Gamewell-FCI Velociti® Series ASD-PL2F, ASD-PTL2F and ASD-PL2FR

File Preview
File Preview
Click below to download for free

Text Preview

Addressable Devices Series ASD PL2F ASD PTL2F and ASD PL2FR Addressable Photoelectronic Smoke Sensor Gamewell FCI Velociti Series analog addressable plug in smoke sensors with communication provide features that surpass conventional sensors can be programmed in the control panel software and is continuously and reported to the panel Point ID capability allows each sensor address be set providing exact locations for selective maintenance when the chamber reaches an unacceptable level ASD PL2F photoelectric sensor unique optical sensing chamber is engineered sense smoke produced by a wide range of combustion sources Dual electronic add 135 57 fixed temperature thermal sensing on the ASD PTL2F Velociti Series use a communication protocol that substantially increases the of communication between the sensors and certain Gamewell FCI analog fire alarm controls These devices operate in a grouped fashion If one of devices in the group has a status change the panel microprocessor stops the poll and concentrates on the single device The net effect is a response speed to five times greater than earlier designs ASD PL2F plug in sensors use a separate base to simplify installation service maintenance A special tool allows maintenance personnel to plug in and remove without using a ladder the base on a box which is at least 1.5 3.8 cm deep Suitable mounting base include 4.0 10.2 cm square box 3.5 8.9 cm or 4.0 10.2 cm octagonal box Single gang box except relay or isolator bases B200S or B200SR base mounted on a 4.0 10.2 cm octagonal or square box B224RB or B224BI base mounted on a 3.5 8.9 cm octagonal box or a 4.0 10.2 cm octagonal or square box Because of the inherent supervision provided by the SLC end of line resistors are not required Wiring or branches are for Style 4 Class wiring Spacing recommends that the spacing sensors be used in compliance with NFPA 72 BENEFITS Offers a sleek low Displays bi color LEDs Includes an optional Designed with an Compatible with green whenever sensor is and light red on alarm Supports a low standby isolator or bases addressable analog panels Contains an optional single gang Indicator Provides a stable with noise Only the red LED operative in panels that not operate in mode design Includes visual rotary switch 01 159 Has a built in test switch by an magnet Information and Options Plug in sensor base without flange 4.1 10.4 cm diameter Flanged mounting base 6.1 15.5 cm diameter Flanged mounting base bulk pack 6.1 15.5 cm diameter Relay Base Plug in sensor base with auxiliary SPDT rated 2 amps 30 VDC resistive terminals Up to 14 AWG 2.0 mm2 coil latching relay 1 Form C contact UL CSA Rating A 125 VAC inductive A 110 VDC inductive A 30 VDC resistive 6.1 15.5 cm diameter 25 devices between isolator bases Intelligent sensor sounder base 6.875 17.5 cm diameter Standard sounder base UL 8649th Edition ULC Listed 6.875 17.5 cm diameter Remote LED Annunciator Black detector covers box of 10 Duct smoke housing Series ASD PL2F ASD PTL2F and ASD PL2FR Technical Velociti Series ASD PL2F PTL2F PLSFR are to comply with the following standard Standard 864 9th Edition Listings and Approvals listings and approvals apply to the modules in this document In some cases certain or applications may not be listed by certain agencies or listing may be in process factory for latest listing status S1913 3023594 FDNY COA 219 02 E Vol VI 7272 1703 0121 9001 Certification a complete listing of all approvals and please visit Series Velociti and are registered of Honeywell Inc is a registered trademark Underwriter Laboratories document is not intended be used for installation We try to keep our information up to and accurate We cannot all specific applications anticipate all requirements specifications are subject to without notice ASD PTL2F ASD PL2FR 2.1 5.1 cm height 4.1 10.4 cm installed in the B501 base 6.1 15.5 cm installed in the B210LP base Weight 5.2 oz 147 g Temperature 32 F to 120 F 0 C to 49 C 32 F to 100 F 0 C to 38 C Velocity Range 0 4000 ft min 1,219.2 m suitable for installation in ducts Humidity 10 93 non condensing Ratings Fixed temperature setpoint 135 F C Specifications Range 15 32 volts DC peak Current max avg 0003 A 24 VDC communication every 5 seconds with LED blink Alarm Current 0065 A 24 VDC LED lit AND HUMIDITY RANGES system meets NFPA requirements for operation at 0 49 120 and at a relative humidity 93 2 noncondensing at 32 2 90 3 the useful life of the system standby batteries the electronic components may be adversely affected extreme temperature ranges and humidity Therefore is recommended that this system and its peripherals be in an environment with a normal room of 15 27 80 more information more about Gamewell FCI Velociti Series ASD PL2F and ASD PL2FR and other products available by www Gamewell FCI com Gamewell FCI Clintonville Road CT 06472 1610 K 11 17 Honeywell International Inc

Related Files