Hochiki FNV-DP
File Preview
Click below to download for free
Click below to download for free
File Data
Name | hochiki-fnv-dp-1674853029.pdf |
---|---|
Type | |
Size | 768.63 KB |
Downloads |
Text Preview
Features Multiplex 6 Channel Distributed Audio Fire Phone Area of Rescue Fan Damper Control capability System components added as needed 2 Channel Digital Message Repeater Microphone Page to any zone RS 485 Communication Protocol Supervised Installation and Operation Sound Voice Recordings in Alarm and Alert Signals to 4 Minute Message Capacity with 12VDC or 24VDC Fire Alarm Panel with Analog Addressable and based Fire Alarm Panels Minute Message Restart on Microphone Key in the USA Hochiki FNV High Rise Evacuation System in conjunction with the Fire Alarm Control FACP in a building to provide automatic to life safety emergencies The Hochiki FNV includes all necessary features provide an effective voice evacuation system Hochiki FNV can be custom configured to the needs of any high rise application Fire department authorities can easily take of evacuation or relocation procedures emergencies Building management and fire can monitor and control emergency even before the professionals arrive FNV system includes capacity for 6 channels simultaneous audio This provides for stay in place or other public address and automatic messages Fighter Phones or Warden Stations may be as required Area of Rescue stations can handicapped occupants that help is on way Smoke control stair pressurization and shutdown can be completely automatic controlled manually by management or fire Rise Voice Evacuation System Panel 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 2 3 2 3 Configuration System Includes Distributed Panel FNV DP 4 Output Zones may be configured for 8 Dual Channel Audio Interface Dual Single Channel Amplification Options 25 50 100W Dual Channel 25 50 100 200W Single Channel Optional Integrated Fire Phone 4 Circuits expandable to 8 or 12 Area of Rescue Fan and Damper system control System Configuration Up to 256 Distributed Panels FNV DP Village Drive Suite 100 Buena Park CA 90621 2268 714.522.2246 www hochiki com Circuits 2 3 4 2 3 4 2 3 4 FIG 2 FOR FPI TO MBR CONNECTION DETAIL FIG 3 FOR AMI TO AMPLIFIER CONNECTION DETAIL Panel Detail 2 3 4 2 3 4 EOLR 2 3 2 3 PIN RIBBON PIN RIBBON to MBR Connection to Amplifier Connection left side right side PIN RIBBONS PIN RIBBON MBR J7 J7 side plugs MBR 2nd on right side plugs MBR 1st on right AMI card provides audio and control to two modules or amplifier Maximum configuration 5 AMI cards in each FNV DP modules would mount in cabinets FNV DP panel may up to 4 FPI cards for max of 16 phone circuits FPI cards require FNV FPO for circuit termination Class Speaker Lines Class B may be configured 4 A B circuits 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 Life Safety Speakers connected and powered separately Class Speaker Lines 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 FNV MBK card provides additional speaker circuits be configured as several options Panel Configurations Panel Single Channel 25W Panel Single Channel 50W Panel Single Channel 100W Panel Single Channel 25W Fire Phone Panel Single Channel 50W Fire Phone Panel Single Channel 100W Fire Phone Panel Dual Channel 25W Panel Dual Channel 50W Panel Dual Channel 100W Panel Dual Channel 25W Fire Phone Panel Dual Channel 50W Fire Phone Panel Dual Channel 100W Fire Phone Options Cards may be added as job requirements demand Motherboard Relay Card MBR output 8 Class B or 4 Class A speaker circuits Fire Phone Interface Card Fire Phone Output Card in P panels up to 3 additional cards may be added with additional FNV FPIs for termination Audio Module Interface Card with basic panel additional cards give the ability to control modules or accommodate full 3 channel operation Characteristics Power 120 VAC VDC Battery Power Ratings All Circuits 24VDC Panel mA mA mA mA Alarm mA mA mA mA Bus RS 485 Standard Baud data rate Category 5 cable 5V peak to peak max 50mA max 120 Ohms max imp between panels 1.024MHz Charging Maximum charging current from is 800mA Maximum battery size is 17AHr Maximum battery size is 24AHr Dim 14.5 x 27 x 4 w h d Charcoal Grey std Red optional are subject to change without notice Specifications provided for information only and no responsibility is assumed Hochiki America Inc for their use