Gamewell-FCI Wheelock Exceder Series

File Preview
File Preview
Click below to download for free

File Data

Name gamewell-fci-wheelock-exceder-series-0918247653.pdf
Type PDF
Size 652.82 KB
Downloads

Text Preview

Exceder and Strobes Notification Appliances Front Side Front Side Exceder Series Multiple voltages Voltage test points for quick troubleshooting and easy checking wall models only 3 audible settings 90 95 99 dB 8 Candela settings Wall 15 1575 30 75 95 110 135 185 Ceiling 15 30 60 75 95 115 150 177 Finger slide switches Sleek modern aesthetics Common base for wall and ceiling with 5 mounting 1 gang 2 gang 4 in square 3.5 in octal 4 in octal Wheelock Exceder Series of notification appliances a sleek modern design and numerous advantages eight candela options in one appliance low cur draw no tools needed for setting changes 12 24 VDC universal mounting base and multiple mounting come with an audible feature of 3 sound settings 95 99 dB All switches to change settings can be set the use of a tool and are located behind the appli to prevent tampering Wall models feature voltage test to take readings with a voltage meter for trouble and AHJ inspection Wheelock Exceder Series of wall and ceiling notifi appliances feature a Universal Mounting Base designed to simplify the installation and the testing horns strobes and combination horn strobes The sepa universal mounting base can be pre wired to allow full of circuit wiring before the appliance is installed and surface is finished It comes complete with a Contact for protection against dirt dust paint and damage to contacts The Contact Cover also acts as a shunting to allow pre wire testing for common wiring issues Contact Cover is polarized to prevent it from being incorrectly and prevents the appliance from being while it is on the UMB When the Contact Cover is the circuit will show an open until the appliance is The UMB allows for consistent installation and replacement of appliance Wall models include an locking screw to provide an extra secure installa while the ceiling models provide a captive screw to the screw from falling during the installation and Requirements following list the compatibility and requirements Synchronize using Wheelock Sync Modules or panels built in Wheelock patented sync protocol Compatible with UL Voltage using filtered or unfiltered VRMS input voltage Strobes produce one flash per second over the Voltage range Specifications The Series HS and ST wall models shall have a low pro measuring 5.24 H x 4.58 W x 2.19 D Series HN wall shall measure 5.24 H x 4.58 W x 1.6 The Series HSC and STC shall be round and have a low with a diameter of 6.68 x 2.63 D Series HNC ceiling shall have a diameter of 6.68 x 1.50 D is a registered trademark and Exceder is a trademark of Cooper Wheelock Inc is a registered trademark of GE Plastics a subsidiary of General Electric Corp is a registered trademark of Underwriters Laboratories Inc are for information only are not intended for installation purposes and are subject to change without notice No responsibility is assumed by Gamewell FCI for their use Clintonville Road Northford CT 06472 1610 USA Tel 203 484 7161 Fax 203 484 7118 by Honeywell International Inc All rights reserved Rev A page 1 of 2 Notes All candela ratings represent minimum effective strobe based on UL Standard 1971 Series Exceder Strobe products are Listed under UL 1971 and 464 for indoor use with a tempera range of 32 to 120 0 to 49 and a maxi humidity of 93 2 UL 464 85 UL 1971 Series Exceder horns are under UL Standard 464 for signal appliances Indoor use only Product naming conventions The Exceder line model breakdown into easy to remember codes C Ceiling Mount HN Horn ST Strobe W White R Red HS Horn strobe Refer to your fire alarm panel or power supply man when calculating the number of devices allowed circuit Specifications notification appliances shall be Wheelock Exceder HS Audible Strobe appliances Series ST Visual appliances and Series HN Audible appliances or equals The Series HS and ST Strobes shall be for UL Standard 1971 Emergency Devices for the for Indoor Fire Protection Service The HS and HN Audibles shall be UL Listed under Stan 464 Fire Protective Signaling All Series shall meet requirements of FCC Part 15 Class B All inputs shall compatible with standard reverse polarity supervision of wiring by a Fire Alarm Control Panel FACP with ability to operate from 8 to 33 VDC Indoor wall models voltage test points for easy voltage inspection Series HS Audible Strobe and ST Strobe appliances produce a flash rate of one flash per second over the Voltage Range and shall incorporate a Xenon enclosed in a rugged Lexan lens The Series be of low current design Where Multi Candela appli are specified the strobe intensity shall have 8 field settings at 15 15 75 30 75 95 110 135 185 for wall mount and 15 30 60 75 95 115 150 candela for ceiling mount Specifications Continued selector switch for selecting the candela shall be resistant The 15 75 candela strobe shall be speci when 15 candela UL Standard 1971 Listing with 75 on axis is required e g ADA compliance Appli with candela settings shall show the candela selec in a visible location at all times when installed audible shall have a minimum of three field selectable for dBA levels and shall have a choice of continu or temporal Code 3 audible outputs Options Series HS Audible Strobe ST Strobe and Series HN shall incorporate a patented Universal Mounting that shall allow mounting to a single gang double 4 inch square 3.5 inch octal 4 inch octal or 100mm type back boxes Two wire appliance wiring be capable of directly connecting to the mounting Continuity checking of the entire NAC circuit prior to any notification appliances shall be allowed The shall come with a Contact Cover to protect contact Removal of an appliance shall result in a supervi fault condition by the Fire Alarm Control Panel The mounting base shall be the same base all horn strobe horn strobe wall and ceiling mod All notification appliances shall be backwards compatible synchronization is required the appliance shall be with Wheelock SM DSM Sync Modules Power Supplies or other manufacturer pan with built in Wheelock Patented Sync Protocol The shall not drift out of synchronization at any time operation If the sync protocol fails to operate the shall revert to a non synchronized flash rate and maintain one flash per second over its Regulated Volt Range The appliance shall also be designed so that audible signal may be silenced while maintaining activation when it is used with the Wheelock syn protocol and Ordering Information VDC w SM DSM or PS 8 and Candela Options 15 75 30 75 95 110 135 185 15 75 30 75 95 110 135 185 30 60 75 95 115 150 177 30 60 75 95 115 150 177 Strobes VDC models feature 15 and 15 75 settings Due to the continuous development of Cooper Wheelock products specifications and offerings are subject to change with notice in accordance with Cooper Wheelock Inc dba Cooper Notification standard terms and conditions 15 75 30 75 95 110 135 185 15 75 30 75 95 110 135 185 30 60 75 95 115 150 177 30 60 75 95 115 150 177 Mounting Base Mounting Base Mounting Base Mounting Base Mounting Base Mounting Base Mounting Base Mounting Base Mounting Base Mounting Base Mounting Base Mounting Base Rev A page 2 of 2

Related Files