Gamewell-FCI XP Mod RSI-95 Releasing Solenoid Interface

File Preview
File Preview
Click below to download for free

File Data

Name gamewell-fci-xp-mod-rsi-95-releasing-solenoid-interface-9413827650.pdf
Type PDF
Size 654.19 KB
Downloads

Text Preview

RSI 95 Solenoid Interface Gamewell FCI 600 Series analog addressable Fire Control Panel FACP will provide all of the required to control the releasing of bulk fire suppressant The Gamewell FCI 600 Series analog address FACPs are currently listed for NFPA 13 Sprinkler 15 Water Spray NFPA 11 Low Expansion Foam 16 Water Foam NFPA 17 Dry Chemical and NFPA Clean Agent types of suppressant The Gamewell Releasing Solenoid Interface RSI 95 is an intelligent interface for the remote control and supervi of activation solenoids used in releasing applications Releasing Solenoid Interface RSI 95 is an address Releasing Service Module providing intelligent analog control functionality complete with full sole supervision and transient voltage suppression Only RSI 95 can be used to actuate the releasing solenoid RSI 95 is automatically bypassed during a Smart or circuit initialization to prevent accidental dis during the generic configuration should inputs be activated analog addressable RSI 95 solenoid control module is for use with any 600 Series FACP To avoid fire suppressant release the RSI 95 assembly the ONLY assembly to be used to provide remote releas solenoid control The circuit can control up to two amps DC power to the solenoid The RSI 95 is powered and via the analog addressable signaling line circuit the solenoid power is obtained from the control panel a UL Listed fire protection 24 VDC power supply The fully supervises the releasing solenoid Guideline the RSI 95 according to NFPA 70 NEC 760 and applicable local codes Only one each RSI 95 and solenoid may be con together for each releasing circuit The RSI 95 is to fit on a 4.688 11.908 cm by 2.125 5.397 deep electrical box user supplied is a trademark of Honeywell International Inc with the Gamewell FCI 600 Series analog fire alarm control panels full solenoid supervision voltage suppression Mounts in its own unique base bypass at system start up A of DC power for solenoid of Suppressants NFPA 13 Sprinkler NFPA 15 Water Spray NFPA 11 Low Expansion NFPA 16 Water Foam NFPA 17 Dry Chemical NFPA 2001 Clean Agent NOTE Releasing systems must be designed by qualified personnel ISO 9000 2000 Company are for information only are not intended for installation purposes and are subject to change without notice No responsibility is assumed by Gamewell FCI for their use Clintonville Road Northford CT 06472 1610 USA Tel 203 484 7161 cid 129 Fax 203 484 7118 Honeywell International Inc All rights reserved Rev A page 1 of 2 Guideline Continued Information assembly consists of an RSM 95 addressable Releasing Service and integral SID Solenoid Interface RSM 95 and SID no longer available trim ring for RSM 95 addition of the trim ring P N 70839 allows flush instal The total voltage drop from the power supply to the of the solenoid circuit shall not exceed two volts The must have its address programmed before the sys will operate correctly the system wiring to the four position terminal L1 L2 P1 P2 per wiring diagram A W532 1 Con the solenoid device wiring to the four position terminal per wiring diagram A W572 Maximum L1 L2 loop resistance should not more than 25 ohms wiring connections should be made while the system is 0 to 49 32 to 120 and or and Current Current Circuit non condensing VDC from analog addressable VDC from UL Listed power mA mA solenoid load A power limited steady 10.16 cm 4.688 11.908 cm electrical box Rev A page 2 of 2 Clintonville Road Northford CT 06472 1610 USA cid 129 Tel 203 484 7161 cid 129 Fax 203 484 7118

Related Files