Hochiki FIRENET Plus 03-2010

File Preview
File Preview
Click below to download for free

File Data

Name hochiki-firenet-plus-03-2010-0458713962.pdf
Type PDF
Size 666.32 KB
Downloads

Text Preview

FireNET Plus 1127 ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL for a total of 254 points possible per loop design using Hochiki advanced DCP for fast communication SLC loops digital alarm communicator DACT with ID and SIA reporting formats sensitivity levels by device Verification feature daily calibration drift compensation routine 8 line x 40 character LCD display 320 char or 2 loop option FEATURES Up to 127 sensors modules plus 127 analog sounder Uses standard wire no shielded or twisted pair required RS 485 bus for panel network option Network Capability of up to 64 panels option RS 232 interface for programming via a PC on board programmable Form C relays rated at 1 amp 30VDC auxiliary power outputs each rated 360mA at 24 VDC Explorer Windows configuration utility feature network wide software zones in help and alarm information screens on board Class B style Y NAC circuits rated at 2.3 each Special Application and 1.6 amps each continuous Gentex System Sensor Wheelock and Amseco NAC protocol built in day night sensitivity modes Drill test function Walk Test function versatile Cause Effect wizard including Effect action function configuration mode configuration LISTINGS 864 Local Signaling Unit Automatic manual sprinkler supervisory Station and Central Service DACT signaling 70 72 13 Compliant 3038713 Fire 7165 0410 180 on back latest revision at www hochiki com FireNET Plus 1127 series control panel is an addressable fire alarm panel with build options 1 or 2 SLC loops a Digital Alarm Transmitter DACT and an RS 485 for network communication Each SLC loop 127 devices of any combination sensors or and 127 analog sounder bases for a total of 254 points per loop Communication devices is accomplished by use of standard shielded or twisted pair is not required Each includes a 4 amp power supply and has 2 on NAC circuits The RS 485 bus provides to the panel network while another bus provides communication for peripheral The RS 232 interface allows the convenience programming via a PC The system will support a of Hochiki devices photo ion and heat which contain a unique patented sensor incorporating automatic drift compensation and sensitivity modes Additional devices contact monitors relay controllers supervised output and short circuit isolator modules In interfaces to conventional detection systems be established by using a conventional zone module The Loop Explorer Windows interface provides the installer with fingertip to installation programming and diagnostic An Auto Learn feature offers the convenience quick start applications Add to this a reputation high quality and dedicated service which makes an exceptional product both in performance and subject to change without notice America Corporation Village Drive Suite 100 Buena Park CA 90621 2268 714 522 2246 Fax 714 522 2268 Support 800 845 6692 or technicalsupport hochiki com AC DC Supply Current loops per loop per panel 800 addresses sub addresses max per panel Outputs 2.1 Amps 50 60hz or 220VAC 1.1Amps 50 60hz 5.25 Amps Amp integrated Amps max W x 19 H x 3.5 D lbs without batteries optional charcoal enclosure line x 40 character LCD 320 characters total RS485 ports 64 panels max network wide software zones per system or 2 class A style 6 or 7 or class B style 4 sensors modules plus 127 analog sounder bases 254 total SLC COMPATIBLE DEVICES SYSTEM ACCESSORIES class B 2.3 Amps special application Amps Regulated continuous Form C 1 Amp 30VDC outputs 360mA 24VDC each ID and SIA PANEL EXPANDERS One Loop Expansion Card Interface Card Channel Input Output Board LCD Annunciator Display LOOP DEVICES Addressable Photoelectric Sensor Addressable Ionization Sensor Addressable Heat Sensor inch Sensor Base inch Sensor Base Sounder Base Addressable Duct Detector Unit Addressable Duct Detector Unit with relays Test Station for DH98AR Monitoring Module mini w terminal blocks Monitoring Module mini w pigtail leads Monitoring Module with faceplate indicating LED A Contact Monitoring Module FRCMA I has Built in SCI Input Monitor Module with faceplate indicating LED Zone Module Relay Module Relay Module R2ML I R2MH I has Built in SCI Output Module A Supervised Output Module SOM AI has Built in SCI Circuit Isolator Module Manual Pull Station Held Programmer portable device addresser Enclosure houses up to 33AH size batteries Trim Ring for Panel Flush Mount Outputs Power Port Printer Formats MODEL ALK V MS RA R FRCMA I Series SOM AI Series America Corporation FireNET Plus ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL subject to change without notice

Related Files