 for control of a Class B NAC circuit a dual output version the DSM 12 24 for control of either Class A or two 2 Class B NAC circuits DSMs 20 max can be used to synchronize up to 20 A or 40 Class B NAC circuits can also be accomplished using the FireForce 8 power supply UL 1971 Listed York City MEA State Fire Marshal CSFM BFP Approved The SM and DSM Sync Modules can also be used to synchronize Series RSS RSSP SL and SLM Sync Strobes 3 Amp per circuit current handling at 12 or 24 VDC Low operating current draw Compatible with all standard fire alarm control panels Meets the NFPA 72 1999 requirement for Temporal Pattern when used with the Series AS AH and or Series NS NS4 NH Mounts to a 4 11 16 box Rev 1101 6 1 sync modules shall be Series SM or DSM Sync Modules Series SM or DSM Sync Modules shall be the master controllers Series AS AH NS NS4 NH RSS RSSP SL SLM appliances where a synchronized audible visual audible or visual only is specified All modules shall be UL listed under Standard 464 Series SM and DSM modules shall be designed interface with Series AS Audible Strobe Appliances and NS Horn Strobe Appliances to produce a synchronized temporal 3 horn as well as synchronized strobe flash on a two wire alarm circuit Other synchronized products are the Series RSSP SL SLM visual only appliances and Series AH and NH Horn Appliances Sync Module shall incorporate two input NAC circuits for power connection from the Fire Alarm Control Panel one for the NAC circuit and one for the audible NAC circuit DSM modules shall provide an additional strobe circuit input output for of either two Class circuits or a single Class circuit Upon activation of the audible silence function at Fire Alarm Control Panel the audible signal component of Series AS Audible Strobe and or the Series NS Horn Stobe may silenced while maintaining strobe activation SM or DSM module shall be designed and available in two versions the SM 12 24 for control of a single Class B NAC and a dual output version the DSM 12 24 for control of either one Class A or two 2 Class B NAC circuits The DSM dual version shall provide the additional capability of that is the ability to interconnect multiple DSM for horn and strobe operation on multiple NAC circuits Interconnection capability shall be for a maximum of 40 NAC Specifications Number Draw Information Number Module Single Circuit Class B SM 12 24 R Module Single Circuit Class A or multiple Circuit B DSM 12 24 R and wiring information are provided for information only and are believed to be accurate Gamewell assumes no responsi for their use Data and design are subject to change without notice Installation and wiring instructions shipped with the product always be used for actual installation For more information contact Gamewell Gamewell Company Pleasant St MA 01721 in the USA 508 231 1400 888 347 3269 508 231 0900 2001 Rev 1101 6 2