Gamewell-FCI Wheelock RSS RSSP Selectable Output Strobe Candela Strobes & Strobe Plates
File Preview
Click below to download for free
Click below to download for free
File Data
Name | gamewell-fci-wheelock-rss-rssp-selectable-output-strobe-candela-strobes-strobe-plates-8509726134.pdf |
---|---|
Type | |
Size | 853.67 KB |
Downloads |
Text Preview
Cooper Wheelock Series RSS Strobes and Strobe Plates have low current draw while outstanding performance reliability and effectiveness These versatile appliances will virtually all requirements for indoor wall or mount applications options for wall mount modules include or the MCW multi candela strobe with field settings of 15 30 75 100 cd or the high MCWH strobe with field selectable 135 185 settings Ceiling mount models include the MCC ceiling strobe with field selectable set of 15 30 75 95 cd or the high intensity MCCH with field selectable 115 177 cd settings models may be synchronized with the Cooper SM or DSM Sync Modules Synchronized can eliminate possible restrictions on the of strobes in the field of view Cooper synchronized strobes offer an easy way comply with ADA recommendations concerning epilepsy as well as meeting the re of NFPA 72 Series RSS Strobes employ an Strobe Mounting Plate that can be mounted a single gang double gang 4 square 100 mm backbox or to the SHBB surface back If the flush backbox has side or top space be it and the finished wall the NATP Notification Trimplate may be used It provides an 0.65 of trim for the appliance An attrac cover plate is provided for a clean finished ap on all models Series RSSP Multi candela Strobe Plate is a effective way to retrofit required wall strobe ap to bells horns chimes multitone devices speakers and easily mounts to standard 4 back or for surface mount use with the Cooper SBL2 surface backbox Series Multi Candela Series Strobes Series Strobe Plates Series Series Series Indicator of lens Approvals include UL Standard 1971 California State Fire Marshal New York City MEA Factory Mutual FM ADA NFPA UFC ANSI compliant Wall mounted models are available with field selectable multi candela settings of 15 30 75 or 110 cd with high Ceiling mounted models are available with field select multi candela settings of 15 30 75 or 95 cd with intensity models set to 115 or 177 cd models settable to 135 or 185 cd Single candela models provide 15 75 cd Strobes flash once per second over the regulated voltage range 12 24 VDC models with wide UL volt age using filtered DC or unfiltered FWR input volt age Synchronize with SM or DSM sychronization modules Fast installation with IN OUT screw terminals using 12 18 AWG wires ISO 9000 2000 Company are for information only are not intended for installation purposes and are subject to change without notice No responsibility is assumed by Gamewell FCI for their use Clintonville Road Northford CT 06472 Tel 203 484 7161 Fax 203 484 7118 Gamewell FCI All rights reserved Rev B1 page 1 of 4 Notes Strobes are designed to flash at one flash per second minimum over Regulated Voltage Range Note that NFPA 72 specifies a flash rate of one to two flashes per second and ADA guidelines specify a flash rate of one to three per second All candela ratings represent minimum effective strobe intensity based on UL Standard 1971 Series RSS RSSP Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32 to 120 0 to 49 and maximum humidity of 93 2 Voltage Range is the newest terminology used by UL to identify the voltage range Prior to this UL used the Voltage Range 1 Average RMS Current Wall Mount Ceiling Mount cd cd cd cd cd cd cd Average RMS Current is per UL average RMS method and Average Mean Current is per UL av mean method 12 volt models use Average Mean Current rated inrush and peak current across the UL Listed voltage range for both filtered DC and un Vrms FWR see installation instructions VDC 2 Audible Speakers for Strobe Plate Appliances Bells MT NH HS Modules 24 E70 Sync Module is rated for 3.0 amperes 24 VDC DSM Module is rated for 3.0 amperes per circuit maximum number of interconnected DSM modules is 20 Clintonville Road Northford CT 06472 Tel 203 484 7161 Fax 203 484 7118 Rev B1 page 2 of 4 RSS RSSP APPLIANCES SYNCHRONIZED RSS RSSP APPLIANCES SYNCHRONIZED MUTIPLE DSM MODULES DSM MODULE SINGLE CLASS A NAC CIRCUIT DIAGRAMS RSS RSSP APPLIANCES NON SYNCHRONIZED APPLIANCE MODULE SUPPLY FACP NEXT APPLIANCE EOLR SYNC SYNC OUT 1 IN 1 1 2 IN 2 OUT 2 AUDIBLE AUDIBLE APPLIANCE MODULE SUPPLY FACP RSS RSSP APPLIANCES SYNCHRONIZED SM MODULE SINGLE CLASS B NAC CIRCUIT STROBE STROBE AUDIBLE AUDIBLE 1 SYNC SYNC 2 SYNC SYNC 3 SYNC SYNC INTERCONNECTING WIRING SHOWN OF TWENTY 20 MODULES ASSEMBLY VISIBLE APPLIANCE IN UNISON NEXT APPLIANCE EOLR APPLIANCE FACP APPLIANCE MODULE SUPPLY FACP INDEPENDENTLY ASSEMBLY VISIBLE APPLIANCE NEXT APPLIANCE EOLR NEXT STROBE EOLR Clintonville Road Northford CT 06472 Tel 203 484 7161 Fax 203 484 7118 Rev B1 page 3 of 4 and Engineers Specifications visual notification appliances shall be Cooper Wheelock Series RS strobe appliances or approved equals The RSS shall be Listed under UL Standard 1971 Emergency Devices for the Hearing Impaired for Indoor Fire Service The strobe shall be listed for indoor use and shall meet the requirements of FCC Part 15 Class B strobe appliances shall produce a flash rate of one 1 flash per second over the Regulated Voltage Range and incorporate a Xenon flashtube enclosed in a rugged Lexan lens Series RSS shall be of low current design Where multi candela appliances are specified the strobe intensity have a minimum of four 4 field selectable settings and shall be rated per UL Standard 1971 at 15 30 75 and cd or 135 185 cd for wall mount or 15 30 75 and 95cd or 115 177 cd for ceiling mount The selector switch for the candela shall be tamper resistant The 15 75 candela strobe shall be specified when 15 cd UL Standard Listing with 75 cd on axis is required e g ADA compliance synchronization is required the appliance shall be compatible with Cooper Wheelock SM and DSM Sync The strobes shall not drift out of synchronization at any time during operation If the sync module fails to i e contacts remain closed the strobe shall revert to a non synchronized flas