Gamewell-FCI XAS Air-Sampling Smoke Detection
File Preview
Click below to download for free
Click below to download for free
File Data
Name | gamewell-fci-xas-air-sampling-smoke-detection-2487360159.pdf |
---|---|
Type | |
Size | 679.63 KB |
Downloads |
Text Preview
Xtralis XAS Detectors XAS 2 US Offers single or dual inlet fire detection Has multiple piping options and detection strategies Extends to 164 ft 50 m maximum per unit pipe length to 50 ft 15 m maximum per flexible tube Controlled by a microprocessor Uses a high performance aspirator Built with a field serviceable air filter Provides an adjustable aspirator speed with airflow an integral display and programmer Compatible with the Gamewell FCI ASD PL2F photo Information Number Description Smoke Detector with 1 inlet Smoke Detector with 2 inlets Profile Photo Detector for Gamewell FCI detectors of 10 detectors are ordered from their manufacturer Xtralis XAS Air sampling Smoke Detection System a flexible detection solution to meet unique needs challenging applications found in typical commercial and sites The XAS solution is well suited to installa where access to the monitored areas is restricted and tamper proof and unobtrusive detection The flexible installation options allow it to mount out the protected area and makes it ideal for use in appli such as the following correctional facilities HVAC ducts XAS System is compatible with the Gamewell FCI Listed ASD PL2F photo detector cable tunnels elevator machine rooms vaults it Works XAS Systems actively draw air from the protected through sampling holes in a pipe network Sampled is then filtered before it is analyzed by conventional or point detectors that are incorporated in the sys The XAS System is available with one inlet pipe or two inlet pipes XAS 2 It can be used with one two detectors per system A number of different points a range of leading technology providers may be systems use a high performance aspirator and pro flow monitoring circuitry Air flow level is dis on a ten element bar graph that can be adjusted for and low flow thresholds The flow failure is reported a device fault sent via relays to the monitoring system Strategies systems may be configured for a number of detection including the following single or dual addressable area detection coincident or double knock detection detection Installer specified point detectors feature offer the benefits simplifying the configuration providing a cost effective solution circumstances where the premises are already pro by point detectors the XAS System is easily intro onto the existing fire alarm control panel signaling by installing equivalent detectors into the system Subject to XAS system approval for the installed spot point detector is a registered trademark of Underwriter Laboratories Inc GAMEWELL FCI are for information only are not intended for installation purposes and are subject to change without notice No responsibility is assumed by Gamewell FCI for their use Rev A page 1 of 2 Clintonville Road Northford CT 06472 1610 USA Tel 203 484 7161 Fax 203 484 7118 by Honeywell International Inc All rights reserved Configuration Options configuration options are available for the XAS 1 XAS 2 Systems XAS 1 System one or two spot point detectors inlet XAS 2 System two spot point detectors dual inlet XAS 1 Systems with one spot point detector are of providing single area detection but XAS 1 and Systems with two detectors are able to provide a of detection strategies Table 1 describes the rec programming configuration options to fit the detection strategy when the two spot point are installed into an XAS System XAS 2 Addressable Areas OR Double Knock v AND v AND OR v Subject to local codes and standards OR AND represents the suggested boolean logic for two detectors to achieve detection strategy 1 Two Detectors Strategy 1 illustrates the dimensions for the XAS 1 and Detectors 1 or 2 analog addressable or spot point detectors in mounting base max VDC nominal Voltage that spot point detectors are powered from the Sig Line Circuit SLC or Initiating Device Circuit IDC mA max 680 mA WHD 10.2 in x 12.6 in x 6.5 in mm x 321 mm x 166 mm XAS 1 XAS 2 Conditions to Ambient Air Inlet Pipe Metric American Pipe Flexible tubing Network Pipe Length Flexible Tube Length Rating Enclosure Monitoring and Control Pressure Outputs XAS 1 XAS 2 Wiring Screw Terminals lbs 3.3 kg lbs 3.4 kg to 131 10 to 55 to 100 0 to 38 to 140 20 to 60 to 95 RH non condensing both metric and American pipe sizes 1.05 in in I D 21mm in O D 19mm to 164 ft 50 m total per device 50 ft 15m Wiring Enclosure filter filter optional and Low programmable flow programmable speeds Pa fault relay output fault relay outputs to 10 AWG 0.9 to 5.5 sq mm solid to 12 AWG 0.6 to 3.5 sq mm 1 Dimensions Rev A page 2 of 2 Clintonville Road Northford CT 06472 1610 USA Tel 203 484 7161 Fax 203 484 7118