SNAC 4 NOTIFICATION CIRCUIT PANEL Technology Power Supply UL Listed as a Fire Alarm Accessory for Use any FCI or other UL Listed Fire Control 4 Class A Style Z or Class B Y Notification Appliance Circuits High Current Output 1.75 Amp Compact Construction Installation Ground Fault Detection Trouble Contacts N O N C with Optional Delayed AC Failure Compatible With any Listed 24 VDC Appliances Supplementary Notification Appliance Circuit Panel provides four 4 24 VDC Class A Style Z or B Style Y notification appliance circuits with a total of 6 amperes These circuits may be activated in of two or four by connection to normally open dry or existing Class A or Class B notification appliance with operating voltages ranging from 12 to 32 VDC panel may be used to replace earlier versions of the family Either non coded operation coded operation pattern or a combination is possible SNAC 4 operates from 120 240 VAC input and con its own battery charger capable of maintaining a set of 7 batteries It is supervised for ground fault overcurrent circuits and low battery conditions regulated power supply allows the SNAC 4 to be com with any Listed nominal 24 VDC notification appli fault battery and circuit trouble conditions in the automatically open the notification appliance cir used to activate the SNAC 4 transmitting a trouble sig to the main fire alarm control panel The ground fault circuit may be disabled unit contains a set of dry jumper programmable N O N C trouble actuated contacts rated 1 amp 24 VDC Transfer of these contacts for AC power failure is for a period of ten 10 hours This delay feature may disabled power limited non resettable auxiliary power output of amps is available if the panel is arranged via jumper to itself from the batteries during AC power failure output of 0.150 amp is available when the SNAC 4 is to a control panel requiring 24 hr standby The is reduced to 050 amp when 60 hour standby is re Mutual 239 98 E AND ORDERING INFORMATION power battery circuit current current output temperature humidity Number VAC 3 amp or 240 VAC 2 amp 50 60 Hz Jumper selectable VDC nominal 7 ampere hours max amp to 0.235 amp amp excluding notification appliances amp max 24 VDC H x 14 W x 3 1 2 D 35.56 x 35.56 x 8.89 cm to 120o F 0o to 49o C non condensing are provided for information only are not intended to be used for installation purposes and are believed to be accurate However no responsibility is assumed Fire Control Instruments Inc for their use Specifications subject to change without notice All Rights Reserved Southwest Park Westwood MA 02090 USA TEL 781 471 3000 FAX 781 471 3099 ISO 9001 Certified Company 1.5