Gamewell-FCI Wheelock AS AH Selectable Output Strobe & Horns

File Preview
File Preview
Click below to download for free

Text Preview

Cooper Wheelock Series Multi Candela Series Audible Strobe Series Audible Appliances AS Approvals include UL Standard 1971 New York City MEA AH UL Standard 464 California State Fire Marshall CSFM ADA NFPA UFC ANSI compliant Wall mounted models are available with field multi settings of 15 30 75 or 110 cd Ceiling mounted models are available with field select multi candela settings of 15 30 75 or 95 cd Single candela models are available in 15 75 cd Weatherproof models are available for outdoor use Selected continuous horn or temporal pattern 3.41 Three 3 field dBA settings adjusted to 90 95 or 99 for both tones Silenceable horns and non silenceable strobes over the same wires Strobes flash once per second over the regulated volt range 12 24 VDC models with wide UL voltage using filtered DC or unfiltered FWR input voltage Synchronize with SM or DSM synchronization Fast installation with In Out screw terminals using 12 to ISO 9000 2000 Company AWG wires 2 wire Cooper Wheelock AS Series audible and AH Series audible notification appliances many features with low current draws options for wall mounted models include cd or field selectable Multi Candela strobes may be set to 15 30 75 or 110 cd mounted models incorporate field selected settings of 15 30 75 or 95 cd audible notification appliances provide a field choice of either a continuous horn tone or pattern per ANSI S3.41 when constant is supplied by the notification appliance cir Each tone has three dBA settings to choose Additionally the audible tone may be silenced maintaining strobe activation models may be synchronized when the models used in conjunction with the Cooper Wheelock and DSM Sync Modules synchronization of the continuous horn tone the temporal pattern mandated by NFPA for fire evacuation signaling This ensures a distinguishable temporal pattern when two or audible devices are within hearing distance If horn tones are not synchronized the temporal may overlap At the same time the strobes also be synchronized This process is in compli with ADA recommendations regarding photo epilepsy and NFPA and UFC standards when installing two or more visual appli within a common field of view two wires are required to achieve these se of operation Separate circuits for audible visual devices are not necessary are for information only are not intended for installation purposes and are subject to change without notice No responsibility is assumed by Gamewell FCI for their use Clintonville Road Northford CT 06472 Tel 203 484 7161 Fax 203 484 7118 Gamewell FCI All rights reserved Rev C1 page 1 of 4 Continued Notes Strobes are designed to flash at one flash per second over the Regulated Voltage Range Note that 1999 specifies a flash rate of one to two per second and ADA guidelines specify a flash of one to three flashes per second All candela ratings represent minimum effective strobe based on UL Standard 1971 Series AS strobe products are Listed under UL Standard for indoor use with a temperature range of 32 F to F 0 C to 49 C and a maximum humidity of 93 2 Series AH horns are Listed under UL Standard 464 for signal appliances indoor use only Series AH 24WP audible appliances are Listed under UL 464 for indoor outdoor use with a temperature of F to 150 F C to 66 C and a maximum humidity of 95 Voltage Range is the state of the art technol used by UL to identify the voltage range Prior to this UL used the term Voltage Range 1 Ratings per UL 1971 24 24 12 C C WP 2475W FR 24 2 Average RMS Current fir AS 24 MCW Wall each Candela Setting Voltage VDC FW R cd 75 or Axis 75 or Axis 75 95 31 F Current with High dBA Setting 99 dBA cd cd VDC 0.099 VDC 0.093 VDC 0.098 cd cd Current with Medium dBA Setting 95 dBA VDC 0.078 VDC 0.065 VDC 0.065 Current with Low dBA Setting 90dBA VDC 0.070 VDC 0.052 VDC 0.046 3 Average Mean Current Series AH 12 R W W P Horn only VDC VDC VDC VDC VDC VDC VDC VDC VDC 4 Avereage RM Current Series AS0241575 5 dBA Ratings for 12 VDC 24 VDC Series 12 24 VDC Horns dBA UL 464 pt pt 6 Average RM S Current for AS 24 M CC Ceil Models each Candela Setting Current with High dBA Setting 99 dBA cd cd cd VDC VDC VDC VDC VDC VDC cd Current with Medium dBA Setting 95 dBA Current with Low dBA Setting 90 dBA VDC VDC VDC 7 Average Mean Current Series AS 241575 Low VDC VDC VDC Clintonville Road Northford CT 06472 Tel 203 484 7161 Fax 203 484 7118 Rev C1 page 2 of 4 MODULES VDC MEAN 24VDC SM Sync Module is rated for 3.0 amps 24 VDC DSM Sync Module is rated for 3.0 amps per circuit maximum number of interconnected Modules is 20 DIAGRAMS AS APPLIANCES NON SYNCHRONIZED APPLIANCE FACP NEXT APPLIANCE EOLR AS APPLIANCES SYNCHRONIZED SM MODULE SINGLE CLASS B NAC WITH AUDIBLE SILENCE FEATURE STROBE STROBE AUDIBLE AUDIBLE AS APPLIANCES SYNCHRONIZED DSM MODULE SINGLE CLASS A NAC WITH NO AUDIBLE SILENCE FEATURE AS APPLIANCES SYNCHRONIZED MUTIPLE DSM MODULES SYNC SYNC OUT 1 IN 1 1 2 IN 2 OUT 2 AUDIBLE AUDIBLE 1 SYNC SYNC 2 SYNC SYNC 3 SYNC SYNC INTERCONNECTING WIRING SHOWN OF TWENTY 20 MODULES Clintonville Road Northford CT 06472 Tel 203 484 7161 Fax 203 484 7118 Rev C1 page 3 of 4 and Engineers Specifications notification appliances shall be Cooper Wheelock Series AS audible strobe appliances and Series AH audible appliances or

Related Files