Velociti Series Environment Analog Addressable Smoke Sensor Suited for harsh environments High performance filter removes particulate of 25 Compatible with most Gamewell FCI analog address series fire control panels Bicolor LEDs flash green whenever the sensor is and light steady red on alarm Only the red LED is operative in panels that do not operate Velociti mode Information Analog PE Smoke Sensor for Harsh Sensor Base Flanged filters caps for detector ISO 9001 2000 Company Vol VI Gamewell FCI Velociti Series ASD FILTREX F pho analog addressable smoke sensor provides warning smoke sensing in harsh environments traditional smoke sensors are impractical ASD FILTREX F sensor combines traditional smoke sensing technology with a unique smoke system A small intake fan draws air and smoke the sensing chamber where a filter removes airborne and water mist from the air Two 2 high filters remove particulate as small as 25 microns filter can be removed for field cleaning while the sec filter is permanent and provides sensor protection dur cleaning The fan cycles on and off in a 15 duty cycle increase service life and reduce current consumption air delivery system is fully supervised with internal to detect a clogged filter fan failure loss of power communications If a filter clogs the user is alerted to the unit Power up is automatic when the unit is feature allows the sensor to sense smoke while unaffected by dust dirt or occasional water encountered in hostile environments which would create nuisance alarms or dirty in regular analog sensors The rugged con makes the sensor resistant to water spray where hosing down cleaning is performed Velociti Series use a communication protocol that speed of communication the sensors and certain Gamewell FCI analog fire alarm controls These devices operate in grouped fashion If one of the devices in the group has a change the panel microprocessor stops the group and concentrates on the single device The net effect response speed up to five times greater than earlier and E3 Series are registered trademarks of Honeywell International Inc are for information only are not intended for installation purposes and are subject to change without notice No responsibility is assumed by Gamewell FCI for their use Clintonville Road Northford CT 06472 1610 USA Tel 203 484 7161 Fax 203 484 7118 by Honeywell International Inc All rights reserved Rev D page 1 of 2 Continued providing a solution for many hostile environments ASD FILTREX F is not considered applicable for use corrosive hazardous or explosive areas or conditions the ambient conditions specified in the table is tested via a magnet placed against the hous per the Installation Instructions Voltage Current Current SLC Auxiliary Humidity 32 VDC A A A standby A checking for smoke A when checking for airflow to 120 F 0 to 49 C to 93 non condensing 1 2 H x 4 W x 1 1 4 x 10.1 x 3.2 cm Rev D page 2 of 2 Clintonville Road Northford CT 06472 1610 USA Tel 203 484 7161 Fax 203 484 7118

Related Files