Hochiki FNV-MP
File Preview
Click below to download for free
Click below to download for free
File Data
Name | hochiki-fnv-mp-3649817025.pdf |
---|---|
Type | |
Size | 774.36 KB |
Downloads |
Text Preview
Features Multiplex 6 Channel Distributed Audio Fire Phone Area of Rescue Fan Damper Control capability System components added as needed 2 Channel Digital Message Repeater Microphone Page to any zone RS 485 Communication Protocol Supervised Installation and Operation Sound Voice Recordings in Alarm and Alert Signals to 4 Minute Message Capacity with 12VDC or 24VDC Fire Alarm Panel with Analog Addressable and based Fire Alarm Panels Minute Message Restart on Microphone Key in the USA Hochiki FNV High Rise Evacuation System in conjunction with the Fire Alarm Control FACP in a building to provide automatic to life safety emergencies The Hochiki FNV includes all necessary features provide an effective voice evacuation system Hochiki FNV can be custom configured to the needs of any high rise application Fire department authorities can easily take of evacuation or relocation procedures emergencies Building management and fire can monitor and control emergency even before the professionals arrive FNV system includes capacity for 6 channels simultaneous audio This provides for stay in place or other public address and automatic messages Fighter Phones or Warden Stations may be as required Area of Rescue stations can handicapped occupants that help is on way Smoke control stair pressurization and shutdown can be completely automatic controlled manually by management or fire Rise Voice Evacuation System Panel CONTROL Configuration System Includes Master Panel FNV MP Master Mic Control 16 Switch Control points Dual Channel DMR High Speed communication loop Optional Integrated Master Fire Phone Area of Rescue Fan and Damper system control System Configuration Up to 1000 monitor and control points Village Drive Suite 100 Buena Park CA 90621 2268 714.522.2246 www hochiki com MP64 P Panel Cable Connection Detail Pin Ribbon Pin Ribbon Pin Ribbon Pin Ribbon Pin Ribbon mounted to plate inside of cabinet mounted on hinged front panel shown are on the back of the the Master Panel system components are mounted to a removable back plate The door and front panel are This enables field wiring to be installed cleanly to the User Interface components Switch LED banks Mic System control and Master Fire Phone accomplished with ribbon cables The front panel mounts separately on a continuous hinge so once installed access for system programming is easily accommodated Loop Wiring Style 4 FROM LAST PANEL TO MASTER TO FIRST DISTRIBUTED PANEL FROM PREVIOUS PANEL Bus Optional wiring for Style 7 supervision 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 PANEL PANEL Loop Wiring Style 7 Communication Bus Communication Bus 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 PANEL PANEL redundant loop must be run in separate conduit minimum spacing from the primary Check local requirements Panel Configurations Panel 16 Switch Control Panel 32 Switch Control Panel 48 Switch Control Panel 64 Switch Control Panel 80 Switch Control Panel 96 Switch Control Panel 16 Switch Control Master Fire Phone Panel 32 Switch Control Master Fire Phone Panel 48 Switch Control Master Fire Phone Panel 64 Switch Control Master Fire Phone Panel 80 Switch Control Master Fire Phone Panel 96 Switch Control Master Fire Phone Options Cards may be added as job requirements demand Master Fire Phone system to incorporate 2 way communication with P panels Switch Scan Card Switch LED Card Input Interface Card in basic panels up to 7 additional cards may be Switch LED Bank up to 8 per FNV SSC included with basic panel additional cards give 16 control Characteristics Power 120 VAC VDC Battery Power Ratings All Circuits 24VDC Panel mA mA mA mA 6 mA mA mA mA mA mA mA 6 mA mA mA Bus RS 485 Standard Baud data rate Category 5 cable 5V peak to peak max 50mA max 120 Ohms max imp between panels 1.024MHz Dim 14.5 x 27 x 4 w h d Charcoal Grey standard Red optional are subject to change without notice Specifications provided for information only and no responsibility is assumed Hochiki America Inc for their use