System Sensor CO1224 4-wire system-monitored carbon monoxide detector

File Preview
File Preview
Click below to download for free

Text Preview

CO1224 Monoxide Sensor CO1224 provides early warning when electrochemical sensing technology accurately carbon monoxide levels in the air monoxide is an odorless colorless tasteless and highly gas that is produced when fuels such as wood gasoline and oil are burned with insufficient air The majority of and commercial fatalities caused from these fuels come heating systems power tools and charcoal grills carbon monoxide is detected the CO1224 will alert residents by and flashing a temp 4 signal alarm Because the CO1224 a 12 24 volt detector with monitoring capabilities protection is 24 7 by a central station regardless of whether residents away from home sleeping or already suffering from the effects CO CO1224 is specifically designed for system operation This means the detector is fully listed to UL 2075 offering a trouble relay as as SEMS terminals for wiring supervision If a problem arises with detector sensor or if the detector has reached its maximum the trouble relay will alert the control panel which will the central station The CO1224 also offers the lowest current in the industry And when the time comes to mount the versatile mounting options are available for the wall ceiling single gang electrical box compliance with UL 2075 trouble relay supervision with SEMS terminals six year end of life timer VDC current draw of 20mA in standby and 40mA in alarm mounting for wall and ceiling sensing technology Listings Specifications monoxide detector shall be a System Sensor model number CO1224 listed to Underwriters Laboratories UL 2075 for Gas and Vapor Detectors and The detector shall be equipped with a sounder and a trouble relay The detector base shall be able to mount to a single gang electrical box or direct mount to the wall or ceiling Wiring connections shall be made by means of SEMS screws The detector shall provide dual color LED indication which to indicate normal standby alarm or end of life When the sensor supervision is in a trouble condition the detector shall send a trouble signal to the When the detector gives a trouble or end of life signal the detector shall be replaced VDC dB in alarm mA mA 75 mA test A 30 VDC A 30 VDC 5.1 Width 3.3 Height 1.3 oz 40 C 32 104 F 90 RH 22 AWG back box surface mount to wall or ceiling Specifications Voltage Signal Current Alarm Current Contact Ratings Contact Ratings Specifications Weight Temperature Range Humidity Range Terminals Modes 1 minute in 4 in 4 Feature Feature Timer Pushing the Test Hush button will silence the for 5 minutes When the sensor supervision is in a trouble the detector will send a trouble signal the panel When the sensor inside the detector has reached end of its life the sounder will sound once minute This will indicate that it is time to the detector An electrochemical carbon detector lifespan is approximately six Information No volt 4 wire system monitored carbon monoxide detector Ohio Avenue St Charles IL 60174 800 SENSOR2 Fax 630 377 6495 System Sensor specifications subject to change without notice Visit systemsensor com for product information including the latest version of this data sheet 9 06 1654

Related Files