Gamewell-FCI VESDA Display Modules
File Preview
Click below to download for free
Click below to download for free
File Data
Name | gamewell-fci-vesda-display-modules-5026143879.pdf |
---|---|
Type | |
Size | 1.27 MB |
Downloads |
Text Preview
Display Modules modules provide real time indication of the status of a VESDA detector They a 20 segment vertical bar graph display a 2 digit numeric display an audible clear alarm and fault indicators They also have push button keys to control the detector and the mode of the display Display Module can be mounted into a detector unit a remote mounting box or a sub rack Several displays can be con gured to display information from a single in multiple locations are various versions of the display module depending on the type of detector and relay con guration required The LaserSCANNER display has a fourth mode for the Display which shows the First Alarm Sector FAS this being the number of sector pipe that has detected smoke For the LaserCOMPACT the Fire 2 LED is Indication levels are continuously shown on a bar graph display where each illuminated indicates the current level of detected smoke top segment of the bar graph indicates the Fire 1 smoke threshold level and each below that level represents 1 20 of the Fire 1 smoke threshold level the left of the bar graph are the Fire 1 Action and Alert smoke threshold indicators a glance these provide a visual representation of the programmable alarm showing how close the smoke level is to triggering the next level of alarm Lights intensity ashing LEDs provide a clear indication of the re condition and are by an audible warning appropriate to the alarm condition Similarly fault condition is indicated by a series of LEDs and an audible tone providing a range of status information The audible warning is easily silenced by the Silence button at which point any ashing LEDs are illuminated until the of the event is identi ed recti ed and the system reset Display 2 digit numerical readout has a number of that are indicated by up to four LEDs The current smoke level in obscuration ft obscuration m Fire 1 threshold in obscuration ft obscuration m This is the sensitivity of detector The VESDA zone number First Alarm Sector on the LaserSCANNER the numeric readout shows the pipe number that has detected Button Keys large tactile push button keys enable to reset isolate or silence the detector control the mode of the display module buttons can be disabled to prevent of it functions lamp test routine is initiated by pressing the key for two seconds A Manual Scan be initiated on the LaserSCANNER by the Silence button for 2 seconds Immediate Status Reporting a Single VESDA Zone Zone Control of Assigned Detector Intensity Alarm LEDs Relay Option Vertical Bar Graph Display Threshold Indicators Sounder for Audible Warning Fault Reporting Numeric Display defaults smoke obscuration Mounting Option Clintonville Road Northford CT 06472 1610 USA Tel 203 484 7161 Fax 203 484 7118 are for information only are not intended for installation purposes and are subject to change without notice No responsibility is assumed by Gamewell FCI for their use www gamewell fci com GF13803 08 page 1 of 2 Modules Module side view Module front view mm mm Mounting Box DIA KNOCKOUTS TOP 2 BACK 1 EACH SIDE 2 VIEW DIA DIA VIEW VIEW Sub Rack mm VIEW VIEW Americas 1 781 740 2223 Asia 852 2297 2438 Australia and New Zealand 61 3 9936 7000 Europe 41 55 285 99 99 UK and the Middle East 44 1442 242 330 contents of this document are provided on an is basis No representation or warranty either express or implied is made as to the accuracy or reliability of the contents of this document The manufacturer reserves the right to change designs or speci cations obligation and without further notice Except as otherwise provided all warranties express or implied including without limitation any warranties of merchantability and tness for a particular purpose are expressly excluded document includes registered and unregistered trademarks All trademarks displayed are the trademarks of their respective owners use of this document does not constitute or create a licence or any other right to use the name and or trademark and or label document is subject to copyright owned by Xtralis AG You agree not to copy communicate to the public adapt distribute transfer modify or publish any contents of this document without the express prior written consent of Xtralis no 13803 08 17921 cations Voltage 18 to 30 VDC Consumption 24 VDC Only Remote Mounting Box relays With Alarm Quiescent With Alarm W mA W mA W mA W mA WHD Mounted in Remote Box in x 5.9 in x 3.4 in 140 mm x 150 mm x 85 mm Temperature 32 to 103 0 to 39 10 99 RH non condensing Indicators High Intensity LEDs with 70 degree angle Buttons Keys Silence Scan Reset Isolate be disabled during commissioning except Silence pressed key gives a short tone when enabled and a long when disabled Dual Function press Selects modes on the numeric display Smoke Level and Zone Number LaserSCANNER displays the First sector pipe in alarm be selected Note The current mode is indicated the appropriate LEDs press Activates the Test Mode Silence Scan function on SCANNER only press Silences any alarm or fault warnings LEDs are permanently lit until the event is cleared the system reset Only affects the local display press Initiates the scanning of each pipe individually smoke and displays the current levels Resets all the alarms and faults on the detector and associated displays If the alarm or fault condition has been cleared then the appropriate fault indications will repeated Reset does not clear the isolate mode Isolates the detector from any external devices systems This includes all the relays in the detector and remote units Isolate relay is activated while the detector in isolate mode Indicators A fault that affects the whole VESDA system devices connected on VESDAnet A fault that affects only the assigned VESDA detector its associated displays A serious fault that requires immediate attention light will only illuminate when at least one other fault is lit A fault with either the mains AC or battery backup supply A failure in the VESDAnet communications link ow Air ow drift Urgent indicates serious aspirator or failure Filter needs replacing Urgent indicates that lter is overdue Information in Remote Mounting Box with termination card Relays Relays Relays Relays Relays Relays Relays Relays Mounting Kit Optional gured in 19in Sub Racks Xtralis page 2 of 2 www gamewell fci com Clintonville Road Northford CT 06472 1610 USA Tel 203 484 7161 Fax 203 484 7118