Gamewell-FCI Wheelock CH Series Chimes Strobes
File Preview
Click below to download for free
Click below to download for free
File Data
Name | gamewell-fci-wheelock-ch-series-chimes-strobes-2036581749.pdf |
---|---|
Type | |
Size | 870.40 KB |
Downloads |
Text Preview
Cooper Wheelock Series Chimes and Chime Strobes Strobe Strobes meet or exceed latest NFPA ANSI Standards ADA Accessibility Guidelines Meets OSHA 29 Part Unique electronic chime design provides superior qual versatile performance and improved appearance one tenth the current draw of most electromechani chimes Field selectable choice of single stroke or vibrating op with volume and tone control CH70 strobe models available with single 15 75 and 15 30 75 110 and 135 185 candela ratings for operation from a single NAC cir in vibrating mode or separate NAC circuits CH90 strobe models available with multiple 15 30 75 95 115 177 candela ceiling mounting Low current draw reduced non sync sync models are for wall mounting only Synchroniza requires SM or DSM sync modules and PS 12 24 or PS 12 24 8MP power supplies 24 VDC chime and chime strobe models with wide voltage range using filtered DC or unfiltered Polarized inputs for compatibility with standard super circuit wiring Low cost installation on standard electrical boxes At flush or surface mounting options The 15 75 candela wall mounted strobes are listed at candela under UL Standard 1971 and meet 75 can intensity on axis for ADA guidelines with low cur draw ISO 9000 2000 Company Cooper Wheelock CH Series Electronic Chimes mini alarm system power supply and wiring costs with a current draw of just 22 mA These unique solid state signals provide field selectable single stroke or operation with sound level adjustable up to 83 dBA and tone adjustable from 800 to 1200 Hz They available in two attractive package styles for flush on standard electrical boxes or convenient sur mounting chimes incorporate a new patent pending mounting for faster easier level installation with a new two 2 grill cover for an aesthetically pleasing appearance they incorporate the new lower current re inrush Series RSS Non Sync Sync Strobes of the strobe flash is achieved when with the Cooper Wheelock SM or DSM sync mod Chime Strobes are designed for maximum perform reliability and cost effectiveness while meeting or the latest visible signaling requirements of 72 ANSI 117.1 the American National Standard of and Usable Buildings and Facilities and UL 1971 CH Chime Strobes when properly speci and installed in accordance with NFPA ANSI Stan can provide the equivalent facilitation allowed un ADA Accessibility Guidelines ADAAG General Sec 2.2 by meeting or exceeding the illumination which from the ADA specified strobe intensity of 75 can at 50 feet 15.24 m This is an illumination of 0.030 per square foot footcandles CH Series Chime Strobes are UL Listed for indoor ceiling and wall mounted under Standard UL 1971 Emergency Devices for the Hearing Impaired and un Standard UL 464 for Private Mode Audible Signal They incorpo rate a Xenon flashtube with state circuitry enclosed in a rugged LEXAN lens to maximum reliability for effective visible signaling Series Chimes are offered in 24 VDC models and are to operate over a wide voltage range with fil DC or unfiltered input voltage All models include IN wiring terminations that accept two 12 AWG 3.25 to 18 AWG 0.75 mm wires at each terminal In are polarized for compatibility with standard reverse type supervision is a registered trademark of GE Plastics a subsidiary of General Company are for information only are not intended for installation purposes and are subject to change without notice No responsibility is assumed by Gamewell FCI for their use Clintonville Road Northford CT 06472 Tel 203 484 7161 Fax 203 484 7118 Gamewell FCI All rights reserved Rev B1 page 1 of 4 Notes Strobes are designed to flash at 1 flash per second from 20 to 31 VDC Note that ADA guide specify a flash rate of 1 to 3 flashes per second NFPA 72 1996 specify a flash rate of 1 to 2 per second CH Series Strobes are UL 1971Listed for indoor use with temperature range of 32 to 120 0 to 49 and humidity of 85 RH CH Series Chimes are Listed under UL 464 for audible appliances All candela ratings represent minimum effective strobe based on UL 1971 and Ordering Information 24 VDC STROBE CHIMES NUMBER 15 75 ON AXIS 24 24 dBA 10 FEET m m 10 FT AVG 24 VDC 140 140 270 270 159 159 CURRENT 0.028 0.035 O P Q R U Y O P Q R U Y O P Q R U Y O P Q R U Y O P Q R U Y O P Q R U Y O P Q R U Y U V U V U V U V SYNC MODULES 1 CH70 is offered in red only CH90 is offered in white only 2 SUFFIXES USED ABOVE 70 square round W Wall mounting F Fire lettering R at end Red W at end White EXAMPLES CH70 2415W FR Wall mounting Fire lettering Red CH90 24 W round White 3 CH BF1 R discontinued 12 30 97 replace CH70 24 R and SBB R backbox Average current per actual Cooper Wheelock Production testing 24 VDC nominal for Chime and Chime combined For rated average peak and inrush currents across the listed voltage ranges for both fil DC and unfiltered VRMS see the installation instructions For descriptions of mounting options refer to Notifier Data Sheet DN 6111 derived from Cooper Wheelock SM Sync Modules are rated for 3.0 amperes at 12 24 VDC DSM Sync Modules are rated for 3.0 amperes circuit The maximum number of interconnected DSM modules is twenty 20 Refer to installation instruc for SM Cooper Wheelock P83123 and DSM Cooper Wheelock P83177 Notes The chimes are factory set in single stroke SS mode They can be changed to vibrating VIB mode with jumper PC board SINGLE STROKE OPERATION The minimum input pulse duration must be at least 160 ms and 160 ms time VIBRATING OPERATION Continuous input voltage applied to the chime will activate chime at one second intervals mode is selected the installer may want to fine tune the signal to better suit the application The volume and tone controls have been adjusted at the factory to ensure maximum dBA output However once ANECHOIC dBA is measured in anechoic chamber with peak meter response REVERBERENT dBA is rated per CHIME INRUSH CURRENT is 0.100 amps maximum 0.140 amps with VRMS input voltage Standard 464 Clintonville Road Northford CT 06472 Tel 203 484 7161 Fax 203 484 7118 Rev B1 page 2 of 4 DIAGRAMS ALL MODELS SYNC OR NON SYNC CHIME AND STROBE OPERTATE CHIME FACP NEXT CHIME EOLR NEXT STROBE EOLR DEVICE MODULE FACP CHIME DEVICES SYNCHRONIZED DSM MODULE SINGLE CLASS A STYLE Z NAC CIRCUIT WITH NO AUDIBLE SILENCE SYNC SYNC OUT 1 IN 1 1 2 IN 2 OUT 2 AUDIBLE AUDIBLE CHIME STROBES CHIME DEVICES SYNCHRONIZED MUTIPLE DSM MODULES 1 SYNC SYNC 2 SYNC SYNC 3 SYNC SYNC INTERCONNECTING WIRING SHOWN OF TWENTY 20 MODULES