Gamewell-FCI SWIFT™ Intelligent Wireless Detectors

File Preview
File Preview
Click below to download for free

File Data

Name gamewell-fci-swift-intelligent-wireless-detectors-6270391845.pdf
Type PDF
Size 672.76 KB
Downloads

Text Preview

Intelligent Wireless WSD ACCLIMATE WTD RH WTD H Wireless Detectors wireless detectors are intelligent addressable detectors which provide reliable communication to the Fire Alarm Control Panel FACP across a Class mesh network Wireless detectors create an opportunity for applications where it is concrete walls ceilings buried wires obtrusive surface mount conduit or dangerous asbestos to use traditional wired devices In addition both wired wireless devices can be present on the same FACP providing an integrated wired solution for increased installation potential SWIFT detection line includes a photoelectric Acclimate standard fixed heat rate of rise heat detectors The photoelectric detectors transmit a digital of smoke density through a wireless mesh to a gateway and on to a The Acclimate detectors combine a photoelectric chamber and a 135 fixed heat detector Acclimate can also transmit an alarm signal due to heat UL 521 The fixed heat detector and rate of rise detectors utilize sensors for open area protection with 50 foot spacing capability as approved by UL sensors offer addressable code wheels and two LEDs The LEDs are controlled by panels Operation modes include red green and amber colors with various solid blink patterns mesh network within the SWIFT system creates a child parent relationship the devices so that each device has two parents providing a second path for on every device If one device can no longer operate for any reason rest of the devices can still communicate with each other directly or through one more intermediate devices SWIFT system also engages frequency hopping to prevent system interference intentional or accidental devices communicate across the mesh network through a gateway to the FACP FACP views the SWIFT wireless device and another addressable device on the providing similar detection functions and outputs as a wired counterpart In both wired and wireless devices can be present on the same FACP to meet needs of a given application A SWIFT wireless system can use any combination of smoke and heat detectors pullstations and A V bases Wireless Detector in B210W Base BENEFITS Wireless installation Addressable code Commercial Class A mesh network UL 268 listed Frequency hopping Bi directional Control Panels 7075 Series S3 Series E3 Series Components and Ordering Information WSD P Intelligent wireless photo detector Requires one B210W for installation Requires 4 CR 123A batteries included WSD ACCLIMATE Intelligent wireless Acclimate heat and photo using combined heat and smoke sensor information and ability to automatically adjust sensitivity based on ambient in the environment Requires one B210W base for Requires 4 CR 123A batteries included WTD RH Intelligent wireless rate of rise 135 heat detector one B210W base for installation Requires 4 CR 123A included WTD H Intelligent wireless fixed temperature 135 heat Requires one B210W base for installation Requires 4 batteries included VW GATE Wireless SWIFT Gateway 1 SWIFT Gateway is required each wireless mesh and supports up to 48 SWIFT detectors or and one display driver if required Connects to the SLC of a compatible panel using Velociti protocol Power may be by the SLC circuit or via an optional 24VDC input Use of the 24VDC input may be more convenient for service as it allows for powering a gateway without shutting down an SLC loop VW DIS D LCD user interface for use with the VW GATE wireless and an GFANN 80 Remote Annunciator Connects to the via the ANN BUS Both VW DIS D and GFANN 80 are to display trouble and supervisory conditions that are to the VW GATE and its devices One VW DIS D is required each VW GATE in a system using the E3 or S3 control panel GFANN 80 White 80 character LCD annunciator used with the to display wireless specific events not displayed on the WAM MM Wireless monitor module Used to monitor devices with contact actuation Includes a special cover with a built tamper magnet Recommended for installation in a SMB500 box ordered separately rather than a metal backbox for best Requires 4 CR 123A batteries included WAM RC Wireless relay module for use with the VW GATE wireless Includes a special cover with a built in tamper magnet for installation in an SMB500 WH box ordered rather than a metal backbox for best performance 4 CR 123A batteries included WPS DL Wireless addressable pullstation Requires 4 CR 123A included WAV CRL WAV CWL SWIFT Wireless Addressable A V bases 8 CR 123A batteries included Requires a non ceiling System Sensor L series notification device separately W SYNC Wireless sync module Requires 4 CR 123A batteries SMB500 WH Optional surface mount backbox B210W Detector base used for wireless detectors Includes a built magnet so that wireless devices can establish installed and states SWIFT Tools Programming and diagnostic utility Free download www gamewell fci com For installation on a typically laptop running an approved version of Windows See Minimum Requirements for SWIFT Tools Requires the W USB radio dongle for communication with SWIFT Wireless devices W USB Wireless USB radio antenna dongle that plugs into the port of a PC running SWIFT Tools The W USB provides a link with SWIFT Wireless devices W BATCART Wireless battery cartridge 10 pack For use with pullstations and A V bases 2 of 3 9021 60818 F 10 3 2018 WSD ACCLIMATE WTD RH WTD H Specifications OPERATING LISTINGS AND APPROVALS 2.4 inches 61 mm installed in B210W base 6.0 inches 152mm installed in B210W base Weight includes 4 batteries 9.2 oz 261 g in B210W base Temperature Range Photo 32 120 49 Acclimate with Heat 32 100 0 Velocity Acclimate with Heat 0 4,000 fpm 0 20 m Humidity Range 10 93 non Ratings Fixed Temperature Set Point 135 Rate of Rise Detection 15 8.3 Frequency Range 902 928 MHz Type 4 Panasonic CR123A or 4 Duracell 123A Life 2 years Replacement Upon BATTERY LOW or BAT LOW and or during annual maintenance device complies with part 15 of the FCC rules operation is subject to two conditions The device may not cause harmful interference and 2 device must accept any interference received interference that may cause undesired listings and approvals below apply to the basic wireless detectors In some cases certain may not be listed by certain approval agencies or may be in process Consult factory for latest listing Listed S1913 S2332 7254 1703 0178 7272 1703 0179 Approved ID AUBWFSSD AND CODES SWIFT Wireless Intelligent Detectors comply with the UL Standards and with NFPA 72 Fire Alarm requirements 864 268 Plus E3 Series SWIFT Sensor and Velociti registered trademarks of International Inc and Windows are trademarks of Corporation is a registered of Duracell U S Inc Panasonic is registered trademark of Corporation by Honeywell Inc All rights Unauthorized use of document is strictly document is not intended be used for installation We try to keep our information up to and accurate We cannot all specific applications anticipate all requirements specifications are subject to without notice of origin Mexico Gamewell FCI Clintonville Road CT 06472 1610 F 10 18 Honeywell International Inc

Related Files